Catalogue reference: US-57464
The 5¼″ Cooley Pediatric Clamp Satinsky is a specialized vascular instrument designed for controlled partial occlusion and manipulation of appropriately sized pediatric vessels. Its compact configuration supports precise positioning and access in delicate cardiovascular operative fields.
Prefer Wise or bank transfer? Choose it at checkout.
The 5 1/4″ Cooley Pediatric Clamp Satinsky is a specialized cardiovascular surgical instrument designed for controlled partial occlusion, manipulation, and positioning of appropriately sized vascular structures during selected pediatric procedures. Combining a compact 5¼-inch profile with a Cooley-style Satinsky configuration, this clamp provides a practical solution for vascular applications where controlled access and precise vessel handling are essential. The Satinsky-style configuration is associated with partial or tangential vascular occlusion, allowing selected portions of a vessel to be controlled while maintaining access to the remaining vessel lumen. This type of vascular clamp can be useful during procedures involving vessel repair, reconstruction, or anastomotic techniques where complete interruption of blood flow may not be desirable. The exact application should be determined by the qualified surgical team. The pediatric configuration provides a smaller working profile intended for appropriately sized pediatric vascular structures. Pediatric vessels can be smaller and more delicate than adult vessels, making appropriate instrument selection particularly important. The surgeon should evaluate the patient’s anatomy, vessel dimensions, operative exposure, and procedural requirements before selecting the clamp. At 5¼ inches overall length , the Cooley Pediatric Satinsky Clamp provides a compact and maneuverable profile. Its size allows close control around the operative site while limiting unnecessary instrument bulk. This can be advantageous during delicate pediatric cardiovascular procedures where working space may be restricted and precise positioning is essential. The Cooley-style design is commonly associated with cardiovascular and vascular surgical instrumentation . Depending on the specific configuration, a pediatric Satinsky clamp may assist with controlled partial occlusion of vessels during selected vascular reconstruction, repair, anastomosis, or related procedures. It should be used only according to established surgical technique and by appropriately trained professionals. Controlled handling is especially important when applying a vascular clamp to delicate pediatric structures. The clamp should be positioned accurately and applied with only the force required for the intended clinical purpose. Excessive compression, twisting, or inappropriate leverage may result in tissue trauma or instrument damage. The instrument is typically manufactured from surgical-grade stainless steel , providing strength, durability, and corrosion resistance suitable for professional reusable surgical instrumentation. Precision manufacturing supports reliable working-end alignment and consistent mechanical operation. A smooth finish facilitates cleaning, inspection, and routine maintenance. After use, reusable instruments should be promptly cleaned and decontaminated according to established healthcare-facility protocols. Particular attention should be given to the Satinsky-style working end, jaws, hinge, and adjoining surfaces , where blood and biological material may accumulate. The instrument should be inspected for corrosion, wear, deformation, surface damage, and jaw alignment before sterilization. Sterilization should be performed using a validated method consistent with the manufacturer’s instructions and institutional infection-control requirements. Proper storage and careful handling help preserve the clamp’s working geometry and mechanical integrity. The 5¼″ Cooley Pediatric Clamp Satinsky combines a compact pediatric profile with a specialized Satinsky-style configuration for controlled partial vascular occlusion and manipulation. Its maneuverability, precision-oriented design, and durable construction make it a valuable addition to professional pediatric cardiovascular and vascular surgical instrument sets. Key Features Cooley pattern pediatric Satinsky vascular clamp 5¼-inch overall length Pediatric configuration Satinsky-style partial occlusion design Designed for appropriately sized pediatric vessels Supports controlled partial vascular occlusion Facilitates vessel manipulation and positioning Compact profile for delicate operative fields Suitable for selected pediatric cardiovascular procedures Surgical-grade stainless steel construction Durable design for professional reusable instrumentation Product Specifications Specification Details Product Name Cooley Pediatric Clamp Satinsky Overall Length 5¼″ Configuration Pediatric Clamp Style Satinsky Instrument Type Pediatric Vascular Clamp Primary Function Partial vascular occlusion and vessel manipulation Intended Application Appropriately sized pediatric vascular structures Surgical Specialty Pediatric Cardiovascular / Vascular Surgery Typical Application Vessel control, repair, reconstruction, and manipulation Design Compact Satinsky-style configuration Material Surgical-grade stainless steel Reusable Yes, for reusable models Sterilization Follow validated manufacturer and facility protocols FAQs 1. What is a Cooley Pediatric Satinsky Clamp used for? It is designed for controlled partial occlusion and manipulation of appropriately sized vascular structures during selected pediatric cardiovascular and vascular procedures. 2. What is the length of this pediatric Satinsky clamp? The overall length is 5¼ inches , providing a compact and maneuverable surgical profile. 3. What is the purpose of a Satinsky-style clamp? A Satinsky-style vascular clamp is designed for controlled partial or tangential vessel occlusion, allowing selected portions of a vessel to be controlled while maintaining access to the remaining lumen. 4. Why is the pediatric configuration important? The pediatric configuration provides a working profile intended for appropriately sized pediatric vessels, which require careful instrument selection and controlled application. 5. Which procedures may use a pediatric Satinsky clamp? It may be incorporated into selected pediatric cardiovascular and vascular procedures involving vessel repair, reconstruction, anastomosis, or controlled partial occlusion. 6. What material is the Cooley Pediatric Satinsky Clamp made from? It is typically manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 7. How should this pediatric vascular clamp be maintained? It should be promptly cleaned, thoroughly inspected for residue or damage, and processed according to validated healthcare-facility instrument reprocessing procedures. 8. Can the Cooley Pediatric Satinsky Clamp be sterilized? Reusable models should be cleaned, inspected, and sterilized using a validated process according to the manufacturer’s instructions and healthcare-facility sterilization protocols.
| Instrument name | 5 1/4″ Cooley Pediatric Clamp Satinsky |
|---|---|
| Catalogue reference | US-57464 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.