

Catalogue reference: US-56073
The Adler Wound Gauge 2.0 & 2.5 mm Ranges Titanium is a precision ophthalmic measuring instrument designed to assess surgical wound dimensions. Its titanium construction provides a lightweight, durable solution for accurate measurement during cataract and anterior segment procedures.
Prefer Wise or bank transfer? Choose it at checkout.
The Adler Wound Gauge 2.0 & 2.5 mm Ranges Titanium is a specialized ophthalmic microsurgical instrument designed for accurate measurement and assessment of surgical wound dimensions. Featuring 2.0 mm and 2.5 mm measurement ranges, this precision gauge helps ophthalmic surgeons evaluate incision or wound size during delicate eye procedures. Its titanium construction provides a combination of low weight, strength, and corrosion resistance suitable for professional ophthalmic environments. Accurate wound measurement can be an important part of modern cataract and anterior segment surgery. Small-incision procedures require controlled surgical access, and a dedicated wound gauge provides the surgeon with a practical reference for assessing the dimensions of the incision. The Adler Wound Gauge is designed to help establish this measurement without relying solely on visual estimation. The 2.0 mm and 2.5 mm ranges make the instrument particularly relevant to microsurgical procedures involving small corneal or limbal incisions. These dimensions can be useful when evaluating surgical wounds associated with cataract procedures, phacoemulsification, micro-incision techniques, and other anterior segment applications. The exact use and measurement technique should be determined by the operating ophthalmologist according to the surgical procedure and clinical requirements. The gauge’s precision working end is designed to provide controlled contact with the surgical wound. Its measurement profile allows the surgeon to assess whether the wound corresponds to the intended dimensional range. This can support intraoperative decision-making and help maintain consistency during procedures where incision size is an important consideration. Titanium construction is a major advantage of this Adler wound gauge. Titanium offers an excellent strength-to-weight ratio, allowing the instrument to remain lightweight while providing the rigidity required for accurate measurement. Reduced instrument weight can also contribute to comfortable handling during prolonged microsurgical procedures. Titanium is additionally known for its resistance to corrosion and suitability for appropriately processed reusable medical instruments. The compact design is well suited to the restricted operative environment of ophthalmic surgery. The surgeon can position the gauge carefully at the intended wound site while maintaining control of the instrument. A properly balanced ophthalmic measuring tool provides useful tactile feedback and allows small adjustments to be made without unnecessary movement. The Adler Wound Gauge can be included in cataract, phacoemulsification, microphaco, refractive, and anterior segment surgical instrument sets. It can complement other ophthalmic instruments such as corneal markers, calipers, keratomes, forceps, scissors, speculums, wound manipulators, and intraocular lens implantation instruments. Measurement accuracy depends on the integrity and cleanliness of the working surfaces. If supplied as a reusable instrument, the gauge should be cleaned promptly after use according to the manufacturer’s validated instructions. The measurement edges and markings should be inspected for residue, deformation, scratches, or other damage that could affect measurement accuracy. Titanium instruments should be handled carefully during cleaning and storage to prevent damage to their precision surfaces. The Adler Wound Gauge should be stored in a manner that protects the measurement end from contact with other instruments. Sterilization should be performed using a validated ophthalmic instrument processing protocol and according to the manufacturer’s instructions. Proper cleaning, inspection, sterilization, and storage help preserve the gauge’s dimensional accuracy and extend its service life. The Adler Wound Gauge 2.0 & 2.5 mm Ranges Titanium combines precision measurement with lightweight titanium construction for modern ophthalmic microsurgery. Its specialized dimensions and durable design make it a useful addition to cataract, phacoemulsification, and anterior segment surgical instrument collections. Key Features Adler wound gauge designed for ophthalmic microsurgery Provides 2.0 mm and 2.5 mm measurement ranges Designed for precise surgical wound and incision assessment Suitable for cataract and anterior segment procedures Useful for evaluating small corneal or limbal surgical wounds Titanium construction provides lightweight handling Excellent strength-to-weight characteristics Corrosion-resistant construction with appropriate maintenance Compact profile suitable for confined ophthalmic surgical fields Supports controlled intraoperative dimensional assessment Suitable for phacoemulsification and micro-incision surgery sets Reusable construction where supplied as a reusable surgical instrument Product Specifications Specification Details Product Name Adler Wound Gauge 2.0 & 2.5 mm Ranges Instrument Type Ophthalmic Wound Measuring Gauge Measurement Ranges 2.0 mm and 2.5 mm Primary Application Ophthalmic Wound Measurement Typical Applications Cataract, Phacoemulsification and Anterior Segment Surgery Main Function Surgical Incision / Wound Assessment Material Surgical-Grade Titanium Key Material Benefit Lightweight, Strong and Corrosion Resistant Working End Precision Measurement Profile Surgical Specialty Ophthalmology Construction Reusable Surgical Instrument, where applicable Sterilization Validated Sterilization Process According to Manufacturer Instructions Intended Users Qualified Ophthalmic Surgeons and Healthcare Professionals FAQs 1. What is the Adler Wound Gauge used for? The Adler Wound Gauge is designed to measure and assess the dimensions of surgical wounds or incisions during ophthalmic procedures. 2. What measurement ranges does this Adler Wound Gauge provide? This model is specified with 2.0 mm and 2.5 mm ranges , making it suitable for assessment of small ophthalmic surgical incisions. 3. Is the Adler Wound Gauge suitable for cataract surgery? Yes. Its small measurement ranges can be useful during cataract, phacoemulsification, micro-incision, and other anterior segment procedures where wound dimensions need to be assessed. 4. Why is this wound gauge made from titanium? Titanium provides a lightweight yet strong construction, helping support precise instrument handling while offering good corrosion resistance for reusable surgical applications. 5. Can this wound gauge be used during phacoemulsification? It can be incorporated into appropriate phacoemulsification instrument sets when intraoperative assessment of incision or wound dimensions is required. 6. Can the Adler Wound Gauge be sterilized? When supplied as a reusable instrument, it should be cleaned, inspected, and sterilized using a validated ophthalmic instrument processing procedure according to the manufacturer’s instructions. 7. Why is precise wound measurement important in ophthalmic surgery? Accurate wound assessment can help the surgeon evaluate whether an incision corresponds to the intended surgical dimensions and support consistent intraoperative technique.
| Instrument name | Adler Wound Gauge 2.0 & 2.5 mm Ranges Titanium |
|---|---|
| Catalogue reference | US-56073 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.