General Surgery Instruments

8″ Vena Cava Clamp Non Crushing Jaw

Catalogue reference: US-59494

$80.00$56.00✓ In Stock

The 8″ Vena Cava Clamp Non-Crushing Jaw is a specialized vascular surgical instrument designed for controlled clamping of suitable vena cava structures. Its non-crushing jaw configuration supports careful vascular handling where atraumatic tissue contact is required.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 8″ Vena Cava Clamp Non Crushing Jaw is a specialized cardiovascular vascular clamp designed for controlled temporary occlusion and manipulation of suitable vena cava structures during appropriate cardiovascular and vascular surgical procedures. Its 8-inch overall length and non-crushing jaw configuration provide a specialized combination of surgical reach and controlled contact for delicate vascular handling. Vena cava clamps are specialized instruments used by trained cardiovascular and vascular surgical professionals when temporary control of an appropriate portion of the vena cava is required. The clamp may be positioned on a suitable vascular structure to establish localized occlusion while the intended surgical intervention is performed. Exact vessel selection, clamp placement, applied force, and duration should always be determined by the operating surgeon according to patient anatomy and established surgical technique. The non-crushing jaw design is an important feature of this model. It is intended to support controlled contact with suitable vascular structures while reducing unnecessary compression compared with conventional crushing configurations. The term “non-crushing” describes the intended jaw characteristic; appropriate surgical technique and controlled application remain essential to protect delicate vascular tissue. The 8-inch overall length provides practical reach for appropriate cardiovascular surgical applications. This length can allow the working end to reach suitable vascular structures while maintaining accessible hand positioning. The ideal instrument length depends on the operative approach, anatomical depth, and specific procedure. The Vena Cava Clamp can be incorporated into cardiovascular surgical instrument sets, cardiac surgery trays, thoracic vascular instrument collections, major vascular surgery sets, and vena cava procedure systems . It can complement vascular forceps, vascular scissors, vessel dilators, vascular needle holders, retractors, bulldog clamps, and other specialized cardiovascular instruments. Controlled application is particularly important when working with major vascular structures. Excessive pressure, incorrect positioning, or prolonged clamping can potentially result in vascular or surrounding tissue injury. The clamp should therefore only be applied to suitable anatomy by trained surgical professionals following established clinical technique. The non-crushing configuration can be especially relevant when controlled vascular contact is required. Surgical teams should select the clamp based on the target vessel, procedure, required degree of occlusion, anatomical access, and surgeon preference. Before every procedure, the Vena Cava Clamp should be carefully inspected for correct jaw alignment, smooth mechanical operation, structural integrity, and condition of the working surfaces. The non-crushing jaws should remain properly aligned and free from deformation, excessive wear, corrosion, or visible damage. For reusable configurations, the instrument should be cleaned and decontaminated promptly after use according to validated healthcare-facility instrument-processing procedures. Particular attention should be given to the non-crushing jaw surfaces, hinge, and other mechanical areas where biological material may accumulate. After cleaning, the clamp should be inspected again for proper mechanical function and structural condition. Sterilization should be performed using a validated process compatible with the instrument and consistent with applicable manufacturer instructions and institutional protocols. Proper cleaning, sterilization, handling, and storage help maintain instrument integrity and service life. For hospitals, cardiovascular surgeons, vascular surgeons, cardiothoracic surgical teams, operating rooms, surgical centers, and medical instrument suppliers, the 8″ Vena Cava Clamp Non-Crushing Jaw provides a specialized option for controlled vascular occlusion and careful handling of suitable vena cava structures. Its 8-inch length and non-crushing jaw configuration make it a practical addition to professional cardiovascular and major vascular surgical instrument collections. Key Features Vena Cava Clamp design 8″ overall length Non-crushing jaw configuration Designed for controlled vascular occlusion Suitable for appropriate vena cava applications Supports careful handling of suitable vascular structures Practical length for cardiovascular surgical access Designed for controlled jaw contact Suitable for cardiovascular and vascular instrument sets Useful for major vascular surgical procedures Designed for professional surgical handling Requires proper cleaning, inspection, sterilization, and storage Product Specifications Specification Details Product Name Vena Cava Clamp Instrument Type Vascular Occlusion Clamp Overall Length 8″ Jaw Type Non-Crushing Primary Application Cardiovascular Surgery Secondary Applications Vascular & Cardiothoracic Surgery Intended Use Controlled Vascular Clamping Target Anatomy Vena Cava Jaw Configuration Non-Crushing Operation Manual Construction Surgical Instrument Sterilization According to validated facility protocol and manufacturer guidance Intended Users Trained Surgical Professionals Clinical Environment Hospitals, Operating Rooms & Surgical Centers FAQs 1. What is an 8″ Vena Cava Clamp used for? The 8″ Vena Cava Clamp is designed for controlled temporary clamping and manipulation of suitable vena cava structures during selected cardiovascular and vascular procedures. 2. What does non-crushing jaw mean? A non-crushing jaw refers to a jaw configuration designed for controlled vascular contact while minimizing unnecessary crushing forces when properly applied. 3. What is the length of this Vena Cava Clamp? This model has a specified 8-inch overall length , providing practical reach for appropriate cardiovascular surgical applications. 4. Is this Vena Cava Clamp suitable for cardiovascular surgery? It is designed for appropriate cardiovascular and major vascular applications involving suitable vena cava structures, subject to professional surgical judgment. 5. Why is a non-crushing clamp useful in vascular surgery? A non-crushing configuration is intended to provide controlled contact with suitable vascular structures where careful tissue handling is important. 6. How should the Vena Cava Clamp be sterilized? For reusable configurations, it should be thoroughly cleaned, decontaminated, inspected, and sterilized using a validated process consistent with manufacturer guidance and healthcare-facility protocols. 7. How should this vascular clamp be maintained? The non-crushing jaws, hinge, alignment, and overall structure should be inspected after cleaning and before reuse for proper mechanical function, deformation, wear, or visible damage.

Instrument name8″ Vena Cava Clamp Non Crushing Jaw
Catalogue referenceUS-59494
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image