General Surgery Instruments

Blalock Valve Hook Cardiovascular & Thoracic Valve Hook

Catalogue reference: US-54775

$80.00$56.00✓ In Stock

The Blalock Valve Hook Cardiovascular & Thoracic Valve Hook is a specialized surgical instrument designed for controlled manipulation and exposure of cardiac valve structures. Its focused working end supports precise handling during cardiovascular and cardiothoracic procedures.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The Blalock Valve Hook Cardiovascular & Thoracic Valve Hook is a specialized cardiovascular surgical instrument designed for controlled manipulation, positioning, and exposure of cardiac valve structures during appropriate open-heart and cardiothoracic procedures. Its dedicated hook profile provides a focused working point that can assist the surgeon with controlled retraction or manipulation of suitable anatomical tissue during valve-related surgery. Cardiac valve procedures require instruments that provide accurate access to delicate anatomical structures while maintaining clear visualization of the operative field. A specialized valve hook can support these requirements by allowing the surgeon to engage and gently manipulate selected tissue without using a broad or bulky working end. The Blalock Valve Hook features a focused hook-shaped working end designed for controlled engagement. The hook can assist with positioning or gently retracting appropriate tissue to improve access to the valve and surrounding structures. Its specialized shape allows the instrument to be positioned precisely within the operative field. The instrument may be incorporated into cardiovascular, cardiac, thoracic, and cardiothoracic surgical instrument sets . Potential applications include valve exposure, tissue positioning, cardiac structure manipulation, and selected procedures involving surgical access to cardiac valves. The exact application should always be determined by the operating surgeon based on the patient’s anatomy and the specific procedure. One of the principal benefits of a valve hook is its ability to provide localized tissue control . Instead of applying pressure over a broad surface, the hook can engage a selected anatomical point. This can support precise positioning when visibility or access around a cardiac valve is limited. Because cardiac tissues are delicate, controlled force and appropriate instrument selection are essential. The Blalock Valve Hook should be used only on anatomical structures appropriate for its design and according to established surgical technique. Excessive traction or force should be avoided to reduce the risk of unnecessary tissue injury. The instrument is typically manufactured from surgical-grade stainless steel , providing strength, durability, and corrosion resistance suitable for professional reusable surgical instrumentation. Precision manufacturing helps preserve the geometry and integrity of the hook during repeated use, cleaning, and sterilization. The handle is designed to provide controlled manual manipulation. A balanced shaft allows the surgeon to direct the working end accurately while maintaining a stable grip. The focused hook profile can be particularly useful when working within the confined environment of an open cardiac operative field. Before use, the valve hook should be inspected for deformation, sharp edges, cracks, corrosion, or other surface damage. The working hook should retain its intended shape and should not be bent or modified. Any instrument showing structural damage should be removed from service and evaluated by qualified surgical instrument maintenance personnel. After use, the instrument should be cleaned promptly to prevent blood and tissue from drying on the working surface. Particular attention should be paid to the hook tip and shaft junction , where biological material may accumulate. Thorough rinsing, drying, inspection, and validated sterilization should be performed according to institutional protocols and manufacturer recommendations. Proper storage is also important for maintaining the working-end geometry. The hook should be protected from impact and should not be stored in a way that places pressure on the tip. Routine inspection before each procedure helps ensure that the instrument remains mechanically and structurally suitable for use. Overall, the Blalock Valve Hook provides a precise solution for controlled cardiac valve exposure and tissue manipulation. Its focused hook design, durable stainless steel construction, and specialized cardiovascular application make it a useful addition to professional cardiac and thoracic surgical instrument sets. Key Features Specialized Blalock cardiovascular valve hook Designed for cardiac valve exposure and manipulation Focused hook-shaped working end Supports controlled tissue positioning and retraction Useful in valve-related cardiovascular procedures Suitable for thoracic and cardiothoracic surgery Compact working profile for confined operative fields Provides precise localized tissue control Ergonomic manual handling Surgical-grade stainless steel construction Durable and corrosion-resistant with proper maintenance Suitable for reusable professional surgical instrumentation Product Specifications Specification Details Product Name Blalock Valve Hook Instrument Type Cardiovascular / Valve Hook Working End Hook-Shaped Primary Function Valve Exposure & Tissue Manipulation Surgical Specialty Cardiovascular & Thoracic Surgery Application Cardiac Valve Procedures Working Profile Focused / Precision Operation Manual Material Surgical-Grade Stainless Steel Reusable Yes, with appropriate reprocessing Sterilization Validated surgical instrument sterilization methods Intended Users Qualified Surgical Professionals FAQs 1. What is a Blalock Valve Hook used for? A Blalock Valve Hook is designed for controlled manipulation, positioning, and exposure of appropriate cardiac valve structures during cardiovascular and cardiothoracic procedures. 2. What is the purpose of the hook-shaped tip? The focused hook allows the surgeon to engage and gently manipulate selected tissue at a localized point, supporting exposure and visualization of the operative area. 3. Is the Blalock Valve Hook used in cardiac surgery? Yes. It is designed for appropriate cardiac and cardiovascular procedures involving valve exposure or controlled tissue manipulation. 4. Can this valve hook be used during thoracic procedures? Yes. It may be incorporated into suitable thoracic and cardiothoracic surgical instrument sets where controlled cardiac tissue manipulation is required. 5. What type of tissue can a valve hook manipulate? It should only be used on anatomical structures appropriate for the instrument’s design and according to the operating surgeon’s established surgical technique. 6. What material is the Blalock Valve Hook made from? The instrument is typically manufactured from surgical-grade stainless steel , providing durability and corrosion resistance with appropriate care. 7. Is the Blalock Valve Hook reusable? Yes. It is intended for reusable professional surgical use when properly cleaned, inspected, maintained, and sterilized using validated procedures.

Instrument nameBlalock Valve Hook Cardiovascular & Thoracic Valve Hook
Catalogue referenceUS-54775
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image