

Catalogue reference: US-38292
MIS Penfield Dissector – Pull, 10 5/8″, #4, 4 mm, Curved Down, Panther is a specialized minimally invasive spinal surgery instrument designed for precise tissue dissection, neural structure manipulation, and controlled retraction during microsurgical procedures. Featuring a No. 4 Penfield-style 4 mm working tip, a curved-down configuration, Panther handle design, and a 10 5/8-inch overall length, this reusable and autoclavable dissector provides enhanced access, exceptional control, and reliable performance in minimally invasive surgical applications.
Prefer Wise or bank transfer? Choose it at checkout.
MIS Penfield Dissector – Pull, 10 5/8″, #4, 4 mm, Curved Down, Panther is a precision microsurgical instrument commonly used by spine surgeons, neurosurgeons, and minimally invasive surgery specialists during spinal decompression and other minimally invasive procedures. The instrument is specifically designed for atraumatic tissue dissection, nerve root mobilization, and controlled separation of anatomical planes within narrow surgical corridors. Its No. 4 Penfield-style working tip features a 4 mm profile that enables efficient manipulation of neural structures and soft tissues while minimizing trauma to surrounding anatomy. Featuring a curved-down working end, the dissector improves access and visualization within deep operative fields and facilitates precise instrument positioning around critical anatomical structures. The downward curvature is particularly useful for tissue mobilization and controlled dissection beneath neural elements. The pull-style configuration is optimized for controlled tissue retraction and dissection during minimally invasive procedures, allowing surgeons to perform precise maneuvers through tubular retractors and limited-access approaches. The Panther handle design provides enhanced ergonomics, ensuring a secure grip and superior tactile feedback throughout prolonged procedures. With an overall length of 10 5/8 inches (approximately 27 cm), the instrument offers extended reach for use in deep operative sites. Manufactured from premium surgical-grade stainless steel, the MIS Penfield Dissector delivers excellent durability, corrosion resistance, and dependable long-term performance. The satin low-glare finish minimizes reflections under operating microscopes and surgical lighting while facilitating efficient cleaning and maintenance. Widely used in hospitals, spine centers, and teaching institutions, this instrument is an essential component of minimally invasive spine surgery instrument sets. Fully reusable and autoclavable, the MIS Penfield Dissector – Pull, 10 5/8″, #4, 4 mm, Curved Down, Panther is designed to withstand repeated sterilization cycles while maintaining structural integrity, tip precision, and consistent performance. Common Clinical Applications Include: Minimally Invasive Spine Surgery (MISS) Lumbar Decompression Procedures Cervical Spine Surgery Microdiscectomy Laminectomy Foraminotomy Nerve Root Mobilization Epidural Tissue Dissection Neural Structure Retraction Educational and Training Applications Specifications Feature Details Product Name MIS Penfield Dissector – Pull, 10 5/8″, #4, 4 mm, Curved Down, Panther Instrument Type Minimally Invasive Penfield Dissector Function Tissue Dissection and Neural Structure Manipulation Pattern Penfield No. 4 Tip Size 4 mm Tip Configuration Curved Down Design Pull Style Handle Type Panther Handle Overall Length 10 5/8 in (approximately 27 cm) Application Minimally Invasive Spine Surgery Material Surgical-Grade Stainless Steel Finish Satin Low-Glare Finish Sterilization Fully Sterilizable and Autoclavable Reusability Reusable Frequently Asked Questions What is the MIS Penfield Dissector – Pull, 10 5/8″, #4, 4 mm, Curved Down, Panther used for? It is used for tissue dissection, nerve root mobilization, and controlled manipulation of neural structures during minimally invasive spine procedures. What are the advantages of the curved-down tip? The curved-down configuration improves access and visualization while facilitating precise dissection beneath neural structures. What is the benefit of the 4 mm Penfield No. 4 tip? The 4 mm tip provides a larger working surface for efficient tissue mobilization and controlled retraction. What is the purpose of the Panther handle? The Panther handle enhances ergonomics, provides a secure grip, and improves tactile feedback during minimally invasive procedures. Why is the 10 5/8-inch length important? The extended length allows effective use through tubular retractors and narrow surgical access channels. Is this instrument reusable? Yes. It is fully reusable and designed to withstand repeated cleaning and sterilization cycles. Is the MIS Penfield Dissector autoclavable? Yes. The instrument is fully autoclavable and suitable for standard hospital sterilization protocols.
| Instrument name | MIS Penfield Dissector – pull 10 5/8″ #4 4mm curved down Panther |
|---|---|
| Catalogue reference | US-38292 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.