

Catalogue reference: US-70510
Davis Ring Size 4 Blades Only Left is a reusable replacement blade designed for compatible Davis Ring mouth gag systems. The left-sided Size 4 blade provides controlled oral retraction and is suitable for professional ENT and oral surgical applications.
Prefer Wise or bank transfer? Choose it at checkout.
The Davis Ring Size 4 Blades Only Left is a replacement blade designed for use with compatible Davis Ring mouth gag systems. As a left-sided Size 4 component, it is intended to provide controlled retraction and exposure within the oral cavity during procedures where stable positioning of the tongue and surrounding tissues is required. The product is listed as a reusable mouth-gag component and is identified as an adjustable, reusable mouth gag accessory. This blade-only configuration is useful for facilities that need to replace an individual Davis Ring blade rather than purchase a complete retractor assembly. Selecting the correct blade size and left/right configuration is important for maintaining compatibility with the corresponding Davis Ring system. The Size 4 left configuration is specifically cataloged as model 3734087, distinguishing it from the matching Size 4 right blade, model 3734088. The blade is designed to work as part of a ring-style oral retraction system, helping provide consistent access and visualization during appropriate oral, tonsillar, pharyngeal, and related ENT procedures. Its controlled profile allows the surgeon or operating team to position the compatible retractor according to the requirements of the procedure while maintaining stable tissue retraction. For healthcare facilities maintaining reusable surgical instrumentation, a replacement blade can also help keep existing equipment serviceable when an individual component requires replacement. The blade-only format makes it particularly suitable for instrument inventories where different Davis Ring blade sizes and configurations are maintained for varying procedural requirements. As with other reusable surgical instruments, the blade should be thoroughly cleaned, inspected, and processed according to the applicable manufacturer’s validated instructions before reuse. Particular attention should be given to the blade surface, attachment area, and any locking or connection points to ensure that the component remains clean, functional, and suitable for its intended use. The Davis Ring Size 4 Blades Only Left is therefore a practical replacement component for compatible Davis Ring systems, combining a specific Size 4 configuration with left-sided positioning for professional surgical use. Key Features Davis Ring Size 4 replacement blade Left-sided configuration Blade-only component Designed for compatible Davis Ring mouth gag systems Reusable surgical instrument component Supports controlled oral cavity retraction Suitable for appropriate ENT and oral surgical applications Helps maintain consistent surgical exposure Useful for replacement and instrument maintenance Professional surgical instrument design Model/catalog number 3734087 Requires compatibility verification before use Product Specifications Specification Details Product Name Davis Ring Size 4 Blades Only Left Instrument Type Davis Ring Replacement Blade Size 4 Side Left Configuration Blade Only Reusable Yes Application Oral & ENT Surgical Procedures Device Type Adjustable Reusable Mouth Gag Component Model / Catalog Number 3734087 Compatibility Compatible Davis Ring Mouth Gag System FAQs 1. What is the Davis Ring Size 4 Blades Only Left used for? It is a replacement blade for a compatible Davis Ring mouth gag system and is intended to provide controlled oral retraction during appropriate surgical procedures. 2. Is this a complete Davis Ring mouth gag? No. This product is the Size 4 left blade only and does not represent a complete mouth gag assembly. 3. Is the Davis Ring Size 4 Left blade reusable? Yes. The corresponding device is identified as a reusable mouth gag component. Proper cleaning, inspection, and sterilization should follow the applicable manufacturer’s instructions. 4. What is the model number for this Size 4 left blade? The verified model/catalog number for the Davis Ring Size 4 Left blade is 3734087 . 5. What is the difference between Size 4 Left and Size 4 Right? The primary distinction is the side configuration. Size 4 Left is model 3734087, while the corresponding Size 4 Right configuration is model 3734088. 6. Can this blade be used with any mouth gag? Compatibility should be confirmed before use. It is intended for the corresponding Davis Ring system rather than universal use with unrelated mouth gags. 7. How should the blade be maintained? Because it is a reusable surgical component, it should be cleaned, inspected, and sterilized using validated procedures and the applicable manufacturer’s instructions before reuse.
| Instrument name | Davis Ring Size 4 Blades Only Left |
|---|---|
| Catalogue reference | US-70510 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.