

Catalogue reference: US-42972
Combining control and efficiency, this Dissector Suction simplifies surgical navigation with precise fluid removal and gentle tissue handling in a single, reliable instrument.
Prefer Wise or bank transfer? Choose it at checkout.
The Single Use Dissector Suction 12Fr 13cm Polished Tip is a specialized surgical instrument designed to combine gentle tissue dissection with continuous suction in a single efficient tool. It is widely used in ENT, oral, and general surgical procedures where precise tissue handling and clear visibility are essential for safe and effective surgical outcomes. This instrument is commonly used in the field of Otolaryngology as well as in oral and maxillofacial surgery and minor general surgical procedures. It is particularly useful in operations such as septoplasty, tonsillectomy, nasal surgeries, and other delicate procedures requiring controlled dissection with simultaneous fluid removal. The 12Fr suction size provides balanced fluid evacuation capacity, making it suitable for moderate suction needs while maintaining precision. It allows efficient removal of blood and irrigation fluids without compromising tissue integrity or obstructing the surgical field. With a 13cm length , the instrument offers excellent maneuverability and control in shallow to mid-depth surgical areas. This length provides surgeons with stable handling and precise access, making it ideal for confined anatomical spaces where accuracy is critical. The polished tip design is engineered for smooth and atraumatic tissue interaction. It facilitates gentle dissection while minimizing trauma to surrounding structures. The polished finish ensures smooth movement within tissues and enhances surgical precision during delicate procedures. As a single-use sterile instrument , it ensures maximum infection control by eliminating cross-contamination risks. Each unit is pre-sterilized and ready for immediate use, making it ideal for modern operating rooms focused on patient safety and efficiency. Manufactured from high-quality medical-grade materials, the instrument provides reliable structural integrity and consistent suction performance. The internal lumen is designed for smooth and uninterrupted fluid flow, reducing clogging and maintaining efficient surgical workflow. The instrument is fully compatible with standard hospital suction systems, ensuring secure connection and stable performance during procedures. Its lightweight and ergonomic design enhances handling comfort and reduces surgeon fatigue during extended operations. Overall, the Single Use Dissector Suction 12Fr 13cm Polished Tip is an essential disposable surgical instrument that combines precision dissection and suction in one efficient design. It is widely used in ENT and surgical specialties for improving visibility, control, and procedural efficiency. Key Features 12Fr balanced suction capacity for controlled fluid removal 13cm length for precise surgical handling Polished tip for atraumatic tissue dissection Single-use sterile design for infection control Combines dissection and suction in one instrument Ideal for ENT and general surgical procedures Smooth internal lumen for consistent suction flow Lightweight and ergonomic design Compatible with standard suction systems Enhances surgical visibility and precision Reduces need for multiple instruments Reliable performance in delicate procedures Product Specifications Specification Details Product Type Single Use Dissector Suction Application ENT & General Surgery Material Medical-grade surgical material Size 12 Fr Length 13 cm Tip Design Polished Dissector Tip Sterilization Single Use, Pre-sterilized Reusability Disposable Specialty Dissection + Suction Instrument Instrument Type Dissector Suction Usage Tissue dissection and fluid removal Product Contents 1 x Single Use Dissector Suction 12Fr 13cm Polished Tip Applications ENT surgical procedures Septoplasty Tonsillectomy Nasal and sinus surgery Oral and maxillofacial procedures Minor general surgery Tissue dissection with suction control Maintenance of clear operative field FAQs 1. What is a dissector suction used for? It is used to gently dissect tissues while simultaneously removing blood and fluids during surgery. 2. What does 12Fr mean? It indicates a medium suction size suitable for controlled fluid evacuation. 3. What is the benefit of a polished tip? It allows smooth, atraumatic tissue handling during dissection. 4. Is this instrument reusable? No, it is a single-use sterile instrument designed for one-time use. 5. What is the purpose of 13cm length? It provides controlled access for shallow to mid-depth surgical procedures. 6. Is it used in ENT surgery? Yes, it is commonly used in ENT and nasal surgical procedures. 7. Does it improve surgical efficiency? Yes, it combines dissection and suction, reducing the need for multiple instruments
| Instrument name | Single Use Dissector Suction 12fr 13cm Polished Tip |
|---|---|
| Catalogue reference | US-42972 |
| Category | ENT Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.