

Catalogue reference: US-59738
The S Artery Clamp 0.6–1.5mm Frame Double is a specialized small-vessel surgical instrument designed for controlled clamping of appropriately sized vascular structures. Its 0.6–1.5mm range and double-frame configuration make it suitable for selected microsurgical and delicate vascular applications.
Prefer Wise or bank transfer? Choose it at checkout.
The S Artery Clamp 0.6 1.5mm Frame Double is a specialized small-vessel artery clamp designed for controlled temporary clamping and manipulation of appropriately sized blood vessels during selected microsurgical, vascular, and reconstructive procedures. Its specified 0.6–1.5mm vessel range and double-frame configuration provide a dedicated option for delicate vascular applications requiring precise instrument positioning and controlled handling. Artery clamps are specialized surgical instruments used when temporary vascular control is required during an appropriate surgical procedure. A suitably selected clamp can provide localized occlusion or stabilization of a vessel while the surgical professional performs the intended intervention. Vessel selection, placement, application force, and duration should always be determined by a qualified surgical professional according to patient anatomy and established surgical technique. The 0.6–1.5mm vessel range is a key specification of this model. It provides a clear reference when selecting a clamp for appropriately sized small blood vessels. Correct sizing is particularly important in microsurgery because small vascular structures require careful manipulation and an instrument appropriate to their dimensions. The double-frame configuration provides a specialized structural arrangement for controlled instrument positioning. This configuration can support precise handling in delicate operative fields where accurate placement and maneuverability are important. The clamp should always be used according to its intended design and established clinical technique. The S Artery Clamp can be incorporated into microsurgical instrument sets, small-vessel repair trays, vascular reconstruction sets, reconstructive surgery collections, and specialty vascular instrument systems . It can complement micro forceps, microsurgical scissors, fine needle holders, vessel dilators, vascular bulldog clamps, and other precision surgical instruments. Its defined vessel range also makes the clamp useful for organizing specialized vascular instrument collections. Hospitals and surgical centers may maintain multiple artery clamp sizes to accommodate different vessel dimensions and procedural requirements. The 0.6–1.5mm specification provides a dedicated option for appropriately sized small-vessel applications. Controlled application is essential when working with small blood vessels. Excessive compression, improper positioning, or prolonged application can potentially cause vascular or surrounding tissue injury. This instrument should therefore only be used on appropriate anatomical structures by trained surgical professionals using controlled force and established surgical protocols. The compact configuration can be useful in restricted operative fields where the surgical team requires precise manipulation of small anatomical structures. A dedicated small-vessel clamp can help support appropriate instrument selection instead of using a larger general-purpose vascular clamp. Before every procedure, the S Artery Clamp should be carefully inspected for correct alignment, smooth mechanical operation, structural integrity, and condition of the working components. The double frame and clamping surfaces should remain properly aligned and free from deformation, excessive wear, corrosion, or visible damage. For reusable configurations, the instrument should be cleaned and decontaminated promptly after each procedure according to validated healthcare-facility instrument-processing procedures. Particular attention should be given to the frame, working surfaces, joints, and other areas where biological material may accumulate. Following cleaning, the clamp should be inspected again for proper mechanical function and structural condition. Sterilization should be performed using a validated method compatible with the instrument and consistent with applicable manufacturer instructions and institutional protocols. Proper cleaning, sterilization, handling, and storage help preserve instrument integrity and service life. For hospitals, vascular surgeons, microsurgeons, reconstructive surgical teams, operating rooms, surgical centers, and medical instrument suppliers, the S Artery Clamp 0.6–1.5mm Double Frame provides a specialized solution for controlled clamping of appropriately sized small blood vessels. Its defined vessel range and double-frame configuration make it a practical addition to professional microsurgical and vascular instrument collections. Key Features S Artery Clamp configuration Designed for small-vessel applications Specified 0.6–1.5mm vessel range Double-frame configuration Suitable for appropriate microsurgical procedures Designed for controlled temporary vascular clamping Supports precise positioning of suitable vascular structures Compact configuration for delicate operative fields Suitable for vascular and reconstructive surgery sets Designed for professional microsurgical environments Specialized option for small-vessel instrument collections Requires proper cleaning, inspection, sterilization, and storage Product Specifications Specification Details Product Name S Artery Clamp Instrument Type Small-Vessel Artery Clamp Vessel Range 0.6–1.5mm Frame Configuration Double Primary Application Microsurgery Secondary Applications Vascular & Reconstructive Surgery Intended Use Controlled Small-Vessel Clamping Working Configuration Double Frame Operation Manual Construction Surgical Instrument Sterilization According to validated facility protocol and manufacturer guidance Intended Users Trained Surgical Professionals Clinical Environment Hospitals, Operating Rooms & Surgical Centers FAQs 1. What is the S Artery Clamp used for? The S Artery Clamp is designed for controlled temporary clamping and manipulation of appropriately sized small blood vessels during selected microsurgical and vascular procedures. 2. What vessel size is this S Artery Clamp designed for? This model is specified for a 0.6–1.5mm vessel range , making it suitable for appropriately sized small-vessel applications. 3. What does Double Frame mean? Double Frame identifies the structural configuration of the instrument, providing a specialized frame design for controlled positioning during delicate vascular procedures. 4. Is this artery clamp suitable for microsurgery? Yes. Its 0.6–1.5mm vessel range and double-frame configuration make it suitable for appropriate small-vessel microsurgical applications. 5. Why is correct clamp sizing important? Selecting a clamp appropriate to the target vessel can support controlled vascular handling and help minimize unnecessary compression or manipulation. 6. How should the S Artery Clamp be sterilized? For reusable configurations, it should be cleaned, decontaminated, inspected, and sterilized using a validated process consistent with manufacturer guidance and healthcare-facility protocols. 7. How should the double-frame artery clamp be maintained? The frame, working surfaces, alignment, and mechanical components should be inspected after cleaning and before reuse for proper function, deformation, wear, or visible damage.
| Instrument name | S Artery Clamp 0.6 1.5mm Frame Double |
|---|---|
| Catalogue reference | US-59738 |
| Category | General Surgery Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.