General Surgery Instruments

Osher Universal Corneal Scissors

Catalogue reference: US-56959

$80.00$56.00✓ In Stock

The Osher Universal Corneal Scissors is a precision ophthalmic microsurgical instrument designed for controlled cutting and dissection of delicate corneal tissue. Its fine working profile supports accurate tissue trimming and manipulation during keratoplasty and other corneal surgical procedures.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The Osher Universal Corneal Scissors is a specialized ophthalmic microsurgical instrument designed for precise cutting, trimming, and dissection of corneal tissue during delicate eye procedures. Corneal surgery requires highly controlled instruments because the tissue is thin, transparent, and structurally delicate. A dedicated pair of corneal scissors provides the surgeon with accurate cutting capability while working under an operating microscope. The fine blades of the Osher Universal Corneal Scissors are designed to provide controlled tissue cutting with minimal unnecessary movement. The exact blade configuration, curvature, length, and tip geometry may vary according to the manufacturer and specific model. These characteristics should be verified before purchase to ensure that the instrument matches the surgeon’s preferred technique and intended application. Corneal scissors may be used during a range of ophthalmic procedures, including selected keratoplasty, corneal transplantation, corneal reconstruction, and anterior segment surgical techniques . Depending on the procedure, the scissors may assist with trimming graft tissue, cutting corneal tissue, or performing controlled dissection. The specific use should always be determined by a qualified ophthalmic surgeon. The universal design is intended to provide versatility across appropriate corneal surgical applications. A well-designed microsurgical scissor should provide smooth blade movement, accurate blade alignment, and controlled cutting action. These characteristics are particularly important when working around delicate corneal structures where excessive force or inaccurate cutting may compromise the surgical field. The handles are designed to provide controlled finger positioning and precise opening and closing of the blades. Ophthalmic microsurgery commonly requires extremely small movements, so a balanced instrument can help the surgeon maintain tactile feedback and make fine adjustments. The shaft should provide sufficient rigidity to transmit the surgeon’s hand movement accurately to the cutting blades. The Osher Universal Corneal Scissors can be incorporated into specialized ophthalmic instrument sets alongside corneal forceps, transplantation fixation forceps, trephines, corneal markers, spatulas, needle holders, speculums, and other microsurgical instruments. It may be suitable for ophthalmic operating rooms, corneal transplant centers, cataract and anterior segment facilities, and specialist eye-care practices. Precision manufacturing is essential for maintaining reliable cutting performance. The blades should meet correctly and maintain a sharp, appropriately finished cutting edge. Excessive blade separation, misalignment, corrosion, or damage can affect cutting precision. The instrument should therefore be inspected carefully before each clinical use. Reusable ophthalmic scissors are commonly manufactured from surgical-grade stainless steel or another appropriate medical-grade alloy. Stainless steel offers strength, corrosion resistance, dimensional stability, and compatibility with validated cleaning and sterilization processes. The exact material, blade configuration, cutting length, and finish should be confirmed from the manufacturer’s product documentation. After use, the scissors should be cleaned promptly according to the manufacturer’s validated instructions. The blades should be opened appropriately during cleaning so accessible surfaces can be thoroughly processed. Particular care should be taken around the blade junction and pivot area, where biological material may accumulate. Before sterilization and reuse, the Osher Universal Corneal Scissors should be inspected for smooth blade movement, correct alignment, corrosion, blade damage, and other abnormalities. The cutting edges should remain appropriately formed and free from nicks or deformation. Instruments with damaged blades should be removed from service and evaluated according to the facility’s instrument-maintenance procedures. Sterilization should be performed using a validated process compatible with the instrument’s material and manufacturer’s instructions. Steam sterilization may be appropriate for compatible reusable stainless-steel ophthalmic scissors, but the exact processing requirements and sterilization cycle should be confirmed from the applicable instructions for use. The Osher Universal Corneal Scissors combines precision cutting capability with a controlled microsurgical design, making it a useful instrument for corneal tissue management during keratoplasty, transplantation, and other specialized ophthalmic procedures. Key Features Osher-style universal corneal scissors Designed for precise corneal tissue cutting Suitable for delicate ophthalmic microsurgery Supports corneal trimming and controlled dissection Useful for selected keratoplasty procedures Suitable for corneal transplantation applications Fine blades provide controlled cutting action Balanced handle supports precise finger control Durable surgical-grade construction Reusable when supplied as a reusable instrument Requires inspection of blade alignment and cutting edges before use Suitable for validated cleaning and sterilization procedures when manufacturer-approved Product Specifications Specification Details Product Name Osher Universal Corneal Scissors Instrument Type Ophthalmic Microsurgical Scissors Primary Specialty Ophthalmology / Corneal Surgery Primary Function Corneal Tissue Cutting and Dissection Surgical Applications Keratoplasty, Corneal Transplantation, Microsurgery Blade Type Precision Corneal Scissor Blades Design Osher Universal Type Working Area Corneal Tissue Construction Precision Microsurgical Instrument Material Surgical-grade stainless steel or equivalent; confirm manufacturer specification Reusable Yes, when supplied as reusable Sterilization According to manufacturer-approved protocol Intended Users Qualified Ophthalmic Surgeons Packaging Individual instrument packaging unless otherwise specified FAQs 1. What are Osher Universal Corneal Scissors used for? Osher Universal Corneal Scissors are designed for precise cutting, trimming, and controlled dissection of corneal tissue during selected ophthalmic surgical procedures. 2. Can these scissors be used for corneal transplantation? Yes. Specialized corneal scissors may be used for selected tissue-cutting and graft-trimming steps during corneal transplantation and keratoplasty. 3. What makes corneal scissors different from standard surgical scissors? Corneal scissors feature fine, precision-manufactured blades designed for delicate ophthalmic tissue and controlled cutting under surgical magnification. 4. Can Osher Universal Corneal Scissors be used for keratoplasty? Yes. They can be included in appropriate keratoplasty instrument sets for controlled corneal tissue cutting and trimming according to the surgeon’s technique. 5. Are Osher Universal Corneal Scissors reusable? If supplied as a reusable surgical instrument, they can be cleaned and sterilized according to the manufacturer’s validated instructions and the healthcare facility’s reprocessing protocol. 6. What material are Osher Corneal Scissors made from? Reusable ophthalmic scissors are commonly manufactured from surgical-grade stainless steel or another suitable medical-grade alloy. The exact material should be confirmed with the supplier. 7. How should corneal scissors be sterilized? The scissors should be cleaned and sterilized according to the manufacturer’s validated instructions. Steam sterilization may be suitable for compatible reusable stainless-steel models.

Instrument nameOsher Universal Corneal Scissors
Catalogue referenceUS-56959
CategoryGeneral Surgery Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image