General Surgery Instruments

8 1/2″ Cooley Partial Occlusion Clamp 5.2cm Depth, 12mm Width

Catalogue reference: US-59498

$80.00$56.00✓ In Stock

The 8 1/2″ Cooley Partial Occlusion Clamp 5.2cm Depth, 12mm Width is a precision cardiovascular surgical instrument designed for controlled partial occlusion and manipulation of blood vessels. Its extended 5.2cm depth and 12mm width provide a practical working profile for selected vascular and cardiothoracic procedures.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 8 1/2″ Cooley Partial Occlusion Clamp 5.2cm Depth, 12mm Width is a specialized vascular surgical instrument designed for controlled partial occlusion and manipulation of blood vessels during cardiovascular, vascular, and cardiothoracic procedures. The Cooley-style configuration is intended to provide surgeons with controlled access and stable positioning when temporary partial vascular occlusion is required during operative techniques. With an overall length of 8 1/2 inches, this partial occlusion clamp provides useful reach into the operative field while maintaining a manageable profile for precise instrument handling. The 5.2cm depth and 12mm width provide a larger working configuration than narrower partial occlusion clamps, making this particular size appropriate when the surgical application requires the corresponding clamping dimensions. Selection of the appropriate clamp should always be based on vessel anatomy, surgical technique, and the clinical requirements of the procedure. Partial occlusion clamps are important instruments in cardiovascular and vascular surgery because they can provide temporary control of a portion of a blood vessel while maintaining flow through the remaining vessel lumen. This functionality can be useful during selected vascular reconstruction, vessel repair, grafting, and anastomotic procedures. The Cooley partial occlusion design is therefore a valuable addition to specialized cardiovascular surgical instrument sets. The 12mm width provides a defined working area for controlled vessel engagement, while the 5.2cm depth offers extended access to the target structure. These dimensions should be evaluated by qualified surgical professionals to ensure that the instrument is appropriate for the specific vessel size and operative technique. The clamp should be applied only according to established surgical procedures and professional clinical judgment. The instrument is designed for dependable mechanical operation, allowing controlled opening, positioning, and closure during surgery. Smooth instrument movement is particularly important in cardiovascular instrumentation, where accurate positioning and controlled handling are essential. A properly maintained vascular clamp should provide consistent mechanical performance throughout its service life. Professional surgical clamps of this type are generally manufactured from surgical-grade stainless steel. Stainless steel is widely used for reusable surgical instruments because it offers a combination of mechanical strength, durability, corrosion resistance, and suitability for repeated instrument processing. The material also supports routine handling, cleaning, disinfection, and sterilization when the instrument is processed according to validated manufacturer and healthcare-facility procedures. The 8 1/2″ Cooley Partial Occlusion Clamp can be incorporated into cardiovascular instrument trays, vascular surgery sets, cardiothoracic instrument collections, and specialized operating-room inventories. Its defined dimensions make it easier for medical facilities to select the appropriate instrument for procedures requiring a particular depth and width. Proper instrument care is essential for maintaining performance. Following use, the clamp should be cleaned promptly using an appropriate surgical-instrument cleaning process. Particular attention should be given to the jaws, hinge, and locking mechanism, where biological material or cleaning residue can accumulate. The instrument should be thoroughly rinsed, dried, inspected, and processed according to the manufacturer’s validated instructions. Before sterilization and subsequent clinical use, the instrument should be examined for correct jaw alignment, smooth operation, structural integrity, corrosion, and any signs of damage. Any instrument that does not function correctly should be removed from service and assessed by qualified personnel. Sterilization should always follow the manufacturer’s instructions and the healthcare facility’s validated sterilization protocol. Proper cleaning before sterilization is essential because residual organic material can interfere with effective sterilization. Appropriate storage should also protect the instrument from unnecessary mechanical damage, moisture, and contamination. The 8 1/2″ Cooley Partial Occlusion Clamp 5.2cm Depth, 12mm Width provides a specialized solution for surgical teams requiring a larger Cooley-style partial occlusion configuration. Its practical length, defined working dimensions, durable construction, and vascular application make it a useful component of professional cardiovascular and vascular surgical instrumentation. Key Features 8 1/2″ overall length for effective operative reach Cooley-style partial occlusion vascular clamp design 5.2cm specified working depth 12mm specified working width Designed for controlled partial vascular occlusion Suitable for cardiovascular and vascular surgical applications Useful for selected vessel repair and reconstruction procedures Supports controlled manipulation of vascular structures Durable surgical-grade stainless steel construction Designed for repeated professional instrument processing Corrosion-resistant construction for long-term service Suitable for cardiovascular and cardiothoracic surgical instrument sets Product Specifications Specification Details Product Name Cooley Partial Occlusion Clamp Instrument Type Partial Occlusion Vascular Clamp Design Cooley Style Overall Length 8 1/2 inches Working Depth 5.2 cm Working Width 12 mm Primary Function Partial vascular occlusion and vessel manipulation Surgical Specialty Cardiovascular, Vascular, Cardiothoracic Construction Surgical-grade stainless steel Instrument Category Vascular Surgical Instrument Reusable Yes, subject to manufacturer instructions Sterilization Process according to validated manufacturer and facility protocols Intended Use Professional surgical applications FAQs 1. What is the 8 1/2″ Cooley Partial Occlusion Clamp used for? The clamp is designed for controlled partial occlusion and manipulation of blood vessels during selected cardiovascular, vascular, and cardiothoracic surgical procedures. 2. What are the dimensions of this Cooley Partial Occlusion Clamp? This model has an overall length of 8 1/2 inches, a specified working depth of 5.2cm, and a specified working width of 12mm. 3. What is the purpose of a partial occlusion vascular clamp? A partial occlusion clamp is designed to temporarily control a portion of a blood vessel while allowing flow through the remaining lumen. Its use depends on the surgical technique and clinical requirements. 4. Is this Cooley clamp suitable for cardiovascular surgery? Yes. Its design is intended for professional cardiovascular, vascular, and cardiothoracic surgical applications requiring controlled partial vessel occlusion or manipulation. 5. What material is used for this surgical clamp? This type of reusable vascular clamp is generally manufactured from surgical-grade stainless steel, providing strength, durability, and corrosion resistance suitable for professional surgical instrumentation. 6. Can this vascular clamp be sterilized? The instrument should be cleaned and sterilized according to the manufacturer’s validated instructions and the healthcare facility’s approved sterilization procedures. 7. Why does the clamp have a 12mm working width? The 12mm working width defines the specified clamping profile of this model. The appropriate size should be selected according to the vessel anatomy and surgical requirements.

Instrument name8 1/2″ Cooley Partial Occlusion Clamp 5.2cm Depth, 12mm Width
Catalogue referenceUS-59498
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image