

Catalogue reference: US-59092
The 8 1/4″ Morris Original Ascending Aorta Clamp is a specialized cardiovascular surgical instrument designed for controlled occlusion and manipulation of the ascending aorta. Its 8 1/4-inch length provides practical reach for selected open-heart and cardiothoracic procedures requiring precise aortic control.
Prefer Wise or bank transfer? Choose it at checkout.
The 8 1/4″ Morris Original Ascending Aorta Clamp is a specialized cardiovascular surgical instrument designed for controlled occlusion and manipulation of the ascending aorta during selected cardiac and cardiothoracic procedures. Its dedicated Morris-style configuration and 8 1/4-inch overall length provide a practical combination of surgical reach and controlled instrument positioning for procedures involving major vascular structures. Ascending aorta clamps are specialized instruments used when temporary control of blood flow through the ascending aorta is required as part of a surgical technique. Depending on the procedure, an aortic clamp may be incorporated into selected open-heart, cardiovascular, aortic, or cardiothoracic operations where controlled vascular occlusion is necessary. The exact clinical application, positioning, duration of use, and vessel suitability should always be determined by the operating surgeon according to the patient’s anatomy and established surgical technique. The 8 1/4-inch overall length provides useful reach within the operative field while maintaining a manageable instrument profile. A dedicated cardiovascular clamp of this length can be useful when the target area requires additional reach compared with shorter surgical clamps. Appropriate instrument length can also support controlled handling when working within the thoracic cavity. The Morris Original Ascending Aorta Clamp is designed specifically for professional cardiovascular instrumentation. A specialized aortic clamp should provide predictable mechanical action, proper working-end alignment, and controlled closure. These characteristics are important when working around major vascular structures, where accurate instrument placement and reliable operation are essential. The product title does not provide detailed jaw dimensions, jaw angle, tooth pattern, or specific clamping pressure. These characteristics should therefore be verified from the manufacturer’s technical documentation before clinical selection. The overall length alone should not be interpreted as a recommendation for a particular vessel diameter or surgical technique. The instrument can be incorporated into cardiovascular surgical instrument sets, open-heart surgery trays, cardiothoracic collections, and specialized aortic surgery systems. It may be used alongside other cardiovascular instruments such as vascular forceps, aortic scissors, vascular needle holders, vessel dilators, graft-handling instruments, and other vascular clamps, depending on the procedure. Professional reusable vascular clamps are commonly manufactured from surgical-grade stainless steel or another suitable surgical instrument material. Stainless steel is widely used in cardiovascular instrumentation because it offers strength, durability, corrosion resistance, and compatibility with appropriate cleaning and sterilization procedures. Exact material composition, surface finish, jaw configuration, and mechanical characteristics should be confirmed with the manufacturer or supplier. Proper handling is essential for maintaining reliable cardiovascular instrument performance. Before use, the clamp should be inspected for correct jaw alignment, smooth opening and closing action, structural integrity, corrosion, surface damage, and other abnormalities. The instrument should be operated only according to established surgical technique and by appropriately trained healthcare professionals. Following use, the Morris Ascending Aorta Clamp should be cleaned promptly using a validated surgical-instrument reprocessing procedure. Particular attention should be given to the working jaws, hinge, shaft, and other mechanical components so that biological material and cleaning residues are thoroughly removed. After cleaning, the instrument should be thoroughly rinsed and dried before inspection. Any clamp showing deformation, corrosion, damaged working surfaces, or abnormal mechanical function should be removed from service and evaluated by qualified personnel. If supplied as a reusable surgical instrument, sterilization should be performed according to the manufacturer’s validated instructions and the healthcare facility’s approved sterilization protocol. Proper cleaning before sterilization is essential for effective instrument processing. After sterilization, the clamp should be stored in a clean, dry environment that protects the working end and mechanical components from impact, contamination, moisture, and unnecessary mechanical stress. The 8 1/4″ Morris Original Ascending Aorta Clamp offers a specialized solution for professional cardiovascular surgical teams requiring controlled aortic occlusion and precise instrument handling. Its dedicated ascending-aorta configuration and practical 8 1/4-inch length make it a valuable addition to specialized cardiac and cardiothoracic instrument inventories. Key Features Morris Original Ascending Aorta Clamp design 8 1/4″ overall instrument length Designed for controlled ascending aortic occlusion Suitable for selected cardiovascular and cardiothoracic procedures Useful for open-heart and aortic surgical applications Provides practical reach within the thoracic operative field Supports controlled manipulation of major vascular structures Precision-oriented mechanical configuration Durable surgical instrument construction Suitable for specialized cardiovascular instrument sets Designed for professional surgical use Suitable for appropriate cleaning and sterilization procedures Product Specifications Specification Details Product Name Morris Original Ascending Aorta Clamp Instrument Type Ascending Aorta / Vascular Clamp Overall Length 8 1/4″ Primary Function Controlled ascending aortic occlusion Surgical Specialty Cardiovascular, Cardiothoracic, Aortic Surgery Application Ascending aorta and major-vessel procedures Design Morris Original Jaw Configuration Not specified in supplied product title Jaw Length Not specified Angulation Not specified Tooth Configuration Not specified Construction Surgical-grade instrument material Reusable Subject to manufacturer specifications Sterilization According to validated sterilization protocols Intended Use Professional surgical applications FAQs 1. What is the 8 1/4″ Morris Original Ascending Aorta Clamp used for? It is designed for controlled temporary occlusion and manipulation of the ascending aorta during selected cardiovascular and cardiothoracic surgical procedures. 2. What is the overall length of the Morris Ascending Aorta Clamp? The instrument has an overall length of 8 1/4 inches , providing practical reach for appropriate surgical applications. 3. What is an ascending aorta clamp? An ascending aorta clamp is a specialized cardiovascular instrument used to provide temporary control of the ascending aorta during selected surgical procedures requiring controlled vascular occlusion. 4. Is this Morris clamp suitable for cardiac surgery? Yes. It is designed for specialized cardiovascular and cardiothoracic applications involving controlled manipulation or occlusion of the ascending aorta. 5. Why is the clamp 8 1/4 inches long? The length provides useful surgical reach while maintaining a manageable profile for operative access within the thoracic field. 6. Does the product title specify the jaw dimensions? No. The supplied title provides the overall length and instrument designation but does not specify jaw length, jaw angle, tooth configuration, or clamping pressure. These details should be confirmed with the manufacturer. 7. What material is commonly used for this type of aortic clamp? Reusable cardiovascular clamps are commonly manufactured from surgical-grade stainless steel or another suitable surgical instrument material. Exact material specifications should be confirmed with the manufacturer.
| Instrument name | 8 1/4″ Morris Original Ascending Aorta Clamp |
|---|---|
| Catalogue reference | US-59092 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.