Catalogue reference: US-23569
Simcoe Cannula is a specialized ophthalmic irrigation and aspiration instrument designed for the controlled removal of cortical material and residual lens matter during cataract surgery. Featuring a fine cannula tip and dual-function irrigation-aspiration design, this reusable and autoclavable instrument provides efficient fluid management, precise tissue removal, and reliable performance in anterior segment procedures.
Prefer Wise or bank transfer? Choose it at checkout.
Simcoe Cannula is a widely used ophthalmic surgical instrument designed for manual irrigation and aspiration (I/A) during cataract surgery and other anterior segment procedures. The instrument is specifically engineered to facilitate the removal of residual cortical material, lens fragments, viscoelastic substances, and other intraocular debris following lens extraction. Its dual-function design combines irrigation and aspiration capabilities, allowing surgeons to maintain anterior chamber stability while efficiently clearing the surgical field. The fine atraumatic cannula tip enables precise access to the capsular bag and surrounding structures while helping minimize trauma to delicate ocular tissues. Controlled irrigation supports chamber maintenance, while aspiration assists in the safe removal of residual lens material. Simcoe Cannulas are commonly used during extracapsular cataract extraction (ECCE), manual small incision cataract surgery (MSICS), phacoemulsification procedures, pediatric cataract surgery, and other lens-related interventions. The lightweight design provides excellent tactile feedback and allows surgeons to perform delicate intraocular maneuvers with precision and control. Manufactured from premium surgical-grade stainless steel, the instrument offers exceptional durability, corrosion resistance, and dependable long-term performance. The smooth polished surface facilitates cleaning and maintenance while supporting optimal fluid flow characteristics. Available in multiple tip sizes, angles, and configurations, Simcoe Cannulas can be selected according to surgical technique and procedural requirements. Widely used in hospitals, ophthalmic surgery centers, eye clinics, and ambulatory surgical facilities, the Simcoe Cannula remains an essential instrument in cataract surgery and anterior segment ophthalmology. Fully reusable and autoclavable, the instrument is designed to withstand repeated cleaning and sterilization cycles while maintaining structural integrity, tip precision, and fluid-flow performance. Common Clinical Applications Cataract Surgery Phacoemulsification Procedures Extracapsular Cataract Extraction (ECCE) Manual Small Incision Cataract Surgery (MSICS) Cortical Cleanup Residual Lens Material Removal Viscoelastic Removal Pediatric Cataract Surgery Anterior Segment Surgery Ophthalmic Microsurgery Specifications Feature Details Product Name Simcoe Cannula Instrument Type Ophthalmic Irrigation and Aspiration Cannula Function Irrigation and Aspiration of Lens Material Design Dual-Function Irrigation/Aspiration System Tip Design Fine Atraumatic Cannula Tip Fluid Management Controlled Irrigation and Aspiration Material Surgical-Grade Stainless Steel Construction Precision Ophthalmic Design Finish Smooth Polished Finish Available Configurations Multiple Tip Sizes and Angles Available Sterilization Fully Sterilizable and Autoclavable Reusability Reusable Application Cataract and Anterior Segment Surgery Frequently Asked Questions What is a Simcoe Cannula used for? It is used for irrigation and aspiration of cortical material, residual lens fragments, and viscoelastic substances during cataract surgery. What is the advantage of the dual-function design? The instrument provides simultaneous irrigation and aspiration, helping maintain chamber stability while removing surgical debris. Which procedures commonly use a Simcoe Cannula? It is commonly used in cataract surgery, ECCE, MSICS, phacoemulsification, pediatric cataract surgery, and anterior segment procedures. Which medical specialties commonly use this instrument? It is primarily used in ophthalmology, particularly in cataract and anterior segment surgery. Are different tip configurations available? Yes. Simcoe Cannulas are available in multiple tip sizes, lengths, and angled configurations to suit different surgical requirements. Is the Simcoe Cannula autoclavable? Yes. It is fully sterilizable and designed to withstand repeated autoclave cycles. Is this instrument reusable? Yes. The instrument is reusable and engineered for repeated cleaning, sterilization, and long-term professional use.
| Instrument name | Simcoe Cannula |
|---|---|
| Catalogue reference | US-23569 |
| Category | Eye Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.