General Surgery Instruments

9 5/8″ Cleveland Clinic Renal Clamp Right Large

Catalogue reference: US-57452

$80.00$56.00✓ In Stock

The 9 5/8″ Cleveland Clinic Renal Clamp Right Large is a specialized vascular instrument designed for controlled clamping and manipulation of the right renal vessels. Its extended length and right-sided large configuration provide useful reach and positioning for selected renal and vascular procedures.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 9 5/8″ Cleveland Clinic Renal Clamp Right Large is a specialized renal vascular surgical instrument designed for controlled clamping, temporary occlusion, and manipulation of renal blood vessels during appropriately indicated surgical procedures. Its 9 5/8-inch overall length , right-sided configuration, and large pattern provide specialized access and working orientation for procedures involving the right renal vascular anatomy. Renal vascular clamps are used when temporary control of renal blood vessels is required during selected surgical procedures. Controlled occlusion can help provide a stable operative field during procedures involving renal vessel exposure, repair, reconstruction, or other interventions. The specific use of the clamp should always be determined by the operating surgeon based on patient anatomy, procedural requirements, and surgical technique. The right configuration is a defining characteristic of this instrument. A right-sided renal clamp is intended to facilitate access and positioning toward the right renal vascular structures. This specialized orientation can be beneficial compared with a general-purpose vascular clamp when the surgical approach requires a dedicated right-sided instrument. The large pattern identifies the particular configuration of the clamp and should be matched appropriately to the anatomy and requirements of the procedure. Proper instrument selection is important because renal vascular structures vary in size and location. The working end should be selected according to the surgeon’s preferred technique and the intended clinical application. At 9 5/8 inches , this Cleveland Clinic renal clamp provides extended reach for deeper abdominal or retroperitoneal operative fields. The longer shaft allows the surgeon to maintain practical hand positioning while directing the working end toward the target renal vessel. It may also provide useful clearance around adjacent anatomy, retractors, grafts, and other surgical instruments. The specialized design makes the clamp suitable for professional renal, urologic, vascular, abdominal, and cardiovascular surgical instrument sets , depending on the procedure. It can support temporary vessel occlusion, manipulation, positioning, and controlled exposure when clinically appropriate. Smooth mechanical action and proper jaw alignment are essential for reliable vascular instrumentation. The clamp should open and close smoothly and should be positioned carefully around the intended vessel. It should not be forcibly bent, twisted, or used outside its intended surgical purpose. Professional reusable renal and vascular clamps are commonly manufactured from surgical-grade stainless steel , selected for mechanical strength, durability, and corrosion resistance when properly maintained. Precision construction helps preserve the intended jaw configuration and mechanical performance through repeated clinical use. After use, the 9 5/8″ Cleveland Clinic Renal Clamp Right Large should be cleaned promptly according to the manufacturer’s validated instructions and the healthcare facility’s approved instrument-reprocessing protocol. Blood and tissue residue should be thoroughly removed from the working surfaces, hinge, and other accessible areas. The instrument should then be rinsed, dried, inspected, and sterilized using a validated process compatible with the instrument. Before reuse, trained personnel should inspect the clamp for jaw alignment, smooth opening and closing, corrosion, surface damage, and structural integrity . Particular attention should be given to the right-sided working configuration and jaw alignment. Any instrument showing deformation, excessive wear, or impaired function should be removed from service and evaluated according to institutional procedures. The 9 5/8″ Cleveland Clinic Renal Clamp Right Large combines extended surgical reach with a specialized right-sided configuration for controlled renal vascular handling. It is a practical addition to professional renal clamps, Cleveland Clinic-pattern vascular instruments, right renal artery clamps, urologic surgical instruments, and vascular surgery instrument sets . Key Features 9 5/8-inch overall length provides extended surgical reach. Right-sided configuration supports specialized right renal access. Large pattern identifies the specified renal clamp configuration. Designed for controlled renal vessel clamping and manipulation. Supports temporary vascular occlusion when clinically indicated. Extended shaft provides useful access to deeper operative fields. Facilitates controlled positioning around right renal vascular structures. Suitable for selected renal, urologic, vascular, and abdominal procedures. Surgical-grade stainless steel construction supports durability. Designed for controlled mechanical movement and precise handling. Requires inspection for jaw alignment and structural integrity before use. Reprocessing should follow validated manufacturer and facility protocols. Product Specifications Specification Details Product Name Cleveland Clinic Renal Clamp Instrument Type Renal / Vascular Clamp Overall Length 9 5/8 inches Configuration Right Pattern Large Primary Application Right renal vessel clamping Primary Function Vascular occlusion and manipulation Applications Renal, urologic, vascular, abdominal surgery Working Reach Extended Material Surgical-grade stainless steel Reusable Yes, when supplied as a reusable instrument Sterilization Follow manufacturer-validated instructions Intended Users Trained surgical professionals FAQs 1. What is the 9 5/8″ Cleveland Clinic Renal Clamp used for? It is designed for controlled clamping, temporary occlusion, manipulation, and positioning of renal vessels during appropriately selected renal and vascular procedures. 2. What does the right configuration mean? The right configuration indicates a specialized working orientation intended to facilitate access to the right renal vascular anatomy. 3. What does the large pattern indicate? The large pattern identifies the specified size configuration of the renal clamp and should be matched to the anatomy and surgical requirements. 4. How long is this Cleveland Clinic Renal Clamp? The overall length is 9 5/8 inches , providing extended reach for deeper abdominal and retroperitoneal operative fields. 5. Can this renal clamp be used in urologic procedures? It may be appropriate for selected renal and urologic procedures requiring controlled renal vessel manipulation or temporary occlusion, according to surgeon preference and operative technique. 6. What material is the Cleveland Clinic Renal Clamp made from? Professional reusable vascular clamps of this type are commonly manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 7. How should the renal clamp be sterilized? When supplied as a reusable instrument, it should be cleaned, inspected, and sterilized according to the manufacturer’s validated instructions and the healthcare facility’s approved instrument-processing protocol.

Instrument name9 5/8″ Cleveland Clinic Renal Clamp Right Large
Catalogue referenceUS-57452
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image