General Surgery Instruments

6″ DeBakey Peripheral Vascular Clamp Curved Jaws

Catalogue reference: US-58229

$80.00$56.00✓ In Stock

The 6″ DeBakey Peripheral Vascular Clamp Curved Jaws is a specialized vascular surgical instrument designed for controlled manipulation, positioning, isolation, and temporary occlusion of appropriately sized peripheral blood vessels. Its curved jaws provide a contoured working profile for selected peripheral vascular procedures.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 6″ DeBakey Peripheral Vascular Clamp Curved Jaws is a specialized cardiovascular and peripheral vascular surgical instrument designed to assist with controlled handling, positioning, isolation, and temporary occlusion of appropriately sized blood vessels. With an overall length of 6 inches and curved jaws , this clamp provides a practical working profile for selected peripheral vascular procedures. DeBakey peripheral vascular clamps are designed for vascular surgery where precise vessel management is required. This instrument can assist with temporary vessel occlusion, positioning, isolation, manipulation, and selected vascular repair or reconstruction procedures. The exact clinical application should always be determined by a qualified vascular or cardiovascular surgeon based on the target anatomy and operative requirements. The curved jaws provide a contoured working profile that can facilitate engagement around selected vascular structures. Curved jaws may allow the working end to approach a vessel from a suitable trajectory while helping maintain access and visibility within the operative field. Exact jaw dimensions and curvature should be verified against the manufacturer’s specifications before clinical use. At 6 inches overall length , the instrument provides useful working reach while maintaining practical maneuverability. Its moderate length can be advantageous in peripheral vascular operative fields where controlled access and precise positioning are important. The DeBakey Peripheral Vascular Clamp may be incorporated into professional vascular, cardiovascular, thoracic, and peripheral vascular surgical instrument sets . Depending on the specific working-end configuration, potential applications include temporary vascular occlusion, vessel isolation, positioning, manipulation, vascular repair, and reconstruction. Proper instrument selection is essential when working with peripheral vessels. The surgeon should consider vessel diameter, anatomical location, tissue characteristics, operative exposure, and the intended surgical technique before selecting the clamp. The working dimensions should be appropriate for the target vascular structure. Controlled application is important to help minimize potential vascular tissue trauma. The curved jaws should be accurately positioned before application, and only the force necessary for the intended clinical purpose should be used. Excessive compression, twisting, bending, or inappropriate leverage should be avoided. The curved-jaw configuration can provide a useful approach around selected peripheral vascular anatomy. This geometry may help the surgeon maintain hand clearance and visibility while positioning the clamp, depending on the operative field and surgical technique. The instrument is typically manufactured from surgical-grade stainless steel , providing mechanical strength, durability, and corrosion resistance suitable for professional reusable surgical instrumentation. Precision manufacturing supports reliable jaw alignment and consistent mechanical performance. A smooth surface finish also facilitates routine cleaning, inspection, and maintenance. After use, reusable instruments should be promptly cleaned and decontaminated according to established healthcare-facility procedures. Particular attention should be given to the curved jaws, hinge, and adjoining surfaces , where blood and biological residue may accumulate. The clamp should be inspected for corrosion, wear, deformation, surface damage, and proper jaw alignment before sterilization. Sterilization should be performed using a validated process compatible with the manufacturer’s instructions and institutional infection-control requirements. Proper handling and storage help preserve the curved jaw configuration and overall mechanical performance. The 6″ DeBakey Peripheral Vascular Clamp Curved Jaws combines a 6-inch overall length with a specialized curved-jaw design for controlled peripheral vascular handling. Its practical reach, contoured working profile, and durable construction make it a useful addition to professional vascular surgical instrument sets. Key Features DeBakey peripheral vascular clamp design 6-inch overall length Curved jaw configuration Contoured working profile Designed for selected peripheral vascular procedures Supports controlled temporary vessel occlusion Facilitates vessel positioning and manipulation Useful for vessel isolation Practical reach and maneuverability Suitable for cardiovascular and peripheral vascular surgery Surgical-grade stainless steel construction Durable design for professional reusable instrumentation Product Specifications Specification Details Product Name DeBakey Peripheral Vascular Clamp Overall Length 6″ Jaw Configuration Curved Instrument Type Peripheral Vascular Clamp Primary Function Vessel manipulation, positioning, isolation, and temporary occlusion Intended Application Appropriately sized peripheral vascular structures Surgical Specialty Vascular / Cardiovascular Surgery Typical Application Vessel control, isolation, positioning, repair, and manipulation Working Profile Curved jaws Material Surgical-grade stainless steel Reusable Yes, for reusable models Sterilization Follow validated manufacturer and facility protocols FAQs 1. What is the DeBakey Peripheral Vascular Clamp used for? It is designed to assist with controlled manipulation, positioning, isolation, and temporary occlusion of appropriately sized peripheral blood vessels during selected vascular procedures. 2. What is the overall length of this clamp? The overall length is 6 inches . 3. What do the curved jaws provide? The curved jaws provide a contoured working profile that can facilitate access and positioning around selected vascular structures. 4. Why use a curved-jaw vascular clamp? Curved jaws can provide an offset or contoured approach that may be useful when working around selected peripheral vascular anatomy. 5. Can this clamp be used for temporary vascular occlusion? Yes. It can support temporary vessel occlusion when appropriately selected for the target vessel and surgical technique. 6. Which specialties may use this instrument? It may be incorporated into selected vascular, cardiovascular, thoracic, and peripheral vascular surgical instrument sets. 7. What material is the DeBakey Peripheral Vascular Clamp made from? It is typically manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 8. How should this vascular clamp be sterilized? Reusable models should be cleaned, inspected, and sterilized using a validated process according to the manufacturer’s instructions and healthcare-facility sterilization protocols.

Instrument name6″ DeBakey Peripheral Vascular Clamp Curved Jaws
Catalogue referenceUS-58229
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image