General Surgery Instruments

8 1/4″ Wylie External Carotid Clamp

Catalogue reference: US-59014

$80.00$56.00✓ In Stock

The 8 1/4″ Wylie External Carotid Clamp is a specialized vascular surgical instrument designed for controlled handling of appropriately sized external carotid vascular structures. Its extended length provides useful reach and maneuverability for selected carotid and vascular procedures.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 8 1/4″ Wylie External Carotid Clamp is a specialized cardiovascular and vascular surgical instrument designed to assist with controlled manipulation, positioning, isolation, and temporary occlusion of appropriately sized vascular structures associated with the external carotid circulation. Measuring 8 1/4 inches overall, this clamp provides extended working reach for selected carotid and vascular procedures. The Wylie External Carotid Clamp is intended for procedures where controlled management of carotid vessels is required. It may assist with vessel positioning, isolation, manipulation, and temporary occlusion according to the operative requirements. Clinical application should always be determined by a qualified vascular or cardiovascular surgeon based on patient anatomy and surgical technique. The specialized working configuration is designed to facilitate access to the external carotid region while maintaining practical instrument control. Its geometry can provide useful positioning around vascular structures and surrounding anatomical tissues where a general-purpose straight clamp may not provide the preferred approach. At 8 1/4 inches overall length , the instrument provides extended working distance while maintaining maneuverability. This can be advantageous in vascular operative fields where the target vessel requires controlled access and the surgeon benefits from additional clearance between the hand and operative site. The Wylie External Carotid Clamp may be incorporated into professional vascular, cardiovascular, carotid, and head-and-neck vascular surgical instrument sets . Potential applications include carotid vessel positioning, isolation, controlled manipulation, temporary occlusion, and assistance during selected vascular reconstructive procedures. Proper instrument selection is essential when working with carotid anatomy. Vessel diameter, anatomical location, tissue characteristics, operative exposure, and procedural requirements should be evaluated before selecting the clamp. Exact jaw dimensions and working-end characteristics should be verified against the manufacturer’s technical documentation. Controlled application is particularly important around carotid vessels. The working end should be accurately positioned before application, and only the force necessary for the intended clinical purpose should be used. Excessive compression, twisting, bending, or inappropriate leverage should be avoided to help minimize potential vascular tissue trauma. The extended length provides useful access while maintaining practical hand positioning. This can be helpful in selected carotid procedures where controlled vessel management and clear operative access are required. The instrument is typically manufactured from surgical-grade stainless steel , providing strength, durability, and corrosion resistance suitable for professional reusable surgical instrumentation. Precision manufacturing supports reliable working-end alignment and consistent mechanical performance. A smooth finish also facilitates routine cleaning, inspection, and maintenance. After use, reusable instruments should be promptly cleaned and decontaminated according to established healthcare-facility procedures. Particular attention should be given to the working jaws, hinge, shaft, and adjoining surfaces , where blood and biological residue may accumulate. The clamp should be inspected for wear, deformation, corrosion, surface damage, and proper jaw alignment before sterilization. Sterilization should be performed using a validated process compatible with the manufacturer’s instructions and institutional infection-control requirements. Proper handling and storage help preserve the working-end geometry and mechanical performance. The 8 1/4″ Wylie External Carotid Clamp combines an extended 8.25-inch length with a specialized carotid working profile for controlled vascular handling. Its useful reach, practical maneuverability, and durable construction make it a valuable addition to professional carotid and vascular surgical instrument sets. Key Features Wylie External Carotid Clamp design 8 1/4-inch overall length Specialized carotid vascular profile Designed for selected external carotid procedures Provides extended working reach Supports controlled vessel positioning Facilitates vascular isolation and manipulation Supports temporary vascular occlusion Practical operative-field maneuverability Suitable for selected carotid vascular procedures Surgical-grade stainless steel construction Durable professional reusable design Product Specifications Specification Details Product Name Wylie External Carotid Clamp Overall Length 8 1/4″ Instrument Type External Carotid / Vascular Clamp Primary Function Vessel manipulation, positioning, isolation, and temporary occlusion Intended Application Appropriately sized carotid vascular structures Anatomical Application External carotid region Surgical Specialty Vascular / Cardiovascular Surgery Typical Application Carotid vessel control, positioning, isolation, and manipulation Working Reach Extended Material Surgical-grade stainless steel Reusable Yes, for reusable models Sterilization Follow validated manufacturer and facility protocols FAQs 1. What is the Wylie External Carotid Clamp used for? It is designed to assist with controlled manipulation, positioning, isolation, and temporary occlusion of appropriately sized vascular structures associated with the external carotid circulation. 2. What is the overall length of this clamp? The overall length is 8 1/4 inches (8.25″) . 3. What is the external carotid artery? The external carotid artery is a major branch of the common carotid artery that supplies blood to structures of the head and neck. 4. Why is an extended-length clamp useful in carotid surgery? The 8.25-inch length provides additional working reach and can facilitate controlled access while maintaining practical hand clearance from the operative field. 5. Can this clamp be used for temporary vascular occlusion? Yes. It can support temporary vessel occlusion when appropriately selected for the target anatomy and surgical technique. 6. Which specialties may use this instrument? It may be incorporated into vascular, cardiovascular, carotid, and head-and-neck vascular surgical instrument sets. 7. What material is the Wylie External Carotid Clamp typically made from? It is typically manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 8. How should this carotid clamp be sterilized? Reusable models should be cleaned, inspected, and sterilized using a validated process according to the manufacturer’s instructions and healthcare-facility sterilization protocols.

Instrument name8 1/4″ Wylie External Carotid Clamp
Catalogue referenceUS-59014
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image