

Catalogue reference: US-59632
The 235mm Safe Jaw Aortic Aneurysm Clamp is a specialized cardiovascular surgical instrument designed for controlled clamping of suitable aortic and vascular structures. Its 235mm length and safe-jaw configuration support precise positioning and controlled handling during appropriate aortic procedures.
Prefer Wise or bank transfer? Choose it at checkout.
The 235mm Safe Jaw Aortic Aneurysm Clamp is a specialized aortic aneurysm surgical clamp designed for controlled temporary clamping and manipulation of suitable vascular structures during appropriate cardiovascular and aortic surgical procedures. With an overall length of 235mm and a specialized safe-jaw configuration, this instrument provides surgical teams with a dedicated option for controlled vascular access and handling. Aortic aneurysm clamps are specialized instruments used during selected cardiovascular procedures where temporary control of an appropriate portion of the aorta or related vascular anatomy is required. By providing controlled clamping, the instrument can help the surgical team manage blood flow while carrying out the intended intervention. Exact application, positioning, pressure, and duration should always be determined by the operating surgeon according to the patient’s anatomy and established surgical technique. The 235mm overall length provides useful reach for cardiovascular procedures where access to deeper vascular structures may be required. An appropriately proportioned clamp allows the surgeon to position the working end while maintaining controlled hand placement outside the immediate operative area. The length should be selected according to the surgical approach, anatomy, and requirements of the specific procedure. The Safe Jaw configuration is a defining feature of this instrument. The jaw design is intended to provide controlled contact with suitable vascular structures while supporting careful surgical manipulation. Because the aorta and other major vessels are delicate anatomical structures, correct instrument selection and controlled application are essential. The clamp should never be applied with excessive force or used outside its intended purpose. This aortic aneurysm clamp can be incorporated into cardiovascular surgical instrument sets, aortic surgery trays, vascular reconstruction sets, thoracic surgery collections, and specialized aneurysm instrument systems . It can complement other cardiovascular instruments such as aortic forceps, vascular scissors, vessel dilators, vascular needle holders, retractors, and additional aortic clamps. The instrument’s dedicated configuration can help surgical teams maintain an organized selection of vascular clamps for different procedures. Different clamp lengths and jaw designs may be selected according to anatomical access, vessel dimensions, and operative requirements. The 235mm configuration provides a defined option for teams requiring extended instrument reach. Controlled handling is particularly important during aortic procedures. Improper placement, excessive compression, or inappropriate duration of application can potentially cause vascular or tissue injury. The instrument should therefore only be used by qualified surgical professionals familiar with the relevant procedure and appropriate vascular clamping technique. Before each procedure, the Safe Jaw Aortic Aneurysm Clamp should be carefully inspected for alignment, mechanical operation, jaw condition, and structural integrity. The jaws should remain properly aligned and free from deformation, surface damage, or excessive wear that could interfere with intended performance. For reusable configurations, thorough cleaning and decontamination should be performed promptly following each procedure according to validated healthcare-facility instrument-processing procedures. Particular attention should be given to the jaw surfaces, hinge, and other mechanical areas where biological material may accumulate. After cleaning, the instrument should be inspected again for proper mechanical function and structural condition. Sterilization should be performed using a validated method appropriate for the instrument and consistent with applicable manufacturer instructions and institutional protocols. Proper cleaning, sterilization, handling, and storage help maintain the clamp’s performance and service life. For hospitals, cardiovascular surgeons, vascular surgeons, thoracic surgical teams, operating rooms, and medical instrument suppliers, the 235mm Safe Jaw Aortic Aneurysm Clamp provides a specialized solution for controlled aortic clamping. Its 235mm length and safe-jaw configuration make it a practical addition to professional cardiovascular and aortic surgical instrument collections. Key Features Aortic aneurysm clamp design 235mm overall length Safe-jaw configuration Designed for controlled aortic clamping Suitable for appropriate cardiovascular procedures Intended for selected aortic and vascular applications Extended length provides practical surgical reach Supports controlled positioning of the working end Suitable for aortic surgery instrument sets Designed for professional surgical handling Specialized configuration for vascular procedures Requires proper cleaning, inspection, sterilization, and storage Product Specifications Specification Details Product Name Safe Jaw Aortic Aneurysm Clamp Instrument Type Aortic Aneurysm Clamp Overall Length 235mm Jaw Type Safe Jaw Primary Application Aortic Surgery Secondary Application Cardiovascular & Vascular Surgery Intended Use Controlled Aortic Clamping Design Specialized Aortic Clamp Operation Manual Construction Surgical Instrument Sterilization According to validated facility protocol and manufacturer guidance Intended Users Trained Surgical Professionals Clinical Environment Hospitals, Operating Rooms & Surgical Centers FAQs 1. What is a Safe Jaw Aortic Aneurysm Clamp used for? It is designed for controlled temporary clamping and manipulation of suitable aortic or vascular structures during appropriate cardiovascular surgical procedures. 2. What is the length of this aortic aneurysm clamp? This model has a specified 235mm overall length , providing extended reach for appropriate aortic and cardiovascular surgical applications. 3. What does Safe Jaw mean? Safe Jaw refers to the specified jaw configuration of this clamp, designed for controlled contact with appropriate vascular structures. 4. Is this clamp suitable for aortic surgery? It is designed for appropriate aortic and cardiovascular surgical applications and should be used only by trained surgical professionals following established surgical technique. 5. Why is clamp length important in aortic surgery? Instrument length can influence access and hand positioning during procedures involving deeper or less accessible vascular structures. Selection should be based on anatomy and surgical requirements. 6. How should the 235mm Aortic Aneurysm Clamp be sterilized? For reusable configurations, it should be cleaned, decontaminated, inspected, and sterilized using a validated process consistent with manufacturer guidance and healthcare-facility protocols. 7. How should this aortic clamp be maintained? The jaws, hinge, alignment, and overall structure should be inspected after cleaning and before reuse. Any deformation, damage, or mechanical abnormality should be evaluated before clinical application.
| Instrument name | 235mm Safe Jaw Aortic Aneurysm Clamp |
|---|---|
| Catalogue reference | US-59632 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.