General Surgery Instruments

Coblation Turbinator Wand

Catalogue reference: US-31468

$190.00$133.00✓ In Stock

The Coblation Turbinator Wand is a specialized ENT surgical wand designed for controlled submucosal reduction of hypertrophic turbinates. It supports precise tissue ablation and hemostasis during turbinate reduction procedures, helping ENT surgeons manage nasal airway obstruction related to enlarged turbinates.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The Coblation Turbinator Wand is a professional ENT surgical instrument developed for minimally invasive turbinate reduction procedures. It is designed to reduce hypertrophic turbinates submucosally while supporting hemostasis through built-in bipolar coagulation. Smith+Nephew describes the TURBINATOR◊ Wand as a device intended for submucosal turbinate reduction with integrated coagulation support. Using COBLATION◊ plasma technology, the wand helps remove targeted soft tissue through controlled radiofrequency plasma energy. Smith+Nephew explains that COBLATION technology creates a plasma field that breaks down tissue molecules through a chemical ablation process, supporting precise soft-tissue removal. The slim transnasal design allows the surgeon to access the turbinate area through the nasal passage and treat tissue beneath the mucosal surface. This makes the wand suitable for inferior turbinate reduction procedures where controlled tissue removal, visibility, and bleeding management are important. Depending on the model and system configuration, the Coblation Turbinator Wand may include saline delivery, suction support, and bipolar coagulation features. Smith+Nephew product materials describe saline delivery and targeted hemostasis as part of the TURBINATOR wand system. This device is intended for use by trained ENT surgeons and qualified medical professionals in hospitals, ENT clinics, outpatient surgical centers, and operating-room environments. Generator compatibility, sterility, packaging, and exact technical specifications should be confirmed with the manufacturer or supplier before ordering. Key Features Designed for turbinate reduction procedures Supports submucosal reduction of hypertrophic turbinates COBLATION plasma technology for controlled soft-tissue ablation Built-in bipolar coagulation for hemostasis support Slim transnasal profile for nasal cavity access Helps preserve controlled treatment of targeted turbinate tissue May include saline delivery depending on system configuration Suitable for ENT and nasal airway procedures Designed for hospital, clinic, and outpatient surgical use Intended for trained ENT professionals only Standard Specifications Specification Details Product Name Coblation Turbinator Wand Instrument Type ENT Coblation / RF Plasma Wand Application Turbinate reduction Primary Use Submucosal reduction of hypertrophic turbinates Function Soft-tissue ablation and hemostasis support Technology COBLATION / radiofrequency plasma technology Coagulation Built-in bipolar coagulation, depending on model Access Route Transnasal Use Area Inferior turbinate / nasal airway region Saline Delivery Model dependent Generator Compatibility Compatible COBLATION / RF controller required Sterility Usually sterile single-use, depending on manufacturer User Qualified ENT surgeons and trained medical professionals Applications Inferior turbinate reduction Hypertrophic turbinate treatment support Nasal airway obstruction procedures where clinically indicated ENT soft-tissue ablation Submucosal turbinate tissue reduction Hemostasis support during turbinate procedures Outpatient ENT surgical procedures Hospital and clinic-based nasal surgery FAQs What is a Coblation Turbinator Wand used for? A Coblation Turbinator Wand is used for controlled submucosal reduction of hypertrophic turbinates during ENT turbinate reduction procedures. Does the wand support coagulation? Yes. Smith+Nephew describes the TURBINATOR Wand as having built-in bipolar coagulation to support hemostasis during turbinate reduction. How does coblation technology work? Coblation technology uses radiofrequency energy to create a plasma field that ablates targeted soft tissue through a molecular breakdown process. Is it used through the nose? Yes. The wand is designed for transnasal access during turbinate reduction procedures. Does it require a generator? Yes. A Coblation Turbinator Wand must be used with a compatible coblation or radiofrequency controller system. Compatibility depends on the specific wand model and manufacturer. Is the wand reusable? Many coblation wands are supplied as sterile single-use devices, but the exact sterility and reuse status should be confirmed with the supplier or manufacturer before purchase. Who should operate this device? This device should only be used by trained ENT surgeons or qualified medical professionals in an appropriate clinical or surgical environment.

Instrument nameCoblation Turbinator Wand
Catalogue referenceUS-31468
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image