Orthopaedic Instruments

7″ Cushing IVD Rongeur – 2x10mm, Up, Panther Coated

Catalogue reference: US-45590

$180.00$126.00✓ In Stock

The 7″ Cushing IVD Rongeur – 2x10mm Up Panther Coated is a precision spinal surgical instrument designed for controlled removal of intervertebral disc material. Its compact 7-inch design and upward angled jaws provide excellent access in confined surgical fields. The Panther coating enhances durability, corrosion resistance, and long-term performance.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 7″ Cushing IVD Rongeur – 2x10mm Up Panther Coated is a specialized surgical instrument designed for precise and controlled removal of intervertebral disc (IVD) material and small bone fragments during spinal procedures. It is widely used in orthopedic spine surgery, neurosurgery, and minimally invasive spinal decompression procedures where accuracy, control, and reduced tissue trauma are essential for successful outcomes. This instrument features a 2x10mm upward-angled jaw configuration, engineered to provide superior access to elevated anatomical regions within the spinal column. The upward angle allows surgeons to reach superior disc spaces with improved visualization and precision, particularly in posterior spinal approaches where access and angulation are critical for safe and effective bone removal. The compact 7-inch (approximately 175mm) design makes this Cushing IVD Rongeur highly maneuverable, especially in minimally invasive surgical environments or narrow operative fields. Its shorter length provides enhanced control and reduces hand fatigue, enabling surgeons to perform delicate procedures with greater stability and accuracy. A key feature of this model is its Panther Coated surface finish, which significantly enhances instrument durability and performance. The specialized coating provides superior resistance to corrosion, wear, and repeated autoclave sterilization cycles. It also reduces surface friction, ensuring smoother jaw movement and improved cutting efficiency during surgery. Manufactured from high-quality surgical-grade stainless steel, the instrument offers excellent strength, reliability, and long-term clinical performance. The combination of stainless steel construction and Panther coating ensures optimal structural integrity even under demanding surgical conditions. The precision-machined jaws are designed for clean and controlled cutting action. The 2x10mm bite capacity allows efficient removal of disc tissue while minimizing trauma to surrounding neural structures, including nerve roots and spinal cord tissue. This controlled cutting mechanism enhances surgical safety and improves procedural precision. Ergonomically designed handles provide a secure and comfortable grip, reducing surgeon fatigue during extended procedures. The lightweight 7-inch structure combined with balanced weight distribution enhances tactile feedback and control. The smooth ratchet mechanism ensures consistent bite force, allowing for predictable and precise tissue removal. The 7″ Cushing IVD Rongeur – 2x10mm Up Panther Coated is commonly used in lumbar and cervical spine surgeries, including discectomy, laminotomy, and spinal decompression procedures. It is particularly effective in removing herniated or degenerated intervertebral disc material that may compress spinal nerves and cause pain or neurological deficits. Its Panther Coated finish not only improves durability but also simplifies cleaning and maintenance, ensuring compliance with strict surgical sterilization protocols. The instrument is fully reusable and designed for long-term use in high-volume surgical environments. In modern spinal surgery, precision and reliability are essential. This instrument provides surgeons with enhanced control, improved access, and superior durability, making it a valuable tool for advanced spinal procedures and minimally invasive techniques. Key Features 2x10mm upward-angled jaws for superior spinal access Compact 7″ design for enhanced maneuverability Panther Coated surface for improved durability and performance High-grade surgical stainless steel construction Corrosion-resistant and wear-resistant finish Designed for intervertebral disc (IVD) removal procedures Fully autoclavable and reusable surgical instrument Precision-aligned jaws for controlled cutting action Reduced friction for smoother surgical performance Ergonomic handle reduces surgeon fatigue Ideal for minimally invasive spine surgery Reliable performance in high-precision neurosurgical procedures Product Specifications Table Specification Details Product Type Cushing IVD Rongeur Application Spinal, orthopedic, neurosurgical procedures Material Surgical Grade Stainless Steel Finish Panther Coated Surface Sterilization Autoclave Compatible Reusability Reusable Specialty Intervertebral disc removal instrument Instrument Type Rongeur Usage Disc and bone tissue excision Product Contents 1 x 7″ Cushing IVD Rongeur – 2x10mm Up Panther Coated Applications Lumbar discectomy procedures Cervical spine decompression surgery Minimally invasive spinal surgery Removal of herniated intervertebral disc material Spinal canal decompression procedures Orthopedic spine surgery Neurosurgical spinal interventions Posterior spinal approaches with limited access FAQs Q1: What is the 7″ Cushing IVD Rongeur used for? It is used for precise removal of intervertebral disc material and small bone fragments during spinal surgery. Q2: What does the Panther coating do? The Panther coating improves corrosion resistance, durability, and reduces friction for smoother surgical performance. Q3: Why is the 7-inch size important? The compact size allows better maneuverability and control in minimally invasive and confined surgical spaces. Q4: What does the 2x10mm jaw size indicate? It refers to the cutting capacity, allowing controlled and precise removal of disc tissue. Q5: Is the instrument reusable and sterilizable? Yes, it is fully autoclavable and designed for repeated surgical sterilization cycles. Q6: What surgeries commonly use this instrument? It is commonly used in discectomy, spinal decompression, and neurosurgical spinal procedures.

Instrument name7″ Cushing IVD Rongeur – 2x10mm, Up, Panther Coated
Catalogue referenceUS-45590
CategoryOrthopaedic Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image