

Catalogue reference: US-89629
The 26mm Mueller Type Femoral Head Dislocation Lever is an orthopedic hip instrument designed to assist with controlled manipulation and dislocation of the femoral head during hip procedures. Its lever-style design provides controlled mechanical leverage while working around the hip joint.
Prefer Wise or bank transfer? Choose it at checkout.
The Femoral Head Dislocation Lever 26mm Mueller Type is a specialized orthopedic instrument designed to assist surgeons with controlled manipulation of the femoral head during hip surgery. Its Mueller-type configuration provides a dedicated working profile for applying controlled leverage during procedures where femoral head exposure or dislocation is required. The instrument features a 26mm working end , providing a defined contact surface for engagement with compatible anatomical structures. The lever design allows the surgeon to apply controlled mechanical force while maintaining instrument handling and positioning throughout the procedure. Femoral head dislocation instruments are commonly used during hip arthroplasty and other orthopedic hip procedures where access to the femoral head and acetabular region is required. By providing controlled leverage, the instrument can assist with positioning and exposure according to the surgeon’s selected operative technique. The Mueller-type design is associated with orthopedic hip instrumentation and is intended for professional surgical environments. Its ergonomic configuration allows the instrument to be positioned and manipulated with appropriate control during operative use. Commonly manufactured from surgical-grade stainless steel or another suitable medical-grade alloy , the instrument is designed for durability, corrosion resistance, and reliable performance when properly maintained. The working end should be inspected before use to ensure that its surface, alignment, and structural integrity remain suitable for the intended application. This instrument should only be used by appropriately trained healthcare professionals and in accordance with the applicable surgical technique. If supplied as a reusable surgical instrument, cleaning, disinfection, inspection, packaging, and sterilization should be performed according to the manufacturer’s validated reprocessing instructions and institutional protocols. Key Features Mueller-type femoral head dislocation lever 26mm working end Designed for controlled femoral head manipulation Provides mechanical leverage during hip procedures Useful for femoral head exposure and dislocation Suitable for orthopedic hip surgery Commonly used in hip arthroplasty procedures Designed for controlled instrument positioning Durable surgical-grade construction Suitable for professional orthopedic environments Reusable when specifically manufactured and validated for reuse Designed for compatibility with appropriate surgical techniques Product Specifications Specification Details Product Type Femoral Head Dislocation Lever Pattern Mueller Type Working End 26mm Primary Function Femoral Head Manipulation & Dislocation Application Orthopedic Hip Surgery Common Use Hip Arthroplasty & Femoral Head Exposure Construction Surgical-Grade Stainless Steel / Medical-Grade Alloy Instrument Category Orthopedic Surgical Instrument Reusable Yes, when specifically designed and validated for reuse Sterilization According to validated manufacturer instructions Frequently Asked Questions What is a Femoral Head Dislocation Lever used for? It is designed to assist with controlled manipulation and dislocation of the femoral head during appropriate orthopedic hip procedures. What does Mueller Type mean? Mueller Type identifies the instrument’s established orthopedic design pattern, commonly associated with hip surgical instrumentation. What is the working size of this instrument? This model has a 26mm working end . Can it be used during hip replacement surgery? It may be used during appropriate hip arthroplasty procedures when femoral head manipulation or exposure is required and the instrument is compatible with the surgical technique. What is the primary function of the lever design? The lever design provides controlled mechanical leverage to assist with manipulation of the femoral head and related structures. What material is it commonly made from? It is commonly manufactured from surgical-grade stainless steel or another suitable medical-grade alloy. Is this instrument reusable? It can be reusable when specifically designed and validated for reusable surgical use. Always follow the manufacturer’s reprocessing instructions. How should it be sterilized? Reusable instruments should be cleaned, inspected, packaged, and sterilized according to validated manufacturer instructions and applicable healthcare facility protocols.
| Instrument name | Femoral Head Dislocation Lever 26mm Mueller Type Orthopedic Hip Instrument |
|---|---|
| Catalogue reference | US-89629 |
| Category | Hip Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.