General Surgery Instruments

Cooley Acutely Cvd Clamp Small Ligature Carrier

Catalogue reference: US-57806

$80.00$56.00✓ In Stock

The Cooley Acutely Cvd Clamp Small Ligature Carrier is a specialized surgical instrument designed for controlled ligature handling and placement in vascular procedures. Its acutely curved configuration and small ligature carrier support precise access in confined operative fields.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The Cooley Acutely Cvd Clamp Small Ligature Carrier is a specialized surgical instrument designed to assist with controlled ligature handling and placement during appropriately indicated vascular and cardiovascular procedures. Its Cooley-style acutely curved configuration provides an angled approach to the operative field, while the small ligature carrier is designed for precise manipulation of ligature material in areas where direct access may be limited. Ligature carriers are specialized instruments used to grasp, guide, or position suture or ligature material around anatomical structures. In vascular surgery, accurate placement can be important when working within confined operative fields or around vessels and other delicate structures. The Cooley design provides a specialized working profile intended to facilitate controlled access and manipulation. The defining feature of this instrument is its acutely curved configuration . The pronounced curve allows the working end to approach the target area from an angled direction rather than requiring a straight-line approach. This can be useful when surrounding anatomy, retractors, grafts, or other instruments restrict direct access. The curved profile can also provide additional clearance around adjacent structures. The small ligature carrier provides a compact working end for handling appropriately sized ligature material. Its smaller configuration may be useful when precise placement is required in a restricted surgical field. The instrument should be matched to the size and type of ligature material specified for the procedure, with selection determined by qualified surgical personnel. The Cooley Acutely Curved Clamp Small Ligature Carrier may be incorporated into professional vascular surgery, cardiovascular surgery, thoracic surgery, and specialty surgical instrument sets . Depending on the specific operative technique, it can assist with ligature positioning, controlled tissue or vessel handling, and access around structures requiring specialized instrumentation. The curved working profile can provide improved maneuverability in anatomically challenging locations. By changing the angle between the handles and working end, the instrument may allow the surgeon to maintain a practical hand position while directing the carrier toward the intended site. This can be particularly useful where a straight ligature instrument would provide less suitable access. Smooth mechanical operation and accurate working-end alignment are essential for reliable performance. The small carrier should engage and release ligature material predictably without excessive movement. The instrument should be used only for its intended function and should not be forcibly bent, twisted, or used to grasp materials beyond its designed capacity. Professional reusable surgical instruments of this type are commonly manufactured from surgical-grade stainless steel , selected for strength, durability, and corrosion resistance when properly maintained. Precision manufacturing helps preserve the intended acute curvature and small working-end geometry through repeated clinical use. After use, the Cooley Acutely Cvd Clamp Small Ligature Carrier should be cleaned promptly according to the manufacturer’s validated instructions and the healthcare facility’s approved instrument-reprocessing protocol. Biological residue and retained material should be thoroughly removed from the working end, hinge, curved shaft, and accessible surfaces. The instrument should then be rinsed, dried, inspected, and sterilized using a validated process compatible with the instrument. Before reuse, trained personnel should inspect the instrument for working-end alignment, carrier integrity, smooth opening and closing, curvature, corrosion, and surface damage . Particular attention should be given to the small carrier tip to ensure it has not been bent or deformed. Any instrument showing excessive wear or impaired mechanical function should be removed from service and evaluated according to institutional procedures. The Cooley Acutely Cvd Clamp Small Ligature Carrier combines a specialized acutely curved profile with a compact ligature-carrying working end for controlled surgical handling. It is a useful addition to professional Cooley surgical instruments, acutely curved ligature carriers, vascular surgery instruments, cardiovascular surgical instruments, and specialty surgical sets . Key Features Cooley-style design for specialized surgical access. Acutely curved profile facilitates angled approach to the operative field. Small ligature carrier supports precise ligature handling. Designed for controlled placement and manipulation of ligature material. Compact working end is useful in confined surgical fields. Curved configuration provides clearance around adjacent structures. Suitable for selected vascular and cardiovascular procedures. Useful for thoracic and specialty surgical instrument sets. Surgical-grade stainless steel construction supports durability. Designed for controlled mechanical movement and precise handling. Requires inspection of the small carrier tip before use. Reprocessing should follow validated manufacturer and facility protocols. Product Specifications Specification Details Product Name Cooley Acutely Curved Clamp Instrument Type Ligature Carrier / Surgical Clamp Design Cooley Type Working Profile Acutely Curved Carrier Configuration Small Primary Function Ligature handling and placement Applications Vascular, cardiovascular, thoracic surgery Working End Small ligature carrier Access Profile Angled / Curved Material Surgical-grade stainless steel Reusable Yes, when supplied as a reusable instrument Sterilization Follow manufacturer-validated instructions Intended Users Trained surgical professionals FAQs 1. What is the Cooley Acutely Curved Small Ligature Carrier used for? It is designed for controlled handling, guidance, and placement of appropriate ligature material during selected vascular and cardiovascular surgical procedures. 2. What does the acutely curved design provide? The pronounced curvature provides an angled approach to the operative field and can facilitate access around surrounding anatomical structures. 3. What is a small ligature carrier? A small ligature carrier is a compact surgical working end designed to assist with precise manipulation and placement of appropriately sized ligature material. 4. Is this instrument used in vascular surgery? It may be incorporated into selected vascular, cardiovascular, and thoracic procedures where controlled ligature handling is required. 5. Why is a curved ligature carrier useful? A curved configuration can improve access to confined or difficult-to-reach areas while allowing the surgeon to maintain practical hand positioning. 6. What material is the Cooley Ligature Carrier made from? Professional reusable instruments of this type are commonly manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 7. How should the Cooley Small Ligature Carrier be sterilized? When supplied as a reusable instrument, it should be cleaned, inspected, and sterilized according to the manufacturer’s validated instructions and the healthcare facility’s approved instrument-processing protocol.

Instrument nameCooley Acutely Cvd Clamp Small Ligature Carrier
Catalogue referenceUS-57806
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image