

Catalogue reference: US-59503
The 7 1/4″ Cooley Occlusion Clamp 3.6cm Long Jaws is a precision vascular surgical instrument designed for controlled occlusion and manipulation of blood vessels. Its 7 1/4″ length and 3.6cm long jaws provide practical access and a defined working profile for selected cardiovascular and vascular procedures.
Prefer Wise or bank transfer? Choose it at checkout.
The 7 1/4″ Cooley Occlusion Clamp 3.6cm Long Jaws is a specialized cardiovascular surgical instrument designed for controlled vascular occlusion and manipulation during cardiovascular, vascular, and cardiothoracic procedures. Its Cooley-style configuration provides a practical combination of instrument length and jaw dimensions for surgical teams requiring dependable vascular control during selected operative techniques. With an overall length of 7 1/4 inches, this Cooley occlusion clamp provides a compact working profile while maintaining useful reach within the operative field. The 3.6cm long jaws provide a defined working surface for engaging appropriate vascular structures. These dimensions should be considered when selecting instrumentation for a particular procedure, vessel size, and surgical approach. Occlusion clamps are used when temporary control of blood flow through an appropriate vascular structure is required. Depending on the specific surgical technique, an occlusion clamp may assist with vessel isolation, vascular repair, reconstruction, graft-related procedures, or other applications requiring controlled vessel occlusion. The exact clinical application and duration of use should always be determined by the operating surgeon according to the patient’s anatomy and the requirements of the procedure. The 3.6cm long jaws are an important feature of this model. A defined jaw length allows the surgical team to select a clamp that corresponds appropriately with the target vessel and operative requirements. Proper sizing and positioning are essential when working with vascular structures. The instrument should be applied with appropriate surgical technique and should not be used beyond its intended clinical purpose. The Cooley occlusion clamp is designed for controlled mechanical operation. Smooth opening and closing action allows the instrument to be positioned accurately and manipulated according to the surgeon’s technique. Reliable jaw alignment is particularly important in vascular instrumentation, where precise placement and controlled handling are essential. Professional surgical clamps of this type are generally manufactured from surgical-grade stainless steel. Stainless steel is commonly selected for reusable surgical instruments because of its strength, durability, corrosion resistance, and compatibility with established cleaning and sterilization processes. Proper instrument care is essential to preserve these characteristics throughout the product’s service life. The 7 1/4″ Cooley Occlusion Clamp can be incorporated into cardiovascular surgical instrument trays, vascular surgery sets, cardiothoracic instrument collections, and specialized operating-room inventories. Its 3.6cm jaw length provides a specific configuration for facilities that require multiple vascular clamps in different sizes and working profiles. After clinical use, the clamp should be processed according to an approved surgical-instrument reprocessing procedure. Prompt cleaning helps prevent biological material from drying on the instrument. Particular attention should be given to the jaws, hinge, and other moving components. The instrument should be thoroughly rinsed and dried after cleaning before inspection. Before sterilization and subsequent use, the clamp should be inspected for correct jaw alignment, smooth mechanical movement, corrosion, surface damage, and structural integrity. Any instrument showing signs of damage or improper function should be removed from service and evaluated by qualified personnel. Sterilization should be carried out according to the manufacturer’s validated instructions and the healthcare facility’s established sterilization protocol. Proper cleaning before sterilization is essential for effective instrument processing. Following sterilization, the clamp should be stored in a suitable environment that protects it from contamination, excessive moisture, and mechanical damage. The 7 1/4″ Cooley Occlusion Clamp 3.6cm Long Jaws offers a practical combination of controlled vascular occlusion, defined jaw dimensions, and durable surgical construction. It is a useful addition to professional cardiovascular, vascular, and cardiothoracic surgical instrument collections where reliable vessel control is required. Key Features 7 1/4″ overall instrument length Cooley-style vascular occlusion clamp design 3.6cm long jaws for a defined working profile Designed for controlled vascular occlusion Suitable for selected cardiovascular surgical procedures Useful for vascular and cardiothoracic applications Supports controlled vessel handling and manipulation Practical size for specialized surgical instrument trays Durable surgical-grade stainless steel construction Corrosion-resistant material for professional reusable instrumentation Designed for controlled mechanical operation Suitable for appropriate cleaning and sterilization protocols Product Specifications Specification Details Product Name Cooley Occlusion Clamp Instrument Type Vascular Occlusion Clamp Design Cooley Style Overall Length 7 1/4 inches Jaw Length 3.6 cm Primary Function Controlled vascular occlusion Surgical Specialty Cardiovascular, Vascular, Cardiothoracic Construction Surgical-grade stainless steel Instrument Category Vascular Surgical Instrument Reusable Yes, subject to manufacturer instructions Sterilization According to validated sterilization protocols Intended Use Professional surgical applications FAQs 1. What is the 7 1/4″ Cooley Occlusion Clamp used for? The Cooley Occlusion Clamp is designed for controlled temporary occlusion and manipulation of appropriate blood vessels during selected cardiovascular, vascular, and cardiothoracic procedures. 2. What is the overall length of this Cooley Occlusion Clamp? The instrument has an overall length of 7 1/4 inches, providing a practical working reach for appropriate surgical applications. 3. How long are the jaws on this vascular clamp? The jaws are 3.6cm long, providing a defined working profile for engaging appropriate vascular structures. 4. Is this clamp suitable for cardiovascular surgery? Yes. The instrument is designed for professional cardiovascular, vascular, and cardiothoracic surgical applications where controlled vascular occlusion is required. 5. Why is jaw length important when selecting an occlusion clamp? Jaw length affects the instrument’s working profile and should be selected according to the target vessel, surgical approach, anatomy, and the surgeon’s preferred technique. 6. What material is used to manufacture the clamp? This type of reusable surgical clamp is generally manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 7. Can the Cooley Occlusion Clamp be sterilized? The instrument should be cleaned and sterilized according to the manufacturer’s validated instructions and the healthcare facility’s approved sterilization protocol.
| Instrument name | 7 1/4″ Cooley Occlusion Clamp 3.6cm Long Jaws |
|---|---|
| Catalogue reference | US-59503 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.