ENT Instruments

10″ Jackson “velvet eye” Asp Tube 4.0mm

Catalogue reference: US-42484

$60.00$42.00✓ In Stock

With its tissue-friendly tip and precision suction flow, the Jackson Velvet Eye 10″ Aspiration Tube is the preferred tool for safe, atraumatic airway management.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 10″ Jackson “Velvet Eye” Aspiration Tube 4.0mm is a specialized surgical suction instrument widely used in ENT and airway management procedures where controlled suction, tissue safety, and consistent visibility are essential. Designed with a 10-inch working length, this Jackson aspiration tube provides optimal balance between reach and maneuverability. It is particularly suitable for moderate-depth surgical fields, including ENT procedures involving the nasal cavity, oral cavity, and upper airway structures. The compact length allows surgeons to maintain excellent control during delicate suctioning tasks. The 4.0mm diameter provides efficient suction capacity while maintaining precise control over fluid removal. It is ideal for aspirating blood, mucus, secretions, and irrigation fluids without compromising visibility in the surgical field. This ensures continuous clarity during procedures where precision is critical. The defining feature of this instrument is the “velvet eye” design, which refers to smooth, rounded side openings engineered to reduce tissue trauma and prevent mucosal injury. These atraumatic aspiration ports allow gentle and consistent suction while minimizing the risk of tissue being drawn into the openings. This design significantly improves patient safety and surgical efficiency in sensitive anatomical regions. Constructed from high-quality medical-grade stainless steel, the instrument ensures durability, corrosion resistance, and long-term performance under repeated sterilization cycles. The smooth internal lumen promotes uninterrupted suction flow and reduces the risk of clogging, ensuring reliable performance throughout surgical procedures. The 10″ Jackson Velvet Eye Aspiration Tube is commonly used in ENT surgeries such as airway suctioning, nasal procedures, and laryngeal interventions. It is also valuable in tracheostomy care and other airway management procedures where safe and efficient aspiration is required. Its ergonomic design provides comfortable handling and stable control during use. Surgeons benefit from reduced hand fatigue and improved precision, particularly during procedures requiring continuous suction. The atraumatic construction further enhances safety when working near delicate mucosal tissues. The 10″ Jackson Velvet Eye Aspiration Tube 4.0mm combines precision engineering, atraumatic design, and reliable suction performance, making it an essential instrument in modern ENT and airway surgical practice. Key Features 10″ length for balanced surgical reach and control 4.0mm diameter for efficient suction flow Velvet eye side ports for atraumatic suction Smooth edges reduce tissue trauma risk Ideal for ENT and airway procedures High-quality stainless steel construction Corrosion-resistant and durable design Smooth internal lumen for consistent suction Minimizes clogging during procedures Ergonomic handling for surgeon comfort Ensures clear surgical field visibility Suitable for repeated sterilization Product Specifications Specification Details Product Type Surgical Aspiration Tube Application ENT, Airway Management Material Medical-grade stainless steel Finish Polished Atraumatic Velvet Eye Sterilization Autoclavable Reusability Reusable Specialty Atraumatic suction (Velvet Eye design) Instrument Type Jackson Aspiration Tube Usage Removal of blood, mucus, and secretions Product Contents 1 x 10″ Jackson Velvet Eye Aspiration Tube 4.0mm Applications ENT surgical procedures Airway suctioning and management Nasal and oral cavity surgeries Laryngeal procedures Tracheostomy care General surgical aspiration use FAQs Q1: What is the Jackson Velvet Eye Aspiration Tube used for? It is used for controlled suction of fluids and secretions in ENT and airway procedures. Q2: What is the benefit of the velvet eye design? It provides smooth side openings that reduce tissue trauma during suction. Q3: What does 4.0mm indicate? It refers to the internal diameter, ensuring balanced suction flow and control. Q4: Is this instrument reusable? Yes, it is reusable and designed for standard sterilization processes. Q5: Why is the 10″ length important? It offers optimal control and maneuverability in moderate-depth surgical fields. Q6: In which surgeries is it commonly used? It is commonly used in ENT, airway management, tracheostomy care, and nasal procedures.

Instrument name10″ Jackson “velvet eye” Asp Tube 4.0mm
Catalogue referenceUS-42484
CategoryENT Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image