

Catalogue reference: US-58406
The 6 1/2″ Dardik Multi Purpose Clamp Angled 30° is a specialized vascular surgical instrument designed for controlled vessel manipulation and temporary occlusion. Its 30° angled configuration provides an offset working approach for precise access in selected operative fields.
Prefer Wise or bank transfer? Choose it at checkout.
The 6 1/2″ Dardik Multi Purpose Clamp Angled 30° is a specialized vascular and cardiovascular surgical instrument designed for controlled manipulation, positioning, and temporary occlusion of appropriately sized vascular structures. With an overall length of 6.5 inches and a 30-degree angled configuration , this clamp provides a practical combination of working reach and directional access for selected vascular procedures. The 30° angled design provides an offset working trajectory between the instrument shaft and working end. This geometry can help the surgeon approach a target vessel from an angled direction while maintaining a comfortable and controlled hand position. It may be particularly useful in operative fields where direct access is limited by surrounding anatomy or by the orientation of the surgical exposure. As a multi-purpose vascular clamp , this instrument may be considered for a variety of procedures requiring controlled vessel manipulation, positioning, isolation, or temporary occlusion. Depending on the specific surgical technique, vascular clamps can assist during vessel repair, reconstruction, anastomosis, or other interventions requiring temporary blood-flow control. The precise indication should always be determined by a qualified surgical professional. The 6.5-inch overall length provides useful reach while retaining maneuverability. Compared with shorter vascular clamps, the additional length can provide practical access to vessels positioned deeper within the operative field. At the same time, the angled working profile helps support controlled positioning without requiring the surgeon to align the entire instrument directly with the target vessel. The 30° configuration offers a moderate angle that can help balance directional access with controlled manipulation. The angled working end may facilitate positioning around anatomical structures and can be advantageous in selected cardiovascular and peripheral vascular procedures. Instrument selection should always take into consideration the patient’s anatomy, target vessel dimensions, surgical exposure, and requirements of the procedure. Controlled application is essential when using any vascular clamp. The working end should be positioned accurately before applying the clamp, and only the force necessary for the intended clinical purpose should be used. Excessive compression, twisting, bending, or inappropriate leverage should be avoided to help minimize the potential for vascular tissue trauma and instrument deformation. The instrument is typically manufactured from surgical-grade stainless steel , providing mechanical strength, durability, and corrosion resistance suitable for professional reusable surgical instrumentation. Precision manufacturing supports reliable alignment and consistent mechanical performance. A smooth finish also assists with routine cleaning, inspection, and maintenance. After use, reusable instruments should be promptly cleaned and decontaminated according to established healthcare-facility procedures. Particular attention should be given to the angled working end, hinge, and adjoining surfaces , where blood and biological material may accumulate. The clamp should be inspected for corrosion, wear, deformation, surface damage, and mechanical alignment before sterilization. Sterilization should be performed using a validated method compatible with the manufacturer’s instructions and institutional infection-control requirements. Proper storage and careful handling help preserve the 30° angled geometry and overall mechanical integrity of the instrument. The 6 1/2″ Dardik Multi Purpose Clamp Angled 30° combines a versatile vascular clamp profile with a 30° angled configuration and useful 6.5-inch working length. Its directional geometry, maneuverability, and durable construction make it a practical addition to professional cardiovascular and vascular surgical instrument sets. Key Features Dardik pattern multi-purpose vascular clamp 6.5-inch overall length 30° angled configuration Designed for controlled vascular manipulation Supports temporary vascular occlusion Facilitates vessel positioning and isolation Angled profile provides directional operative access Useful working length for selected deeper operative fields Suitable for selected cardiovascular and vascular procedures Surgical-grade stainless steel construction Durable design for professional reusable instrumentation Product Specifications Specification Details Product Name Dardik Multi Purpose Clamp Overall Length 6 1/2″ Configuration Angled Angle 30° Instrument Type Multi-Purpose Vascular Clamp Primary Function Vessel manipulation and temporary vascular occlusion Intended Application Appropriately sized vascular structures Surgical Specialty Vascular / Cardiovascular Surgery Typical Application Vessel control, positioning, isolation, repair, and manipulation Design 30° angled vascular configuration Material Surgical-grade stainless steel Reusable Yes, for reusable models Sterilization Follow validated manufacturer and facility protocols FAQs 1. What is a Dardik Multi Purpose Clamp used for? It is designed for controlled manipulation, positioning, isolation, and temporary occlusion of appropriately sized vascular structures during selected surgical procedures. 2. What is the length of this Dardik clamp? The overall length is 6.5 inches , providing useful reach while maintaining practical maneuverability. 3. What does the 30° angled configuration provide? The 30° angle creates an offset working trajectory that can facilitate directional access to selected vessels in confined or anatomically challenging operative fields. 4. Can this Dardik clamp be used for temporary vascular occlusion? Yes. It is designed to support temporary vascular occlusion when appropriate for the target vessel and surgical technique. 5. Why is it called a multi-purpose clamp? Its vascular clamp configuration can be used for various selected applications involving vessel manipulation, positioning, isolation, and temporary control, depending on the surgical procedure. 6. Which specialties may use this vascular clamp? It may be incorporated into selected vascular and cardiovascular surgical instrument sets. 7. What material is the Dardik Multi Purpose Clamp made from? It is typically manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 8. Can the Dardik Multi Purpose Clamp be sterilized? Reusable models should be cleaned, inspected, and sterilized using a validated process according to the manufacturer’s instructions and healthcare-facility sterilization protocols.
| Instrument name | 6 1/2″ Dardik Multi Purpose Clamp Angled 30° |
|---|---|
| Catalogue reference | US-58406 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.