

Catalogue reference: US-72564
The Long Posterior Band Removing Pliers 678-207 are specialized orthodontic pliers designed for controlled removal of compatible posterior orthodontic bands. Their extended working configuration provides additional reach and access when working around molars and other difficult-to-reach posterior teeth.
Prefer Wise or bank transfer? Choose it at checkout.
The Long Posterior Band Removing Pliers 678-207 are precision orthodontic instruments designed to facilitate the controlled removal of posterior orthodontic bands. The long configuration provides additional reach into posterior areas of the mouth, making the instrument particularly useful when access around molars or other posterior teeth is limited. Orthodontic bands are commonly used on posterior teeth as part of fixed appliance systems. At the completion of treatment, during appliance modification, or when a band needs to be replaced, controlled removal is required. The 678-207 Long Posterior Band Removing Pliers provide a dedicated instrument for engaging compatible bands and applying controlled mechanical force during the removal process. The extended working profile can help the clinician reach posterior bands while maintaining a suitable hand position outside the immediate treatment area. This can be especially useful when the patient’s cheek, tongue, adjacent teeth, archwire, brackets, or other appliance components restrict access. The working jaws are designed to engage the compatible band securely. Once appropriate engagement has been established, the clinician can perform controlled movements according to the selected orthodontic technique. Proper positioning is essential because excessive or poorly directed force may place unnecessary stress on the tooth, surrounding tissues, or orthodontic appliance. The Long Posterior Band Removing Pliers 678-207 can be incorporated into a comprehensive orthodontic instrument setup alongside short posterior band removing pliers, band seating pliers, band crimping pliers, crown and band contouring pliers, Weingart pliers, Howe pliers, and other appliance adjustment instruments. Compared with shorter band removing instruments, the long configuration provides additional working reach and can offer improved access in selected posterior applications. The appropriate instrument should be selected according to tooth position, band design, patient anatomy, and the clinician’s preferred technique. The pliers are typically manufactured from durable medical-grade or surgical-grade stainless steel. This construction provides the rigidity required for controlled band manipulation and supports repeated professional use when proper cleaning, sterilization, and maintenance procedures are followed. Precision jaw alignment is important for reliable band engagement. The working end should be inspected regularly for wear, deformation, corrosion, or misalignment. Any instrument with compromised working surfaces should be evaluated before further clinical use. The long working profile should be used with controlled pressure rather than as a means of applying excessive leverage. Posterior band removal should be performed with appropriate visualization and technique, taking into consideration the condition of the tooth, cement interface, band design, and surrounding structures. After each clinical procedure, the 678-207 Long Posterior Band Removing Pliers should undergo appropriate infection-control processing. Blood, saliva, cement residue, and other contaminants should be removed according to the dental facility’s validated cleaning procedure. The instrument should then be rinsed, thoroughly dried, inspected, packaged, and sterilized using a validated process compatible with the instrument and manufacturer’s recommendations. Careful storage is also important for maintaining the long working end. The jaws should be protected from impact and contact with other instruments that could cause bending or deformation. Routine inspection and maintenance help preserve accurate band engagement and extend instrument service life. The Long Posterior Band Removing Pliers 678-207 combine extended reach, controlled band engagement, and durable orthodontic construction. They are a practical addition to professional orthodontic instrument sets for posterior band removal and fixed appliance management. Key Features Professional Long Posterior Band Removing Pliers 678-207 Designed for posterior orthodontic band removal Extended working profile for increased reach Facilitates access around posterior teeth and molars Precision jaws for controlled band engagement Suitable for compatible orthodontic bands Supports controlled fixed appliance removal Useful in restricted posterior intraoral areas Helps maintain a controlled hand position during band removal Durable medical-grade or surgical-grade stainless steel construction Ergonomic design for precise manipulation Reusable professional orthodontic instrument Product Specifications Specification Details Product Name Long Posterior Band Removing Pliers Reference 678-207 Instrument Type Orthodontic Band Removing Pliers Profile Long / Extended Primary Function Posterior Band Removal Applications Molar Band Removal, Fixed Appliance Removal Specialty Orthodontics Working End Precision Band-Engaging Jaws Construction Medical-Grade / Surgical-Grade Stainless Steel Reusable Yes Sterilization According to Validated Clinical Protocols Band Compatibility According to Manufacturer Specification Intended Users Orthodontists, Dentists, Dental Professionals FAQs What are Long Posterior Band Removing Pliers 678-207 used for? The 678-207 pliers are designed to assist with controlled removal of compatible orthodontic bands from posterior teeth, including molar areas. What is the advantage of the long design? The extended configuration provides additional reach, which can make it easier to access posterior bands when the working area is difficult to reach. Are these pliers suitable for molar bands? Yes, they are designed for appropriate posterior band removal, including compatible molar bands. What is the difference between the long and short posterior band removing pliers? The long version provides additional working reach, while a shorter version may offer a more compact profile for certain clinical access requirements. What is the reference number? The reference number is 678-207 . What material are these orthodontic pliers made from? They are typically manufactured from durable medical-grade or surgical-grade stainless steel, depending on the manufacturer’s specifications. Can the 678-207 be sterilized? Yes. As a reusable orthodontic instrument, it should be cleaned, inspected, dried, packaged, and sterilized according to validated clinical procedures and manufacturer recommendations. How should the working jaws be maintained? The jaws should be inspected for alignment, wear, corrosion, and deformation. Proper cleaning and careful storage help maintain reliable band engagement. Can these pliers be used to remove brackets? They are primarily intended for posterior band removal. Dedicated bracket removing pliers should be used for orthodontic bracket removal. Who should use Long Posterior Band Removing Pliers? They are intended for trained orthodontists, dentists, and qualified dental professionals performing appropriate orthodontic band removal procedures.
| Instrument name | Long Posterior Band Removing Pliers 678-207 |
|---|---|
| Catalogue reference | US-72564 |
| Category | Dental Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.