General Surgery Instruments

Cooley Acutely Cvd Clamp Med Jaw

Catalogue reference: US-57807

$80.00$56.00✓ In Stock

The Cooley Acutely Curved Clamp Med Jaw is a specialized vascular surgical instrument designed for controlled clamping and manipulation of blood vessels. Its acutely curved profile and medium jaw configuration provide angled access and precise handling in selected cardiovascular procedures.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The Cooley Acutely Cvd Clamp Med Jaw is a specialized vascular surgical instrument designed for controlled temporary occlusion, positioning, and manipulation of blood vessels during appropriately indicated cardiovascular and vascular procedures. Its acutely curved configuration provides a specialized approach to vascular structures, while the medium jaw offers a defined working size for selected surgical applications. Cooley vascular clamps are designed for procedures where precise vessel control is essential. The acutely curved configuration allows the working end to approach vascular structures from an angled direction rather than requiring a completely straight approach. This can be particularly useful when surrounding anatomy, retractors, grafts, or other instruments restrict direct access to the target vessel. The acutely curved design is the primary functional characteristic of this clamp. The pronounced curvature can provide improved positioning around appropriately selected vessels while helping maintain practical clearance from adjacent anatomical structures. This geometry may allow the surgeon to place the working end in a suitable orientation while maintaining controlled hand positioning through the instrument handles. The medium jaw configuration provides a specified working size for vascular applications where a smaller or larger clamp may not be appropriate. Jaw dimensions should always be matched to the target vessel, patient anatomy, and surgical technique. Qualified surgical personnel should determine the appropriate instrument based on the requirements of the procedure. A Cooley acutely curved clamp may be incorporated into professional cardiovascular surgery, vascular reconstruction, thoracic surgery, and specialty vascular procedures . Depending on the specific surgical technique, it can support temporary vessel occlusion, vascular manipulation, positioning, or controlled exposure. Its specialized configuration makes it particularly useful when an angled approach is preferred. Smooth mechanical operation and accurate jaw alignment are important for reliable vascular instrumentation. The working jaws should open and close smoothly and maintain appropriate alignment throughout the operating range. Proper application and controlled pressure are essential when working with delicate vascular structures. The clamp should not be forcibly bent, twisted, or used outside its intended purpose. Professional reusable vascular clamps are commonly manufactured from surgical-grade stainless steel , selected for strength, durability, and corrosion resistance when properly maintained. Precision manufacturing helps preserve the intended acute curvature, jaw configuration, and mechanical performance through repeated clinical use. After use, the Cooley Acutely Curved Clamp should be cleaned promptly according to the manufacturer’s validated instructions and the healthcare facility’s approved instrument-reprocessing protocol. Blood and tissue residue should be thoroughly removed from the jaws, curved working end, hinge, and accessible surfaces. The instrument should then be rinsed, dried, inspected, and sterilized using a validated process compatible with the instrument. Before reuse, trained personnel should inspect the clamp for jaw alignment, curvature integrity, smooth opening and closing, corrosion, surface damage, and structural condition . Particular attention should be given to the acutely curved working end because deformation may affect the intended surgical approach. Any instrument showing abnormal movement, deformation, or excessive wear should be removed from service and evaluated according to institutional procedures. The Cooley Acutely Curved Clamp Med Jaw combines specialized Cooley-style vascular design with an acutely curved working profile for controlled vessel handling. It is a practical addition to professional Cooley vascular clamps, acutely curved vascular clamps, cardiovascular surgical instruments, vascular surgery clamps, and specialty vascular instrument sets . Key Features Cooley-style vascular clamp for specialized surgical applications. Acutely curved working profile facilitates angled vascular access. Medium jaw configuration for appropriately selected vessels. Designed for controlled temporary vascular occlusion. Supports precise vessel positioning and manipulation. Curved geometry provides useful clearance around adjacent anatomy. Suitable for selected cardiovascular and vascular procedures. Useful for vascular reconstruction and thoracic surgical sets. Surgical-grade stainless steel construction supports durability. Designed for controlled mechanical operation. Requires inspection of jaw alignment and curvature before use. Reprocessing should follow validated manufacturer and facility protocols. Product Specifications Specification Details Product Name Cooley Acutely Curved Clamp Instrument Type Vascular Clamp Jaw Configuration Medium Working Profile Acutely Curved Design Cooley Type Primary Function Vascular clamping and manipulation Primary Application Temporary vascular occlusion Applications Cardiovascular, vascular, thoracic surgery Working End Acutely curved Material Surgical-grade stainless steel Reusable Yes, when supplied as a reusable instrument Sterilization Follow manufacturer-validated instructions Intended Users Trained surgical professionals FAQs 1. What is the Cooley Acutely Curved Clamp used for? It is designed for controlled temporary vascular occlusion, positioning, and manipulation during appropriately selected cardiovascular and vascular procedures. 2. What does acutely curved mean on a vascular clamp? It describes a pronounced curvature in the working profile, allowing the clamp to approach vascular structures from a specialized angle. 3. What does the medium jaw configuration indicate? The medium jaw identifies the specified working size and should be matched to the target vessel and requirements of the surgical procedure. 4. Why use an acutely curved vascular clamp? The curved configuration can facilitate access around surrounding anatomy and provide a more suitable approach when a straight clamp is less practical. 5. Is this Cooley clamp suitable for cardiovascular surgery? It may be incorporated into selected cardiovascular and vascular procedures requiring controlled vessel occlusion or manipulation, according to the surgeon’s technique. 6. What material is the Cooley Acutely Curved Clamp made from? Professional reusable vascular clamps of this type are commonly manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 7. How should the Cooley Acutely Curved Clamp be sterilized? When supplied as a reusable instrument, it should be cleaned, inspected, and sterilized according to the manufacturer’s validated instructions and the healthcare facility’s approved instrument-processing protocol.

Instrument nameCooley Acutely Cvd Clamp Med Jaw
Catalogue referenceUS-57807
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image