General Surgery Instruments

8 1/2″ Glover Clamp Spoon Jaw Standard

Catalogue reference: US-58752

$80.00$56.00✓ In Stock

The 8 1/2″ Glover Clamp Spoon Jaw Standard is a specialized vascular surgical instrument designed for controlled handling, positioning, isolation, and temporary occlusion of appropriately sized blood vessels. Its spoon-jaw configuration provides a broad, contoured working profile for selected vascular procedures.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 8 1/2″ Glover Clamp Spoon Jaw Standard is a specialized cardiovascular and vascular surgical instrument designed to assist with controlled manipulation, positioning, isolation, and temporary occlusion of appropriately sized vascular structures. Measuring 8 1/2 inches overall, this clamp incorporates a standard spoon-jaw configuration that provides a broad, contoured working surface for selected vascular procedures. The Glover Clamp is intended for applications where controlled vessel management and precise access are required. Its spoon-jaw profile can assist with positioning, isolating, manipulating, and temporarily occluding appropriately sized vascular structures according to the requirements of the procedure. Clinical use should always be determined by a qualified vascular or cardiovascular surgeon. The spoon jaws feature a broad, smoothly contoured working profile. This configuration can facilitate controlled engagement and positioning around selected vascular structures while providing a defined area of contact. The exact jaw dimensions, curvature, and working-end characteristics should be verified against the manufacturer’s technical specifications before clinical use. The standard configuration provides a general working profile within the Glover clamp pattern. Correct instrument selection is important because vascular anatomy varies significantly in vessel diameter, location, and surrounding structures. The clamp should therefore be selected according to the target anatomy and specific procedural requirements. At 8 1/2 inches overall length , this instrument provides extended working reach while retaining practical maneuverability. The length can be useful in cardiovascular, thoracic, and peripheral vascular operative fields where additional access distance is required. The Glover Clamp may be incorporated into professional vascular, cardiovascular, thoracic, and peripheral vascular surgical instrument sets . Potential applications include vessel positioning, isolation, manipulation, temporary occlusion, and selected vascular repair or reconstructive procedures. Proper instrument selection is essential when working with vascular tissue. Vessel diameter, anatomical location, tissue characteristics, operative exposure, and surgical technique should be considered before selecting the clamp. The spoon-jaw dimensions should be appropriate for the intended target structure. Controlled application is important to help minimize potential vascular tissue trauma. The jaws should be accurately positioned before application, and only the force necessary for the intended clinical purpose should be used. Excessive compression, twisting, bending, or inappropriate leverage should be avoided. The combination of the spoon-jaw design and 8.5-inch length provides a specialized working geometry for selected vascular applications. The broad contoured jaws can facilitate controlled vessel engagement, while the extended length provides useful access and hand clearance. The instrument is typically manufactured from surgical-grade stainless steel , providing mechanical strength, durability, and corrosion resistance suitable for professional reusable surgical instrumentation. Precision manufacturing supports reliable jaw alignment and consistent mechanical performance. A smooth surface finish also facilitates routine cleaning, inspection, and maintenance. After use, reusable instruments should be promptly cleaned and decontaminated according to established healthcare-facility procedures. Particular attention should be given to the spoon jaws, hinge, shaft, and adjoining surfaces , where blood and biological residue may accumulate. The clamp should be inspected for wear, deformation, corrosion, surface damage, and proper jaw alignment before sterilization. Sterilization should be performed using a validated process compatible with the manufacturer’s instructions and institutional infection-control requirements. Proper handling and storage help preserve the spoon-jaw geometry and mechanical performance. The 8 1/2″ Glover Clamp Spoon Jaw Standard combines an extended 8.5-inch length with a broad spoon-jaw configuration for controlled vascular handling. Its contoured working profile, useful reach, and durable construction make it a practical addition to professional vascular and cardiovascular surgical instrument sets. Key Features Glover Clamp design 8 1/2-inch overall length Standard spoon-jaw configuration Broad, contoured working surface Designed for selected vascular procedures Supports controlled temporary vascular occlusion Facilitates vessel positioning and isolation Useful for controlled vascular manipulation Provides extended working reach Practical operative-field access Surgical-grade stainless steel construction Durable professional reusable design Product Specifications Specification Details Product Name Glover Clamp Overall Length 8 1/2″ Jaw Configuration Spoon Jaw Configuration Standard Instrument Type Vascular Clamp Primary Function Vessel manipulation, positioning, isolation, and temporary occlusion Intended Application Appropriately sized vascular structures Surgical Specialty Vascular / Cardiovascular Surgery Typical Application Vessel control, positioning, isolation, and manipulation Working Profile Standard spoon jaw Material Surgical-grade stainless steel Reusable Yes, for reusable models Sterilization Follow validated manufacturer and facility protocols FAQs 1. What is the Glover Clamp used for? It is designed to assist with controlled manipulation, positioning, isolation, and temporary occlusion of appropriately sized vascular structures during selected vascular procedures. 2. What is the overall length of this clamp? The overall length is 8 1/2 inches (8.5″) . 3. What type of jaws does this model have? This model features a standard spoon-jaw configuration with a broad, contoured working surface. 4. What are spoon jaws? Spoon jaws have a broad, smoothly contoured working profile designed to facilitate controlled engagement and positioning around appropriately sized vascular structures. 5. What does “Standard” indicate? Standard identifies the general configuration of the Glover Clamp. Exact jaw dimensions should be confirmed against the applicable manufacturer specifications. 6. Can this clamp be used for temporary vascular occlusion? Yes. It can support temporary vessel occlusion when appropriately selected for the target vessel and surgical technique. 7. What material is the Glover Clamp typically made from? It is typically manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 8. How should this vascular clamp be sterilized? Reusable models should be cleaned, inspected, and sterilized using a validated process according to the manufacturer’s instructions and healthcare-facility sterilization protocols.

Instrument name8 1/2″ Glover Clamp Spoon Jaw Standard
Catalogue referenceUS-58752
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image