

Catalogue reference: US-24404
Chang Phaco Chopper is a precision ophthalmic microsurgical instrument designed for nucleus chopping, fragmentation, and manipulation during phacoemulsification cataract surgery. Featuring a distinctive Chang micro-finger style tip, slim microsurgical shaft, and ergonomic handle, this reusable and autoclavable instrument provides controlled nucleus division, efficient lens disassembly, and exceptional surgical precision during advanced cataract procedures. The Chang design is widely associated with horizontal chopping techniques in modern cataract surgery.
Prefer Wise or bank transfer? Choose it at checkout.
Chang Phaco Chopper is a specialized ophthalmic surgical instrument used during phacoemulsification cataract surgery to facilitate controlled fragmentation and disassembly of the crystalline lens nucleus. Designed for advanced cataract surgery techniques, the instrument features a curved micro-finger style chopping tip with a defined inner cutting edge , enabling surgeons to engage the lens nucleus and create controlled cleavage planes during nucleus fragmentation procedures. This design is particularly suited for horizontal chopping techniques and precise nuclear segmentation. The instrument works in conjunction with the phacoemulsification handpiece to mechanically divide the nucleus into smaller fragments that can be emulsified and aspirated more efficiently. Controlled fragmentation helps improve surgical efficiency and facilitates cataract removal through small-incision techniques. The curved tip geometry allows surgeons to maneuver around the nuclear equator while maintaining precise control during chopping procedures. The defined inner edge assists in creating accurate fracture lines and controlled separation of nuclear material. Its slim low-profile shaft provides smooth insertion through small corneal incisions and excellent visualization under the operating microscope. The streamlined design supports delicate intraocular maneuvers while minimizing obstruction within the surgical field. The ergonomic handle offers superior balance, tactile feedback, and maneuverability, allowing surgeons to perform advanced chopping techniques with confidence and precision. Chang Phaco Choppers are commonly used during phacoemulsification cataract surgery, horizontal chop techniques, nucleus fragmentation, lens disassembly, dense cataract management, and advanced anterior segment procedures. Manufactured from premium surgical-grade stainless steel, the instrument offers exceptional durability, corrosion resistance, and dependable long-term performance. The satin or matte low-glare finish minimizes reflections under microscope illumination and ophthalmic surgical lighting. Available in multiple tip profiles, shaft lengths, angles, and handle configurations, Chang Phaco Choppers can be selected according to surgeon preference and surgical technique. Widely used in hospitals, ophthalmic surgery centers, eye clinics, and ambulatory surgical facilities, the Chang Phaco Chopper is an essential component of modern cataract surgery instrument sets. Fully reusable and autoclavable, the instrument is designed to withstand repeated cleaning and sterilization cycles while maintaining tip precision, alignment, and structural integrity. Common Clinical Applications Phacoemulsification Cataract Surgery Horizontal Chop Technique Nucleus Fragmentation Lens Disassembly Dense Cataract Management Nuclear Segmentation Cataract Extraction Procedures Anterior Segment Surgery Lens Nucleus Manipulation Ophthalmic Microsurgery Specifications Feature Details Product Name Chang Phaco Chopper Instrument Type Ophthalmic Nucleus Fragmentation Instrument Function Lens Nucleus Chopping and Fragmentation Working End Design Chang Micro-Finger Chopper Tip Tip Configuration Curved Finger-Shaped Tip with Defined Inner Edge Tip Function Nucleus Engagement, Division, and Manipulation Shaft Design Slim Microsurgical Shaft Handle Design Ergonomic Microsurgical Handle Material Surgical-Grade Stainless Steel Finish Satin or Matte Low-Glare Finish Available Configurations Multiple Tip Styles, Angles, Lengths, and Handle Designs Available Sterilization Fully Sterilizable and Autoclavable Reusability Reusable Application Cataract and Anterior Segment Surgery Frequently Asked Questions What is a Chang Phaco Chopper used for? It is used to divide, fragment, and manipulate the lens nucleus during phacoemulsification cataract surgery. What is the advantage of the Chang micro-finger design? The curved finger-shaped tip with a defined inner edge facilitates controlled nucleus engagement and efficient horizontal chopping techniques. Which procedures commonly use a Chang Phaco Chopper? It is commonly used in phacoemulsification cataract surgery, horizontal chop techniques, nucleus fragmentation procedures, and dense cataract management. Which medical specialties commonly use this instrument? It is primarily used in ophthalmology, particularly in cataract and anterior segment microsurgery. Are different configurations available? Yes. Chang Phaco Choppers are available in multiple tip profiles, shaft lengths, angles, and handle configurations to accommodate various surgical techniques and surgeon preferences. Is the Chang Phaco Chopper autoclavable? Yes. It is fully sterilizable and designed to withstand repeated autoclave sterilization cycles. Is this instrument reusable? Yes. The instrument is reusable and engineered for repeated cleaning, sterilization, and long-term professional use.
| Instrument name | Chang Phaco Chopper |
|---|---|
| Catalogue reference | US-24404 |
| Category | Eye Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.