

Catalogue reference: US-59048
The 5cm Glover Bulldog Clamp Cvd Jaws 2cm is a compact vascular instrument designed for controlled temporary occlusion and manipulation of appropriately sized blood vessels. Its curved 2cm jaws provide a focused working profile for precise handling in delicate operative fields.
Prefer Wise or bank transfer? Choose it at checkout.
The 5cm Glover Bulldog Clamp Cvd Jaws 2cm is a compact vascular surgical instrument designed for controlled temporary occlusion and manipulation of appropriately sized blood vessels during selected cardiovascular and vascular procedures. With a 5cm overall length and 2cm curved jaws , this Glover Bulldog Clamp provides a specialized working profile for precise vessel handling where compact instrumentation is required. Bulldog clamps are commonly designed for temporary vascular control, allowing a vessel to be occluded locally during selected surgical procedures. The compact design can be particularly useful when the operative field is restricted or when the surgeon requires a small instrument for direct access to an isolated vascular structure. The exact application should be determined by a qualified surgical professional according to the patient’s anatomy and procedural requirements. The curved jaw configuration provides an offset working surface that can facilitate engagement of appropriately positioned vessels. Curved jaws may help the instrument follow the contour or approach of the target vascular structure while maintaining a compact overall profile. The 2cm jaw dimension provides a relatively focused working area, making appropriate sizing important before use. With an overall length of 5cm , this Glover Bulldog Clamp is designed for close, controlled manipulation. Its short profile can help provide direct instrument handling in confined surgical fields while minimizing unnecessary shaft length. This makes it suitable for consideration in specialized cardiovascular and vascular surgical instrument sets where compact vessel-control instrumentation is required. The Glover pattern is associated with vascular and cardiovascular surgical instrumentation intended for controlled handling of blood vessels. This particular configuration combines the compact Bulldog Clamp format with curved jaws, providing a specialized solution for selected temporary occlusion applications. Proper instrument selection is essential when working with delicate vascular structures. The clamp should be selected according to vessel diameter, anatomical location, surgical exposure, and the requirements of the specific procedure. The curved jaws should be positioned accurately around the intended vessel, and the instrument should be applied using only the force necessary for the intended clinical purpose. Excessive compression, twisting, bending, or inappropriate manipulation should be avoided to help minimize the possibility of vascular tissue trauma and preserve instrument integrity. The surgeon should follow established surgical techniques and institutional protocols when applying a vascular clamp. The instrument is typically manufactured from surgical-grade stainless steel , providing mechanical strength, durability, and corrosion resistance suitable for professional reusable surgical instrumentation. Precision manufacturing supports dependable jaw alignment and consistent mechanical action. A smooth surface finish also facilitates routine cleaning, inspection, and maintenance. After use, reusable instruments should be promptly cleaned and decontaminated according to established healthcare-facility procedures. Particular attention should be given to the curved jaws, hinge, and adjoining working surfaces , where blood and biological material may accumulate. The clamp should be inspected for corrosion, wear, deformation, surface damage, and jaw alignment before sterilization. Sterilization should be performed using a validated process compatible with the manufacturer’s instructions and institutional infection-control requirements. Proper storage and careful handling help maintain the curved jaw geometry and mechanical performance over repeated use. The 5cm Glover Bulldog Clamp Cvd Jaws 2cm combines a compact 5cm profile with 2cm curved jaws for controlled vascular handling. Its specialized geometry, small working profile, and durable construction make it a useful addition to professional cardiovascular and vascular surgical instrument collections. Key Features Glover pattern Bulldog vascular clamp 5cm overall length 2cm curved jaws Compact design for confined operative fields Supports controlled temporary vascular occlusion Facilitates precise vessel manipulation and positioning Curved jaws provide an offset working profile Suitable for selected cardiovascular and vascular procedures Focused working-end configuration Surgical-grade stainless steel construction Durable design for professional reusable instrumentation Product Specifications Specification Details Product Name Glover Bulldog Clamp Overall Length 5cm Jaw Configuration Curved Jaw Length 2cm Instrument Type Bulldog / Vascular Clamp Primary Function Temporary vascular occlusion and vessel manipulation Intended Application Appropriately sized vascular structures Surgical Specialty Cardiovascular / Vascular Surgery Typical Application Vessel control, positioning, and temporary occlusion Design Compact curved-jaw configuration Material Surgical-grade stainless steel Reusable Yes, for reusable models Sterilization Follow validated manufacturer and facility protocols FAQs 1. What is a Glover Bulldog Clamp used for? It is designed for controlled temporary vascular occlusion and manipulation of appropriately sized blood vessels during selected vascular and cardiovascular procedures. 2. What is the overall length of this Glover Bulldog Clamp? The overall length is 5cm , providing a compact profile for close instrument control. 3. What is the jaw length? The curved jaws have a specified length of 2cm , providing a focused working area for selected vascular applications. 4. What is the benefit of curved jaws? Curved jaws can provide an offset working profile that facilitates controlled engagement of appropriately positioned vessels. 5. Can a Bulldog Clamp be used for temporary vascular occlusion? Yes. Bulldog clamps are designed for localized temporary vascular control when appropriate for the target vessel and surgical technique. 6. Which procedures may use a Glover Bulldog Clamp? It may be incorporated into selected cardiovascular and vascular procedures requiring temporary vessel control, positioning, or manipulation. 7. What material is the Glover Bulldog Clamp made from? It is typically manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 8. How should the Glover Bulldog Clamp be sterilized? Reusable models should be cleaned, inspected, and sterilized using a validated process according to the manufacturer’s instructions and healthcare-facility sterilization protocols.
| Instrument name | 5cm Glover Bulldog Clamp Cvd Jaws 2cm |
|---|---|
| Catalogue reference | US-59048 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.