

Catalogue reference: US-55131
The Lees Bronchus Slight Angle Clamp is a specialized thoracic surgical instrument designed for controlled manipulation and clamping of bronchial structures. Its slight angled profile and DeBakey-type 1 x 2 toothed jaws provide secure tissue engagement during delicate pulmonary procedures.
Prefer Wise or bank transfer? Choose it at checkout.
The Lees Bronchus Slight Angle Clamp DeBakey Type 1 x 2 Teeth is a specialized thoracic surgical instrument designed for controlled manipulation, positioning, and clamping of bronchial and related soft-tissue structures. Its slightly angled configuration provides a practical approach to the operative field, while the DeBakey-type 1 x 2 toothed jaw pattern is designed to provide controlled engagement with tissue. Bronchial surgery requires instruments that provide secure handling while allowing the surgeon to maintain precise control around delicate anatomical structures. The Lees Bronchus Clamp is designed for this type of application, combining a narrow working profile with an angled jaw orientation. The slight angle can facilitate positioning when direct access to the target structure is limited by surrounding anatomy or the geometry of the surgical field. The defining feature of this instrument is its DeBakey-type 1 x 2 teeth . This configuration provides a controlled interlocking grip intended to help stabilize tissue during manipulation. Unlike a completely smooth jaw, the toothed pattern can provide additional purchase on appropriate tissue structures. Because bronchial and pulmonary tissues are delicate, the clamp should be applied with appropriate surgical technique and only as required for the intended procedure. The slight-angle design provides improved working orientation compared with a completely straight clamp in selected thoracic applications. It allows the jaws to approach the target structure at a modest angle while keeping the handles positioned for convenient manipulation. This can support access and visibility during procedures involving the bronchus, pulmonary structures, and adjacent thoracic anatomy. The Lees Bronchus Clamp may be incorporated into thoracic, pulmonary, and cardiothoracic surgical instrument sets . It can be useful during selected procedures involving bronchial handling, tissue retraction, temporary control, and surgical exposure. The exact use should be determined by the operating surgeon based on the patient’s anatomy and the specific surgical technique. For dependable professional performance, the instrument is typically manufactured from surgical-grade stainless steel . Stainless steel offers the mechanical strength required for controlled tissue handling while providing resistance to corrosion when the instrument is appropriately cleaned and maintained. Precision manufacturing also supports accurate jaw alignment and reliable mechanical operation. The clamp’s ring-style handles allow controlled opening and closing of the jaws. A locking mechanism, where present in the instrument configuration, can help maintain the selected clamping position during the procedure. Proper handling is important because toothed jaws can exert concentrated pressure on tissue if excessive force is applied. The instrument is designed for reusable surgical applications and should be carefully reprocessed after each procedure. Cleaning should begin promptly after use to prevent blood and tissue material from drying on the instrument. Particular attention should be given to the 1 x 2 toothed jaws, hinge, and locking mechanism , where biological debris may collect. After cleaning, the instrument should be rinsed, dried, inspected, and sterilized using a validated process appropriate for reusable surgical instruments. Regular inspection is important for maintaining reliable function. Surgical staff should check the teeth for deformation or damage, verify jaw alignment, inspect the hinge for smooth movement, and confirm that any locking mechanism operates correctly. Instruments with damaged teeth, corrosion, excessive wear, or mechanical defects should be removed from clinical use and evaluated by qualified instrument-service personnel. Overall, the Lees Bronchus Slight Angle Clamp DeBakey Type 1 x 2 Teeth is a purpose-oriented thoracic surgical clamp designed for controlled bronchial and soft-tissue handling. Its slight-angle profile, DeBakey-style toothed jaws, durable stainless steel construction, and precise operating characteristics make it a useful component of specialized thoracic and cardiothoracic surgical instrument sets. Key Features Specialized Lees Bronchus Clamp for thoracic surgical applications Slight-angle profile for improved operative positioning DeBakey-type 1 x 2 toothed jaw configuration Designed for controlled bronchial and soft-tissue manipulation Suitable for thoracic and cardiothoracic procedures Toothed jaws provide secure tissue engagement Ring handles support controlled instrument manipulation Precision jaw alignment for dependable handling Surgical-grade stainless steel construction Durable and corrosion-resistant with proper maintenance Suitable for reusable professional surgical instrumentation Designed for validated cleaning and sterilization procedures Product Specifications Specification Details Product Name Lees Bronchus Slight Angle Clamp Instrument Type Bronchial / Thoracic Surgical Clamp Jaw Pattern DeBakey Type 1 x 2 Teeth Jaw Configuration Toothed Profile Slightly Angled Primary Function Bronchial & Tissue Manipulation Surgical Specialty Thoracic & Cardiothoracic Surgery Handle Type Ring Handle Material Surgical-Grade Stainless Steel Application Bronchial and Pulmonary Procedures Reusable Yes, with appropriate reprocessing Sterilization Validated surgical instrument sterilization methods Intended Users Qualified Surgical Professionals FAQs 1. What is the Lees Bronchus Clamp used for? The Lees Bronchus Clamp is designed for controlled manipulation, positioning, and clamping of bronchial and related soft-tissue structures during appropriate thoracic surgical procedures. 2. What does DeBakey 1 x 2 teeth mean? A DeBakey 1 x 2 configuration refers to a toothed jaw pattern in which one jaw has a single tooth that engages with two corresponding teeth on the opposing jaw, providing controlled tissue purchase. 3. Why is the Lees Bronchus Clamp slightly angled? The slight angle helps provide a more favorable approach to bronchial structures in selected thoracic operative fields and may improve positioning around surrounding anatomy. 4. Is this clamp suitable for thoracic surgery? Yes. The instrument is specifically designed for thoracic applications and may be incorporated into pulmonary and cardiothoracic surgical instrument sets. 5. What material is the Lees Bronchus Clamp made from? The instrument is specified as being manufactured from surgical-grade stainless steel , supporting durability and corrosion resistance with proper care. 6. Are the DeBakey teeth atraumatic? The DeBakey-style tooth pattern is intended to provide controlled tissue engagement, but toothed jaws can exert concentrated pressure. The instrument should therefore be used with appropriate surgical technique and only for suitable tissue handling. 7. Is the Lees Bronchus Clamp reusable? Yes. It is intended for reusable professional surgical use when appropriate cleaning, inspection, maintenance, and validated sterilization procedures are followed.
| Instrument name | Lees Bronchus Slight Angle Clamp DeBakey Type 1 x 2 Teeth |
|---|---|
| Catalogue reference | US-55131 |
| Category | Dental Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.