General Surgery Instruments

9 5/8″ DeBakey Acutely Curved Clamp

Catalogue reference: US-58233

$80.00$56.00✓ In Stock

The 9 5/8″ DeBakey Acutely Curved Clamp is a specialized vascular surgical instrument designed for controlled clamping and manipulation of blood vessels. Its extended length and acutely curved profile provide useful reach and angled access in selected cardiovascular and vascular procedures.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 9 5/8″ DeBakey Acutely Curved Clamp is a specialized vascular surgical instrument designed for controlled clamping, temporary occlusion, manipulation, and positioning of blood vessels during appropriately indicated cardiovascular and vascular procedures. Its 9 5/8-inch overall length and acutely curved configuration provide a specialized combination of extended reach and angled access for challenging operative fields. The defining characteristic of this DeBakey clamp is its acutely curved working configuration . The pronounced curvature allows the working end to approach vascular structures from an angled direction rather than requiring a straight-line approach. This can be particularly useful when surrounding anatomical structures, grafts, retractors, or other instruments make direct access difficult. The curved profile can help the surgeon position the working end while keeping the handles in a practical orientation. At 9 5/8 inches in overall length , the instrument provides extended surgical reach. This can be valuable when the target vessel is positioned deeper within the operative field. The elongated shaft allows the surgeon to maintain controlled hand positioning away from the immediate surgical site while directing the curved working end toward the intended vascular structure. DeBakey-style vascular instruments are designed for controlled handling of blood vessels. A specialized acutely curved clamp may be used for temporary vascular occlusion, vessel manipulation, positioning, or controlled exposure , depending on its exact working-end configuration and the requirements of the procedure. The appropriate clinical application should always be determined by the operating surgeon based on patient anatomy, surgical technique, and institutional protocols. The curved geometry can provide useful clearance around adjacent anatomical structures. This is particularly relevant in cardiovascular and vascular procedures where access may be restricted and multiple surgical instruments must be coordinated within a limited operative field. The specialized configuration can make the instrument a valuable component of professional vascular, cardiovascular, and thoracic surgical instrument sets . Controlled mechanical operation is essential for reliable instrument performance. The clamp should open and close smoothly, with the working end remaining properly aligned throughout its range of motion. It should not be forcibly twisted, bent, or used as a general-purpose tissue-grasping instrument outside its intended application. Professional reusable vascular clamps are commonly manufactured from surgical-grade stainless steel , selected for mechanical strength, durability, and corrosion resistance when properly maintained. Precision manufacturing helps preserve the intended curved geometry and mechanical function. Proper care and handling are important for maintaining the working configuration through repeated clinical use. After use, the 9 5/8″ DeBakey Acutely Curved Clamp should be cleaned promptly according to the manufacturer’s validated instructions and the healthcare facility’s approved instrument-reprocessing protocol. Blood and tissue residue should be thoroughly removed from the working end, hinge, and other accessible areas. The instrument should then be rinsed, dried, inspected, and sterilized using a validated process compatible with the instrument. Before reuse, trained personnel should inspect the clamp for jaw alignment, smooth mechanical movement, corrosion, surface damage, and deformation of the curved working end . Any instrument exhibiting impaired movement, structural damage, or abnormal alignment should be removed from service and evaluated according to institutional procedures. The 9 5/8″ DeBakey Acutely Curved Clamp combines extended reach with a specialized curved configuration for controlled vascular handling. It is a practical addition to professional DeBakey vascular clamps, acutely curved surgical clamps, cardiovascular instruments, vascular surgery clamps, and thoracic surgical instrument sets . Key Features 9 5/8-inch overall length provides extended surgical reach. Acutely curved configuration facilitates angled vascular access. DeBakey-style design for specialized vascular applications. Designed for controlled clamping and manipulation of blood vessels. Supports temporary vascular occlusion when clinically indicated. Curved profile can improve positioning around adjacent anatomy. Extended shaft provides useful clearance from the operative site. Suitable for selected cardiovascular and vascular procedures. Surgical-grade stainless steel construction supports durability. Designed for controlled mechanical movement and precise handling. Requires inspection for curved-end deformation and jaw alignment. Reprocessing should follow validated manufacturer and facility protocols. Product Specifications Specification Details Product Name DeBakey Acutely Curved Clamp Instrument Type Vascular / Surgical Clamp Overall Length 9 5/8 inches Working Configuration Acutely Curved Design DeBakey Type Primary Function Vascular clamping and manipulation Applications Cardiovascular, vascular, thoracic surgery Working Reach Extended Material Surgical-grade stainless steel Reusable Yes, when supplied as a reusable instrument Sterilization Follow manufacturer-validated instructions Intended Users Trained surgical professionals FAQs 1. What is the 9 5/8″ DeBakey Acutely Curved Clamp used for? It is designed for controlled clamping, temporary vascular occlusion, manipulation, and positioning of blood vessels during appropriately selected vascular and cardiovascular procedures. 2. What does acutely curved mean on a surgical clamp? An acutely curved configuration means the working end has a pronounced curve, allowing the clamp to approach vascular structures from a specialized angle. 3. How long is the DeBakey Acutely Curved Clamp? The overall length is 9 5/8 inches , providing extended reach for deeper or restricted operative fields. 4. Why use a curved vascular clamp? A curved vascular clamp can facilitate access around surrounding anatomical structures while maintaining a practical orientation of the instrument handles. 5. Is this DeBakey clamp suitable for cardiovascular surgery? Yes. It is specialized vascular instrumentation that may be incorporated into selected cardiovascular, vascular, and thoracic procedures according to surgical requirements. 6. What material is the DeBakey Acutely Curved Clamp made from? Professional reusable vascular clamps of this type are commonly manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 7. How should the DeBakey Acutely Curved Clamp be sterilized? When supplied as a reusable instrument, it should be cleaned, inspected, and sterilized according to the manufacturer’s validated instructions and the healthcare facility’s approved instrument-processing protocol.

Instrument name9 5/8″ DeBakey Acutely Curved Clamp
Catalogue referenceUS-58233
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image