General Surgery Instruments

B Artery Clamp 0.4 1.0mm Pair

Catalogue reference: US-59668

$80.00$56.00✓ In Stock

The B Artery Clamp 0.4–1.0mm Pair is a precision microvascular surgical instrument set designed for controlled handling and temporary occlusion of very small blood vessels. Supplied as a pair, these specialized artery clamps are suitable for selected microsurgical and vascular procedures requiring accurate vessel control.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The B Artery Clamp 0.4 1.0mm Pair is a specialized microvascular surgical instrument set designed for precise handling, positioning, and controlled temporary occlusion of very small blood vessels. With a specified working range of 0.4–1.0mm, this paired configuration is intended for delicate microsurgical applications where accurate manipulation of small-caliber vascular structures is essential. Microvascular procedures require specialized instruments that provide controlled mechanical action within a restricted operative field. The B Artery Clamp is designed to assist qualified surgical professionals with temporary control of appropriately sized vessels during selected vascular and microsurgical procedures. Its compact working configuration is intended for applications where conventional vascular clamps may be too large or unsuitable. The 0.4–1.0mm specification identifies the intended small-vessel working range of this artery clamp pair. Vessel dimensions can vary according to anatomy and surgical procedure, so selecting an appropriate instrument size is essential. The surgeon should determine whether this clamp is suitable for the target vessel, tissue characteristics, and intended surgical technique before use. Microvascular artery clamps can support temporary vessel control, isolation, positioning, and manipulation during selected surgical procedures. Depending on the clinical application, they may be incorporated into techniques involving small-vessel repair, reconstruction, replantation, or microsurgical anastomosis. The specific use, placement, and duration of vascular occlusion should always be determined by the operating surgeon according to established surgical practice. The paired configuration provides two matching B artery clamps. Having a pair available can be useful during procedures where two vascular structures require controlled handling or where sequential vessel manipulation is part of the surgical technique. It also allows the instruments to be organized as a dedicated pair within a microvascular surgical tray. The B-style configuration provides a specialized working profile for delicate vascular handling. Fine instrument control is particularly important when working with vessels measuring less than a few millimeters in diameter. The clamp should be positioned carefully and operated with appropriate force to support controlled interaction with the target vessel. Professional microvascular artery clamps are commonly manufactured from surgical-grade stainless steel or other suitable precision surgical materials. Stainless steel provides strength, durability, and corrosion resistance while supporting appropriate cleaning and sterilization processes. Exact material specifications should be confirmed against the manufacturer’s documentation for the specific instrument. The B Artery Clamp 0.4–1.0mm Pair can be incorporated into microsurgery instrument sets, vascular surgery trays, reconstructive surgery collections, and specialized small-vessel surgical systems. It can complement other microvascular instruments such as approximator clamps, fine forceps, microsurgical needle holders, vascular dilators, and specialized scissors. Careful maintenance is essential for precision microvascular instrumentation. After use, each clamp should be cleaned promptly according to the manufacturer’s validated cleaning instructions. Particular attention should be given to the fine working ends and moving components to prevent biological material or residue from remaining on precision surfaces. Abrasive materials and improper mechanical handling should be avoided when they could damage the instrument. After cleaning, the clamps should be thoroughly rinsed and dried before inspection. Each instrument should be checked for correct alignment, smooth movement, structural integrity, corrosion, and deformation. Any clamp showing damage or abnormal mechanical performance should be removed from clinical service and assessed by qualified personnel. Sterilization should be performed according to the manufacturer’s validated instructions and the healthcare facility’s approved sterilization protocol. Proper cleaning before sterilization is essential for effective reprocessing. Following sterilization, the pair should be stored carefully to protect the delicate working ends from impact, bending, moisture, and contamination. The B Artery Clamp 0.4–1.0mm Pair provides a specialized solution for professional surgical teams requiring precise small-vessel control. Its defined working range, paired configuration, and microvascular design make it a practical addition to specialized microsurgical and vascular instrument collections. Key Features B-style microvascular artery clamp configuration Supplied as a pair Designed for vessels in the 0.4–1.0mm range Suitable for delicate small-vessel surgical applications Designed for controlled temporary vascular occlusion Supports precise vessel positioning and manipulation Useful for selected microsurgical procedures Suitable for small-vessel repair and anastomotic techniques Compact working profile for restricted operative fields Precision-oriented design for delicate vascular handling Suitable for specialized microsurgery instrument sets Designed for appropriate cleaning and sterilization procedures Product Specifications Specification Details Product Name B Artery Clamp Instrument Type Microvascular Artery Clamp Configuration B Style, Pair Working Range 0.4–1.0mm Quantity 2 Pieces Primary Function Small-vessel control and temporary occlusion Surgical Specialty Microsurgery, Vascular Surgery Application Delicate vascular procedures Instrument Category Microvascular Surgical Instrument Construction Precision surgical instrument material Reusable Subject to manufacturer specifications Sterilization According to validated sterilization protocols Intended Use Professional surgical applications FAQs 1. What is the B Artery Clamp 0.4–1.0mm Pair used for? It is designed for controlled handling, positioning, and temporary occlusion of appropriately sized small blood vessels during selected microsurgical and vascular procedures. 2. What vessel size is this B Artery Clamp designed for? The specified working range is 0.4–1.0mm, making it suitable for selected very small-caliber vascular structures. 3. How many B Artery Clamps are included? This product is supplied as a pair, providing two B-style microvascular artery clamps. 4. Is the B Artery Clamp suitable for microsurgery? Yes. Its fine 0.4–1.0mm working range and specialized configuration make it suitable for selected microvascular and microsurgical applications. 5. What is the purpose of a microvascular artery clamp? A microvascular artery clamp can provide temporary control, positioning, or occlusion of an appropriately sized blood vessel during selected surgical techniques. 6. Why is the 0.4–1.0mm range important? The range helps surgical professionals identify an instrument intended for very small vessels. Final instrument selection should be based on vessel anatomy and the surgical procedure. 7. What material is used to manufacture the B Artery Clamp? Precision microvascular clamps are commonly manufactured from surgical-grade stainless steel or another suitable surgical instrument material. Exact material specifications should be confirmed with the manufacturer.

Instrument nameB Artery Clamp 0.4 1.0mm Pair
Catalogue referenceUS-59668
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image