

Catalogue reference: US-31383
Angled Bipolar Loop Electrode is a precision electrosurgical instrument designed for controlled tissue resection, bipolar coagulation, and effective hemostasis during endoscopic and minimally invasive procedures. Featuring an angled loop configuration and bipolar energy delivery, this reusable and autoclavable instrument provides enhanced access, improved visualization, and reduced lateral thermal spread.
Prefer Wise or bank transfer? Choose it at checkout.
Angled Bipolar Loop Electrode is a specialized electrosurgical instrument commonly used by urologists, gynecologists, and endoscopic surgeons during procedures requiring precise tissue excision and controlled coagulation. The instrument is specifically designed to deliver bipolar electrical energy through a loop-shaped electrode, enabling simultaneous tissue cutting and coagulation. Bipolar current flows only between the active electrode surfaces, helping minimize thermal spread and reduce the risk of unintended injury to adjacent tissues. Featuring a precision-engineered angled loop design, the electrode provides improved access to anatomically challenging areas and enhances visualization within confined operative spaces. The angled configuration facilitates accurate tissue engagement and controlled resection, particularly in procedures requiring access around curved or difficult-to-reach structures. The integrated bipolar design supports effective hemostasis throughout tissue excision, helping maintain a clear operative field and reducing the need for additional coagulation instruments. Angled Bipolar Loop Electrodes are compatible with appropriate bipolar electrosurgical generators and endoscopic systems. Depending on the specific design, they may be used with dedicated resectoscopes, handpieces, or endoscopic instruments. Manufactured from premium medical-grade conductive materials with high-performance insulating components, these electrodes offer exceptional durability, dependable conductivity, and consistent electrosurgical performance. The low-glare finish minimizes reflections under endoscopic visualization systems while facilitating efficient cleaning and maintenance. Widely used in hospitals, ambulatory surgical centers, and specialty clinics, Angled Bipolar Loop Electrodes are essential components of modern endoscopic electrosurgical systems. Fully reusable and autoclavable, these electrodes are designed to withstand repeated cleaning and sterilization cycles while maintaining structural integrity, loop geometry, insulation quality, and reliable electrical performance. Common Clinical Applications Include: Transurethral Procedures Endoscopic Tissue Resection Urological Surgery Gynecological Procedures Hysteroscopic Surgery Minimally Invasive Surgery Tissue Excision Bipolar Coagulation Hemostasis Endoscopic Electrosurgery Specifications Feature Details Product Name Angled Bipolar Loop Electrode Instrument Type Bipolar Electrosurgical Electrode Function Tissue Cutting and Bipolar Coagulation Electrode Design Angled Loop Configuration Energy Type Bipolar Electrosurgery Compatibility Compatible Bipolar Generators and Endoscopic Systems Application Endoscopic and Minimally Invasive Procedures Material Medical-Grade Conductive Materials with Insulated Components Finish Low-Glare Finish Sterilization Fully Sterilizable and Autoclavable Reusability Reusable Performance Enhanced Access and Precise Tissue Resection with Reduced Thermal Spread Frequently Asked Questions What is an Angled Bipolar Loop Electrode used for? It is used for tissue cutting, controlled tissue resection, bipolar coagulation, and hemostasis during endoscopic procedures. What are the advantages of the angled loop design? The angled configuration improves access to difficult-to-reach anatomical areas and enhances visualization during tissue resection. How does bipolar energy improve surgical safety? Bipolar energy confines electrical current between the active electrode surfaces, helping reduce thermal spread to surrounding tissues. Which specialties commonly use Angled Bipolar Loop Electrodes? They are commonly used in urology, gynecology, and other endoscopic surgical specialties. Are Angled Bipolar Loop Electrodes compatible with all generators? Compatibility depends on the connector configuration, instrument system, and electrosurgical generator specifications. Is the Angled Bipolar Loop Electrode autoclavable? Yes. It is designed to withstand repeated cleaning and autoclave sterilization cycles. Can the Angled Bipolar Loop Electrode be reused? Yes. It is engineered for repeated clinical use when properly cleaned, sterilized, and maintained according to manufacturer instructions.
| Instrument name | Angled Bipolar Loop Electrode |
|---|---|
| Catalogue reference | US-31383 |
| Category | Electrosurgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.