

Catalogue reference: US-51801
The Anderson Neivert Osteotome – 4mm Curved Cutting Edge, Left Single Guard, 205mm is a precision ENT surgical instrument designed for controlled bone cutting. Its curved blade ensures accuracy in confined anatomical spaces. Ideal for nasal and facial reconstructive procedures.
Prefer Wise or bank transfer? Choose it at checkout.
The Anderson Neivert Osteotome – 4mm Curved Cutting Edge, Left Single Guard, 205mm is a specialized ENT and facial surgical instrument designed for precise and controlled cutting of bone during reconstructive and corrective procedures. It is widely used in rhinoplasty, septoplasty, and other maxillofacial surgeries where accuracy, stability, and minimal tissue disruption are essential for optimal surgical outcomes. Manufactured from premium surgical-grade stainless steel, this osteotome ensures excellent durability, corrosion resistance, and long-term reliability. Its robust construction allows it to withstand repeated sterilization cycles without compromising structural integrity or sharpness, making it suitable for continuous use in demanding surgical environments. The instrument features a 4mm curved cutting edge designed to provide controlled and precise bone shaping. The curved profile allows surgeons to navigate anatomical contours more effectively, especially in confined or angled surgical fields where straight instruments may be less effective. The left single guard enhances safety by protecting surrounding soft tissues during bone cutting procedures. This feature helps reduce the risk of accidental injury while ensuring that cutting force is directed precisely onto the target bone structure. With a length of 205mm, the Anderson Neivert Osteotome provides excellent reach and control during surgical procedures. The extended shaft allows surgeons to maintain stability and precision even in deeper or less accessible anatomical regions. The ergonomic handle design ensures a secure and comfortable grip, improving surgical control and reducing hand fatigue during prolonged procedures. This enhances accuracy and efficiency, particularly in delicate reconstructive surgeries. The polished stainless steel finish ensures smooth handling, resistance to corrosion, and easy cleaning. The instrument is fully autoclavable, allowing safe and repeated sterilization while maintaining hygiene and performance standards required in modern surgical practice. The Anderson Neivert Osteotome is commonly used in ENT and maxillofacial procedures such as rhinoplasty, septoplasty, nasal bone reshaping, and facial reconstructive surgery. It is particularly effective in controlled osteotomy procedures where precision bone cutting is required. Designed for ENT surgeons and facial plastic surgeons, this instrument meets strict medical standards for safety, reliability, and surgical precision. Its combination of curved cutting edge, protective guard, and durable stainless steel construction makes it an essential tool in modern nasal and facial surgery. Whether used for nasal reconstruction or facial bone contouring, the Anderson Neivert Osteotome delivers consistent performance, enhanced control, and superior surgical accuracy. Key Features 4mm curved cutting edge for precise bone cutting Left single guard for enhanced tissue protection 205mm length for deep surgical access and control Made from high-quality surgical-grade stainless steel Corrosion-resistant and highly durable construction Autoclavable and suitable for repeated sterilization cycles Ideal for ENT and maxillofacial procedures Ensures controlled and accurate osteotomy cuts Ergonomic handle reduces surgeon fatigue Smooth polished finish for easy cleaning Suitable for nasal and facial bone surgery Provides excellent stability during delicate procedures Product Specifications Table Specification Details Product Type Osteotome Application ENT / Maxillofacial Surgery Material Surgical Grade Stainless Steel Finish Mirror Polished Sterilization Autoclave Safe Reusability Reusable Specialty Bone Cutting / Osteotomy Instrument Type Anderson Neivert Osteotome Usage Controlled bone cutting in nasal and facial surgery Product Contents 1 x Anderson Neivert Osteotome (4mm Curved, Left Guard, 205mm) Applications The Anderson Neivert Osteotome is used in: Rhinoplasty procedures Septoplasty surgeries Nasal bone reshaping Facial reconstructive surgery Maxillofacial osteotomy procedures ENT bone contouring procedures Traumatic nasal fracture correction Cosmetic nasal surgery FAQs Q1: What is the Anderson Neivert Osteotome used for? A: It is used for precise bone cutting and shaping in ENT and facial surgical procedures. Q2: What is the purpose of the curved cutting edge? A: The curved edge allows better adaptation to anatomical contours for controlled bone cutting. Q3: What does the left single guard do? A: It protects surrounding soft tissues during osteotomy procedures. Q4: Is this instrument reusable? A: Yes, it is made from surgical-grade stainless steel and is fully reusable after sterilization. Q5: Can it be autoclaved? A: Yes, it is fully autoclavable and designed for repeated sterilization cycles. Q6: In which surgeries is it commonly used? A: It is commonly used in rhinoplasty, septoplasty, and facial reconstructive surgeries.
| Instrument name | Anderson Neivert Osteotome – 4mm Curved Cutting Edge, Left Single Guard, 205mm |
|---|---|
| Catalogue reference | US-51801 |
| Category | Orthopaedic Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.