General Surgery Instruments

9 1/2″ Wylie Hypogastric Clamp

Catalogue reference: US-58686

$80.00$56.00✓ In Stock

The 9 1/2″ Wylie Hypogastric Clamp is a specialized vascular surgical instrument designed for controlled clamping and manipulation of hypogastric vessels. Its extended 9 1/2-inch length provides useful reach and maneuverability for selected pelvic, vascular, and reconstructive procedures.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 9 1/2″ Wylie Hypogastric Clamp is a specialized vascular surgical instrument designed for controlled clamping, temporary occlusion, and manipulation of the hypogastric vessels during appropriately indicated vascular and pelvic procedures. Its Wylie-style configuration and extended 9 1/2-inch overall length provide a practical combination of reach and controlled handling for procedures involving deeper vascular anatomy. The hypogastric arteries, commonly referred to as the internal iliac arteries , are major pelvic vessels that supply blood to structures within the pelvis and gluteal region. Surgical procedures involving these vessels may require specialized vascular clamps that provide appropriate access and controlled temporary occlusion. The Wylie Hypogastric Clamp is designed for this type of specialized vascular instrumentation, with its use determined by the operating surgeon according to the patient’s anatomy and procedural requirements. The 9 1/2-inch length provides extended working reach, which can be particularly useful when the target vascular structures are located deep within the pelvic or abdominal operative field. The longer shaft allows the surgeon to maintain a controlled hand position while directing the working end toward the intended vessel. This can help improve access while maintaining practical instrument maneuverability. Wylie-style vascular clamps are intended to provide controlled mechanical handling during vascular procedures. Proper jaw alignment and smooth opening and closing are important for accurate positioning and reliable release. The instrument should be used carefully and only for its intended surgical purpose. A specialized hypogastric clamp may be incorporated into vascular surgery, pelvic vascular reconstruction, abdominal surgery, and selected gynecologic or urologic procedures where control of the internal iliac or related vascular structures is required. Potential applications can include temporary vessel occlusion, vascular exposure, manipulation, or positioning. The exact indication depends on the operative technique and surgeon’s assessment. The extended design can provide useful clearance around surrounding tissues and other instruments. This may be beneficial in complex pelvic or abdominal surgical fields where direct access to a vessel is restricted by surrounding anatomy. The dedicated configuration of the Wylie Hypogastric Clamp makes it a useful component of specialized vascular instrument trays. Professional reusable vascular clamps are commonly manufactured from surgical-grade stainless steel , selected for mechanical strength, durability, and corrosion resistance. Precision manufacturing helps preserve the instrument’s working geometry and mechanical function through repeated clinical use. Proper care is essential to prevent deformation or damage to the working end. After each procedure, the 9 1/2″ Wylie Hypogastric Clamp should be cleaned promptly according to the manufacturer’s validated instructions and the healthcare facility’s approved instrument-reprocessing protocol. Blood and tissue residue should be removed thoroughly from the jaws, hinge, and other accessible surfaces. The instrument should then be rinsed, dried, inspected, and sterilized using a validated process compatible with the instrument. Before reuse, trained personnel should inspect the clamp for jaw alignment, smooth mechanical movement, corrosion, surface damage, and structural integrity . Any instrument showing deformation, excessive wear, or impaired function should be removed from service and evaluated according to institutional procedures. The 9 1/2″ Wylie Hypogastric Clamp provides specialized reach and controlled vascular handling for appropriately selected procedures involving the hypogastric vessels. It is a practical addition to professional Wylie vascular clamps, hypogastric artery clamps, pelvic vascular surgical instruments, and vascular surgery instrument sets . Key Features 9 1/2-inch overall length provides extended surgical reach. Wylie-style configuration designed for specialized vascular applications. Intended for controlled manipulation of hypogastric vessels. Supports temporary vascular occlusion when clinically indicated. Useful for selected pelvic and abdominal vascular procedures. Extended shaft provides practical clearance within deep operative fields. Facilitates controlled positioning around pelvic vascular structures. Suitable for vascular and reconstructive surgical instrument sets. Surgical-grade stainless steel construction supports durability. Designed for controlled mechanical operation and precise handling. Requires inspection for jaw alignment and structural integrity before use. Reprocessing should follow validated manufacturer and facility protocols. Product Specifications Specification Details Product Name Wylie Hypogastric Clamp Instrument Type Vascular / Artery Clamp Overall Length 9 1/2 inches Design Wylie Type Primary Application Hypogastric vessel clamping Primary Function Vascular occlusion and manipulation Anatomical Target Hypogastric / Internal Iliac Vessels Applications Vascular, pelvic, abdominal surgery Working Reach Extended Material Surgical-grade stainless steel Reusable Yes, when supplied as a reusable instrument Sterilization Follow manufacturer-validated instructions Intended Users Trained surgical professionals FAQs 1. What is the 9 1/2″ Wylie Hypogastric Clamp used for? It is designed for controlled clamping, temporary occlusion, manipulation, and positioning of hypogastric vessels during appropriate vascular and pelvic surgical procedures. 2. What are hypogastric vessels? The term hypogastric arteries commonly refers to the internal iliac arteries, which are major vessels supplying structures within the pelvis and surrounding regions. 3. How long is this Wylie Hypogastric Clamp? The overall length is 9 1/2 inches , providing extended reach for deeper pelvic and abdominal operative fields. 4. Why is an extended-length hypogastric clamp useful? The longer length can provide additional reach and help maintain practical hand positioning when accessing vascular structures located deep within the pelvic or abdominal surgical field. 5. Is this clamp suitable for vascular surgery? Yes. It is specialized vascular instrumentation intended for appropriate procedures involving the hypogastric or internal iliac vessels, based on surgeon selection and operative requirements. 6. What material is the Wylie Hypogastric Clamp made from? Professional reusable vascular clamps of this type are commonly manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 7. How should the Wylie Hypogastric Clamp be sterilized? When supplied as a reusable instrument, it should be cleaned, inspected, and sterilized according to the manufacturer’s validated instructions and the healthcare facility’s approved instrument-processing protocol.

Instrument name9 1/2″ Wylie Hypogastric Clamp
Catalogue referenceUS-58686
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image