

Catalogue reference: US-60649
The 12″ Fitzgerald Aortic Aneurysm Clamp Curved Jaws is a specialized vascular surgical instrument designed for controlled clamping and manipulation of appropriate vascular structures during aortic and aneurysm procedures. Its 12-inch length and curved jaw configuration provide extended reach and controlled positioning within the operative field.
Prefer Wise or bank transfer? Choose it at checkout.
The 12″ Fitzgerald Aortic Aneurysm Clamp Curved Jaws is a specialized cardiovascular surgical instrument designed for controlled manipulation and temporary clamping of appropriate vascular structures during aortic, aneurysm, and vascular procedures. Its Fitzgerald-style design combines an extended 12-inch length with curved jaws, providing useful reach and a controlled approach to vascular structures within deeper operative fields. The 12-inch overall length provides surgeons with extended working reach while maintaining practical instrument control. This can be particularly useful during cardiovascular and thoracic procedures where vascular structures may be located deeper within the operative site. The longer profile allows the surgeon to position the clamp at an appropriate working distance while maintaining direct control over the instrument during placement and manipulation. A primary feature of this instrument is its curved jaw configuration . Curved jaws can facilitate access around anatomical structures and provide an alternative approach compared with straight vascular clamps. The curved profile allows the instrument to be positioned according to the anatomy and operative technique, supporting controlled engagement of the intended vascular structure. Proper placement and pressure remain essential because vascular tissues require careful and atraumatic handling. The Fitzgerald Aortic Aneurysm Clamp is intended for use by trained cardiovascular and vascular surgical professionals. It may be incorporated into aortic surgery instrument sets, cardiovascular surgical trays, vascular surgery sets, aneurysm repair instrument collections, and thoracic surgical instrument systems . The specific clinical application should always be determined by the operating surgeon according to the patient’s anatomy, procedure requirements, and established surgical technique. The curved jaw design can be particularly useful when access to the target vessel requires a controlled angled approach. It supports positioning around suitable anatomical structures while providing the surgeon with a stable instrument interface. Because the instrument is intended for vascular applications, excessive force should be avoided, and the clamp should only be applied to structures for which its design is appropriate. The 12-inch length also contributes to the instrument’s usefulness in deeper surgical fields. It offers additional reach without requiring the surgeon to place the hand directly adjacent to the operative site. This can assist with controlled manipulation during complex cardiovascular procedures and makes the clamp a practical component of specialized vascular instrument inventories. When supplied as a reusable surgical instrument, the Fitzgerald Aortic Aneurysm Clamp should be carefully processed after each use. Prompt cleaning and thorough decontamination are important for removing biological material from the curved jaws, hinge, and other working surfaces. The instrument should then be inspected for proper jaw alignment, smooth opening and closing, structural integrity, and visible signs of wear or damage before sterilization. Sterilization should be performed using a validated method consistent with the healthcare facility’s established procedures and applicable manufacturer instructions. Proper handling, storage, and maintenance help preserve the clamp’s mechanical function and extend its service life. Instruments should always be inspected before use to verify that they remain suitable for the intended surgical application. For hospitals, cardiovascular operating rooms, vascular surgeons, surgical centers, and medical instrument suppliers, the 12″ Fitzgerald Aortic Aneurysm Clamp with Curved Jaws offers a specialized solution for controlled vascular handling. Its extended 12-inch reach and curved jaw profile make it a practical addition to professional aortic, aneurysm, cardiovascular, and vascular surgical instrument sets . Key Features 12-inch Fitzgerald aortic aneurysm clamp Specialized curved jaw configuration Designed for controlled vascular clamping and manipulation Extended length provides useful reach in deeper operative fields Suitable for appropriate aortic and aneurysm procedures Curved jaws support controlled positioning around anatomical structures Designed for cardiovascular and vascular surgical applications Provides practical maneuverability during complex operative procedures Suitable for aortic and cardiovascular surgical instrument sets Durable surgical construction for professional operating-room use Requires appropriate cleaning, inspection, and sterilization Intended for use by trained surgical professionals Product Specifications Specification Details Product Name Fitzgerald Aortic Aneurysm Clamp Length 12″ Jaw Design Curved Jaws Instrument Type Aortic Aneurysm Clamp Design Fitzgerald Style Primary Application Cardiovascular and Vascular Surgery Intended Use Controlled Vascular Clamping and Manipulation Working Profile Curved Jaw Configuration Construction Surgical Instrument Reusable According to product configuration and manufacturer guidance Sterilization According to validated facility protocol and manufacturer instructions Intended Users Trained Cardiovascular and Vascular Surgical Professionals FAQs 1. What is a 12″ Fitzgerald Aortic Aneurysm Clamp used for? The instrument is designed for controlled manipulation and temporary clamping of appropriate vascular structures during aortic, aneurysm, cardiovascular, and vascular surgical procedures. 2. What is the benefit of curved jaws on this aortic aneurysm clamp? The curved jaws can facilitate positioning around suitable anatomical structures and provide a controlled approach when a curved working profile is preferred. 3. Why is this Fitzgerald clamp 12 inches long? The 12-inch length provides extended reach, which can be useful when accessing vascular structures located deeper within the operative field. 4. Is the Fitzgerald Aortic Aneurysm Clamp suitable for cardiovascular surgery? Yes. It is designed for appropriate cardiovascular, vascular, aortic, and aneurysm-related applications requiring controlled vascular manipulation by trained surgical professionals. 5. Can this Fitzgerald clamp be sterilized? When supplied as a reusable surgical instrument, it should be cleaned, decontaminated, inspected, and sterilized according to validated healthcare-facility procedures and applicable manufacturer instructions. 6. How should the curved jaws be maintained? The curved jaws should be thoroughly cleaned after use and inspected for alignment, surface damage, wear, and smooth mechanical operation before sterilization and reuse. 7. What surgical sets can include this 12″ Fitzgerald clamp? This clamp can be included in appropriate aortic surgery sets, cardiovascular instrument sets, vascular surgery trays, aneurysm surgery sets, and thoracic surgical instrument collections.
| Instrument name | 12″ Fitzgerald Aortic Aneurysm Clamp Curved Jaws |
|---|---|
| Catalogue reference | US-60649 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.