General Surgery Instruments

5″ Cooley Neonatal Vascular Clamp Carotid Clamp

Catalogue reference: US-57449

$80.00$56.00✓ In Stock

The 5″ Cooley Neonatal Vascular Clamp Carotid Clamp is a specialized vascular instrument designed for controlled manipulation and temporary occlusion of appropriately sized carotid vessels. Its compact neonatal profile supports precise handling in delicate vascular operative fields.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 5″ Cooley Neonatal Vascular Clamp Carotid Clamp is a specialized cardiovascular and vascular surgical instrument designed for controlled manipulation, positioning, and temporary occlusion of appropriately sized carotid vascular structures during selected neonatal procedures. Its compact 5-inch overall length provides a practical combination of reach and maneuverability for delicate operative fields where precise instrument placement is essential. The instrument is specifically described as a neonatal carotid vascular clamp , making appropriate sizing particularly important when working with small and delicate vascular anatomy. Neonatal vessels require careful handling and accurate instrument selection. The clamp should therefore be selected according to the patient’s anatomy, vessel dimensions, surgical exposure, and established procedural requirements. A vascular clamp of this type may be used when temporary localized control of blood flow is required. Depending on the surgical technique, it can assist with vessel isolation, positioning, repair, reconstruction, or other procedures requiring controlled vascular occlusion. The exact clinical application should be determined by the qualified surgical team. The Cooley design is associated with cardiovascular and vascular surgical instrumentation intended for precise handling of blood vessels. This neonatal configuration provides a compact working profile that can help facilitate controlled access around smaller anatomical structures. The instrument’s 5-inch length can provide close control without the excessive reach or bulk associated with longer vascular clamps. The carotid application makes controlled positioning particularly important. The clamp should be placed according to established surgical technique and used only when its configuration and dimensions are appropriate for the target vessel. Excessive compression, prolonged application, twisting, or inappropriate manipulation should be avoided to reduce the risk of vascular tissue injury and instrument damage. The compact design can make this instrument suitable for specialized neonatal cardiovascular, vascular, and pediatric surgical instrument sets . Its intended use should always be determined by trained clinicians based on the patient’s individual anatomy and the requirements of the procedure. The instrument is typically manufactured from surgical-grade stainless steel , offering mechanical strength, durability, and corrosion resistance suitable for professional reusable surgical instrumentation. Precision manufacturing supports dependable working-end alignment and consistent mechanical performance. A smooth surface finish also assists with routine cleaning, inspection, and maintenance. Proper instrument care is important for maintaining performance. Following use, reusable instruments should be promptly cleaned and decontaminated according to established healthcare-facility procedures. Particular attention should be given to the working jaws, hinge, and adjoining surfaces , where blood and biological residue can accumulate. After cleaning, the clamp should be carefully inspected for corrosion, wear, deformation, surface damage, or jaw misalignment. Any instrument showing mechanical defects should be evaluated according to the healthcare facility’s instrument-management procedures before further use. Sterilization should be performed using a validated method compatible with the manufacturer’s instructions and institutional infection-control requirements. Proper storage and handling help preserve the working-end geometry and extend the service life of the instrument. The 5″ Cooley Neonatal Vascular Clamp Carotid Clamp combines a compact neonatal configuration with a specialized carotid vascular application. Its 5-inch length, maneuverable profile, and durable construction make it a useful addition to professional neonatal and pediatric cardiovascular surgical instrument sets where appropriately sized vascular control is required. Key Features Cooley pattern neonatal vascular clamp 5-inch overall length Designed for carotid vascular applications Neonatal configuration for appropriately sized vessels Supports controlled temporary vascular occlusion Facilitates precise vessel manipulation and positioning Compact profile for delicate operative fields Suitable for selected neonatal cardiovascular procedures Designed for controlled access around small vascular structures Surgical-grade stainless steel construction Durable design for professional reusable instrumentation Product Specifications Specification Details Product Name Cooley Neonatal Vascular Clamp Overall Length 5″ Application Carotid Vascular Clamp Configuration Neonatal Instrument Type Vascular / Carotid Clamp Primary Function Temporary vascular occlusion and vessel manipulation Intended Application Appropriately sized neonatal carotid vessels Surgical Specialty Neonatal / Pediatric Cardiovascular and Vascular Surgery Typical Application Vessel control, isolation, positioning, and manipulation Design Compact neonatal vascular profile Material Surgical-grade stainless steel Reusable Yes, for reusable models Sterilization Follow validated manufacturer and facility protocols FAQs 1. What is a Cooley Neonatal Vascular Clamp used for? It is designed for controlled manipulation, positioning, and temporary occlusion of appropriately sized carotid vascular structures during selected neonatal vascular procedures. 2. What is the overall length of this Cooley clamp? The overall length is 5 inches , providing a compact and maneuverable profile for delicate operative fields. 3. What is a neonatal carotid clamp? A neonatal carotid clamp is a specialized vascular instrument intended for controlled handling and temporary occlusion of appropriately sized carotid vessels in neonatal surgical applications. 4. Why is a neonatal vascular clamp important? Neonatal vessels are small and delicate, so appropriately sized instrumentation can provide more controlled access and handling during specialized vascular procedures. 5. Which procedures may use a carotid vascular clamp? It may be incorporated into selected neonatal and pediatric cardiovascular or vascular procedures requiring temporary carotid vessel control, repair, positioning, or manipulation. 6. What material is the Cooley Neonatal Vascular Clamp made from? It is typically manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 7. How should this carotid clamp be maintained? It should be promptly cleaned after use, thoroughly inspected for biological residue and mechanical damage, and processed according to validated healthcare-facility procedures. 8. Can the Cooley Neonatal Vascular Clamp be sterilized? Reusable models should be cleaned, inspected, and sterilized using a validated process according to the manufacturer’s instructions and institutional infection-control protocols.

Instrument name5″ Cooley Neonatal Vascular Clamp Carotid Clamp
Catalogue referenceUS-57449
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image