

Catalogue reference: US-56681
The Harms Trabeculotome Right Left Round Knurled Handle is a precision ophthalmic surgical instrument designed for controlled access and incision of the trabecular meshwork during trabeculotomy procedures. Right- and left-sided configurations provide procedural versatility, while the knurled round handle supports secure, controlled handling.
Prefer Wise or bank transfer? Choose it at checkout.
The Harms Trabeculotome Right Left Round Knurled Handle is a specialized ophthalmic microsurgical instrument designed for controlled incision and manipulation of the trabecular meshwork during appropriate glaucoma surgery procedures. Trabeculotomy requires precise access to the anterior chamber angle and careful manipulation of delicate ocular structures. A dedicated trabeculotome provides the surgeon with a purpose-designed working end for performing the intended surgical maneuver. This Harms trabeculotome is available in right and left configurations , allowing the surgeon to select the appropriate orientation according to the operative side, approach, and preferred surgical technique. Having appropriately oriented instruments can help support controlled access and reduce unnecessary instrument repositioning during delicate angle surgery. The working end is designed for use within the anterior chamber angle and is intended to facilitate controlled entry and movement through the trabecular meshwork. The exact geometry and dimensions of the working tip may vary according to the specific manufacturer and model. Proper instrument selection and handling are essential because the trabecular meshwork and adjacent ocular structures are delicate. The round knurled handle provides an ergonomic gripping surface designed to improve tactile control. Knurling creates a textured surface that can enhance finger contact and reduce unwanted slipping, particularly when precise rotational or directional movements are required. The round profile allows the surgeon to manipulate the instrument from different hand positions according to surgical preference. Trabeculotomy is performed to improve aqueous humor outflow through the trabecular pathway in appropriately selected glaucoma cases. The instrument itself does not determine the clinical indication; rather, the surgeon selects the procedure based on the patient’s diagnosis, anatomy, and overall treatment plan. The Harms Trabeculotome is intended to support the mechanical component of the procedure. The Harms Trabeculotome Right Left Round Knurled Handle is generally manufactured from surgical-grade stainless steel or another suitable medical-grade material when supplied as a reusable instrument. Stainless steel provides strength, durability, and corrosion resistance while supporting validated cleaning and sterilization processes. The fine working tip should be carefully inspected before each procedure. The surgeon or instrument technician should verify that the tip is correctly formed, free from deformation or corrosion, and securely aligned with the shaft. Any damage that could affect the instrument’s precision should be evaluated before clinical use. After use, the trabeculotome should be cleaned promptly according to validated ophthalmic instrument-processing procedures. Biological residue should not be allowed to dry on the working end. The instrument should be thoroughly cleaned, rinsed, dried, inspected, and sterilized according to the manufacturer’s validated instructions and the healthcare facility’s infection-control protocol. Particular care should be taken to protect the fine working tip during cleaning, transportation, and storage. The instrument should not be placed under excessive pressure or allowed to contact heavier instruments. Dedicated ophthalmic trays or protective holders can help preserve the tip’s geometry and overall condition. The Harms Trabeculotome Right Left Round Knurled Handle provides ophthalmic surgeons with a specialized instrument for controlled trabecular meshwork manipulation. Its right- and left-sided options, precision working profile, and secure knurled handle make it a practical component of professional glaucoma and ophthalmic microsurgical instrument sets. Key Features Specialized trabeculotome for ophthalmic glaucoma surgery Available in right and left configurations Designed for controlled trabecular meshwork incision and manipulation Precision working tip for anterior chamber angle procedures Round knurled handle provides enhanced finger grip Textured handle supports controlled rotational and directional movement Suitable for delicate ophthalmic microsurgical techniques Surgical-grade stainless steel construction, where applicable Durable and corrosion-resistant design for professional use Fine working tip requires routine inspection for alignment and damage Suitable for glaucoma and ophthalmic surgical instrument sets Compatible with validated cleaning and sterilization procedures Product Specifications Specification Details Product Name Harms Trabeculotome Right Left Round Knurled Handle Instrument Type Ophthalmic Trabeculotome Specialty Ophthalmology / Glaucoma Surgery Primary Function Trabecular Meshwork Incision and Manipulation Configuration Right and Left Handle Type Round Knurled Handle Working End Trabeculotome Tip Surgical Application Trabeculotomy / Angle Surgery Material Surgical-Grade Stainless Steel or Medical-Grade Material Construction Reusable, where applicable Handling Precision Microsurgical Handling Surface Smooth Surgical Finish with Knurled Grip Maintenance Cleaning, Inspection, Drying, and Sterilization as Applicable Sterilization According to manufacturer instructions and validated facility protocols Intended Users Qualified Ophthalmic Surgeons and Surgical Professionals FAQs What is a Harms Trabeculotome? A Harms Trabeculotome is a specialized ophthalmic surgical instrument designed to facilitate controlled manipulation and incision of the trabecular meshwork during appropriate trabeculotomy procedures. What is a trabeculotome used for? A trabeculotome is used during selected glaucoma procedures to access and manipulate the trabecular meshwork as part of a surgical approach intended to improve aqueous humor outflow. Why are right and left trabeculotomes available? Right- and left-sided configurations provide different working orientations, allowing the surgeon to select the instrument that best matches the operative side and surgical approach. What is the benefit of a round knurled handle? The round knurled handle provides a textured gripping surface that can improve finger contact and support controlled manipulation of the instrument during delicate microsurgery. What material is the Harms Trabeculotome made from? Reusable professional models are commonly manufactured from surgical-grade stainless steel or another appropriate medical-grade material. Exact specifications should be confirmed with the manufacturer. Is the Harms Trabeculotome reusable? When supplied as a reusable surgical instrument, it can be cleaned, inspected, and sterilized between procedures according to the manufacturer’s instructions and institutional protocols. How should a trabeculotome be maintained? The instrument should be cleaned promptly after use, carefully inspected for tip damage or deformation, dried thoroughly, and sterilized using a validated process compatible with the instrument. What should be checked before using a Harms Trabeculotome? The working tip should be inspected for proper shape, alignment, corrosion, surface damage, and secure attachment before the instrument is used clinically.
| Instrument name | Harms Trabeculotome Right Left Round Knurled Handle |
|---|---|
| Catalogue reference | US-56681 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.