General Surgery Instruments

5″ Cooley Neonatal Vascular Clamp Angled Shanks Straight Jaws

Catalogue reference: US-57431

$80.00$56.00✓ In Stock

The 5″ Cooley Neonatal Vascular Clamp Angled Shanks Straight Jaws is a specialized vascular instrument designed for controlled manipulation, positioning, and temporary occlusion of appropriately sized neonatal vessels. Its angled shanks and straight jaws provide an offset approach with a direct working surface for precise vascular handling.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 5″ Cooley Neonatal Vascular Clamp Angled Shanks Straight Jaws is a specialized cardiovascular and vascular surgical instrument designed for controlled manipulation, positioning, and temporary occlusion of appropriately sized neonatal vascular structures. Its compact 5-inch length combines angled shanks with straight jaws , creating a specialized working geometry for delicate operative fields where an offset instrument approach and direct jaw contact are beneficial. The angled shank configuration changes the trajectory between the handle and the working end, allowing the surgeon to approach the target vessel from an offset direction. This design can help provide clearance around surrounding anatomical structures while maintaining controlled hand positioning. It may be particularly useful in selected neonatal operative fields where direct access is restricted. The straight jaws provide a direct working surface for controlled engagement of an appropriately sized vessel. Their straight profile offers predictable contact when the target anatomy permits a direct jaw orientation. Combining straight jaws with angled shanks allows the working end to remain straightforward while the instrument body follows an offset path. With an overall length of 5 inches , this Cooley neonatal vascular clamp provides a compact balance between reach and maneuverability. The relatively short profile supports close control around small anatomical structures while reducing unnecessary instrument bulk. This makes the instrument suitable for consideration in specialized neonatal and pediatric cardiovascular instrument sets. The neonatal designation indicates that the clamp is intended for selected applications involving appropriately sized neonatal vascular structures. Neonatal vessels can be small and delicate, making proper instrument selection essential. The surgeon should evaluate vessel size, patient anatomy, surgical exposure, and procedural requirements before selecting the instrument. A neonatal vascular clamp may be used when temporary localized control of blood flow is required. Depending on the specific surgical procedure, it may assist with vessel isolation, positioning, repair, reconstruction, or other techniques requiring controlled vascular occlusion. The exact clinical indication and application should be determined by qualified surgical professionals. The combination of angled shanks and straight jaws provides a practical balance between offset access and direct working-end geometry. The angled shanks can help keep the handle away from the immediate surgical site, while the straight jaws provide a defined interface for appropriate vascular manipulation. This configuration may improve maneuverability in selected confined operative fields. The instrument is typically manufactured from surgical-grade stainless steel , providing strength, durability, and corrosion resistance appropriate for professional reusable surgical instrumentation. Precision manufacturing supports reliable jaw alignment and consistent mechanical performance. A smooth surface finish facilitates routine cleaning, inspection, and maintenance. Careful application is essential when using vascular clamps around delicate neonatal anatomy. The jaws should be accurately positioned and applied with only the force required for the intended clinical purpose. Excessive compression, twisting, bending, or inappropriate leverage should be avoided to help minimize the potential for tissue trauma and instrument deformation. Following use, reusable instruments should be promptly cleaned and decontaminated according to established healthcare-facility procedures. Particular attention should be given to the straight jaws, angled shanks, hinge, and adjoining working surfaces , where blood and biological residue may accumulate. The instrument should be inspected for corrosion, wear, deformation, surface damage, and jaw alignment before sterilization. Sterilization should be performed using a validated method consistent with the manufacturer’s instructions and institutional infection-control requirements. Proper storage and careful handling help preserve the angled shank geometry, straight jaw alignment, and overall mechanical integrity. The 5″ Cooley Neonatal Vascular Clamp Angled Shanks Straight Jaws combines a compact neonatal profile with angled shanks and a direct straight jaw configuration. Its specialized geometry, maneuverability, and durable construction make it a practical addition to professional neonatal and pediatric cardiovascular and vascular surgical instrument collections. Key Features Cooley pattern neonatal vascular clamp 5-inch overall length Angled shank configuration Straight jaw design Designed for appropriately sized neonatal vessels Supports controlled temporary vascular occlusion Provides an offset approach to the operative site Straight jaws offer a direct working surface Compact profile for delicate neonatal operative fields Facilitates controlled vessel manipulation and positioning Surgical-grade stainless steel construction Product Specifications Specification Details Product Name Cooley Neonatal Vascular Clamp Overall Length 5″ Shank Configuration Angled Jaw Configuration Straight Configuration Neonatal Instrument Type Vascular Clamp Primary Function Temporary vascular occlusion and vessel manipulation Intended Application Appropriately sized neonatal vascular structures Surgical Specialty Neonatal / Pediatric Cardiovascular and Vascular Surgery Typical Application Vessel control, positioning, isolation, and manipulation Design Angled shanks with straight jaws Material Surgical-grade stainless steel Reusable Yes, for reusable models Sterilization Follow validated manufacturer and facility protocols FAQs 1. What is a Cooley Neonatal Vascular Clamp used for? It is designed for controlled manipulation, positioning, and temporary occlusion of appropriately sized neonatal vascular structures during selected vascular and cardiovascular procedures. 2. What is the overall length of this Cooley clamp? The overall length is 5 inches , providing a compact and maneuverable surgical profile. 3. What is the benefit of angled shanks? Angled shanks create an offset trajectory between the handle and working end, which can facilitate access around surrounding anatomy. 4. What type of jaws does this model have? This model features straight jaws , providing a direct working surface for appropriate vascular applications. 5. Is this clamp intended for neonatal vascular surgery? It is designed for selected applications involving appropriately sized neonatal vascular structures. Suitability should be confirmed according to the patient’s anatomy and surgical requirements. 6. Can this clamp be used for temporary vascular occlusion? Yes. It is designed to support temporary vascular occlusion when appropriate for the target vessel and surgical technique. 7. What material is the Cooley Neonatal Vascular Clamp made from? It is typically manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 8. Can this neonatal vascular clamp be sterilized? Reusable models should be cleaned, inspected, and sterilized using a validated process according to the manufacturer’s instructions and healthcare-facility sterilization protocols.

Instrument name5″ Cooley Neonatal Vascular Clamp Angled Shanks Straight Jaws
Catalogue referenceUS-57431
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image