General Surgery Instruments

9 1/4″ Crafoord Coarctation Vascular Clamp

Catalogue reference: US-59098

$80.00$56.00✓ In Stock

The 9 1/4″ Crafoord Coarctation Vascular Clamp is a specialized cardiovascular surgical instrument designed for controlled occlusion and manipulation of major vascular structures. Its extended 9 1/4-inch length provides useful reach for selected cardiovascular and aortic procedures requiring precise vascular control.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 9 1/4″ Crafoord Coarctation Vascular Clamp is a specialized vascular surgical instrument designed for controlled occlusion and manipulation of major blood vessels during cardiovascular and thoracic surgical procedures. The Crafoord coarctation clamp configuration is associated with vascular procedures requiring accurate control of major vessels, particularly in operations involving the aorta and related vascular structures. With an overall length of 9 1/4 inches, this vascular clamp provides extended surgical reach for operative fields where the target vessel may be located deeper within the thoracic cavity. The longer profile can allow the surgeon to position the working end while maintaining the handle at a practical distance from the immediate surgical site, supporting controlled instrument handling during complex cardiovascular procedures. Crafoord-style coarctation clamps are designed for specialized vascular applications in which temporary control of blood flow is required. They may be incorporated into procedures involving aortic coarctation repair and other selected operations requiring controlled manipulation or occlusion of appropriate major vascular structures. The specific clinical indication, vessel selection, positioning, and duration of occlusion must always be determined by the operating surgeon based on patient anatomy and the operative technique. The coarctation clamp design is intended to provide controlled engagement of the target vessel while supporting access within the surgical field. Proper jaw alignment and reliable mechanical operation are important characteristics of cardiovascular instrumentation. The clamp should open and close smoothly and maintain appropriate alignment throughout use, allowing the surgical team to position it according to established surgical technique. The 9 1/4-inch length is an important feature for surgical access. Extended vascular clamps are often selected when working around structures that are difficult to reach with shorter instruments. In thoracic and cardiovascular surgery, appropriate instrument length can support positioning while reducing the need for excessive hand movement within the operative field. Because the product title does not specify detailed jaw dimensions, angulation, tooth configuration, or a particular vessel diameter range, those characteristics should be verified against the manufacturer’s technical specifications before clinical selection. The overall length alone should not be interpreted as a recommendation for a specific vessel size or procedure. The Crafoord Coarctation Vascular Clamp can be incorporated into cardiovascular surgery sets, thoracic instrument trays, aortic surgery collections, and specialized vascular instrument systems. It can complement other cardiovascular instruments such as vascular forceps, vascular scissors, aortic clamps, vessel dilators, needle holders, and graft-handling instruments. Professional vascular clamps are commonly manufactured from surgical-grade stainless steel or another suitable surgical instrument material. Stainless steel is widely used because it offers strength, durability, corrosion resistance, and compatibility with appropriate cleaning and sterilization procedures. Exact material composition, surface finish, jaw configuration, and mechanical specifications should be confirmed with the manufacturer or supplier. Careful instrument handling is essential when using a specialized vascular clamp. Before use, the instrument should be inspected for proper jaw alignment, smooth movement, structural integrity, corrosion, surface damage, and any signs of deformation. The clamp should be used only by qualified healthcare professionals according to established cardiovascular surgical procedures. After use, the clamp should be cleaned promptly according to the manufacturer’s validated instrument-processing instructions. Particular attention should be given to the working jaws, hinge, and mechanical components to ensure that biological material and cleaning residues are removed. The instrument should be thoroughly rinsed and dried before inspection. Any clamp showing damaged working surfaces, deformation, corrosion, or abnormal mechanical operation should be removed from clinical service and evaluated by qualified personnel. Regular inspection helps maintain reliable performance and supports appropriate surgical instrument management. If supplied as a reusable surgical instrument, sterilization should be performed according to the manufacturer’s validated instructions and the healthcare facility’s approved sterilization protocol. Proper cleaning before sterilization is essential for effective processing. Following sterilization, the clamp should be stored in a clean, dry environment that protects the instrument from impact, contamination, moisture, and unnecessary mechanical stress. The 9 1/4″ Crafoord Coarctation Vascular Clamp provides extended surgical reach and specialized vascular control for professional cardiovascular and thoracic procedures. Its dedicated coarctation-clamp configuration makes it a valuable addition to surgical facilities requiring dependable instrumentation for major-vessel occlusion and manipulation. Key Features Crafoord-style coarctation vascular clamp 9 1/4″ overall length Designed for controlled vascular occlusion Suitable for selected cardiovascular and thoracic procedures Associated with specialized aortic and coarctation surgery Extended length for deeper operative access Supports controlled manipulation of major vascular structures Precision-oriented mechanical configuration Durable surgical instrument construction Suitable for cardiovascular and vascular instrument sets Designed for professional surgical use Suitable for appropriate cleaning and sterilization procedures Product Specifications Specification Details Product Name Crafoord Coarctation Vascular Clamp Instrument Type Vascular / Coarctation Clamp Overall Length 9 1/4″ Primary Function Controlled vascular occlusion and vessel manipulation Surgical Specialty Cardiovascular, Vascular, Thoracic Surgery Application Major-vessel and aortic surgical procedures Design Crafoord Coarctation Jaw Configuration Not specified in supplied product title Jaw Length Not specified Angulation Not specified Tooth Configuration Not specified Construction Surgical-grade instrument material Reusable Subject to manufacturer specifications Sterilization According to validated sterilization protocols Intended Use Professional surgical applications FAQs 1. What is the 9 1/4″ Crafoord Coarctation Vascular Clamp used for? It is designed for controlled occlusion and manipulation of appropriate major vascular structures during selected cardiovascular, thoracic, and aortic procedures. 2. What is the overall length of this Crafoord clamp? The instrument has an overall length of 9 1/4 inches , providing extended reach for appropriate operative applications. 3. What is a Crafoord coarctation clamp? A Crafoord coarctation clamp is a specialized vascular instrument associated with procedures requiring controlled manipulation or temporary occlusion of major vessels, particularly in selected aortic and coarctation procedures. 4. Is this clamp suitable for cardiovascular surgery? Yes. It is designed as a specialized cardiovascular and vascular instrument for procedures requiring controlled major-vessel occlusion and manipulation. 5. Why is the clamp 9 1/4 inches long? The extended length provides additional reach into deeper operative fields, which can be useful during selected thoracic and cardiovascular procedures. 6. Does the product title specify the jaw dimensions? No. The supplied title provides the overall length and instrument type but does not specify jaw length, angulation, tooth configuration, or vessel diameter. These details should be confirmed with the manufacturer. 7. What material is typically used for a vascular clamp? Professional reusable vascular clamps are commonly manufactured from surgical-grade stainless steel or another suitable surgical instrument material. Exact specifications should be confirmed with the manufacturer or supplier

Instrument name9 1/4″ Crafoord Coarctation Vascular Clamp
Catalogue referenceUS-59098
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image