Surgical Instruments

6″ Thompson Carotid Clamp Curved Shanks

Catalogue reference: US-57522

$80.00$56.00✓ In Stock

The 6″ Thompson Carotid Clamp Curved Shanks is a specialized vascular surgical instrument designed for controlled handling and temporary management of appropriately sized carotid vascular structures. Its curved shanks provide an offset approach that can facilitate access in selected carotid and vascular procedures.

Prefer Wise or bank transfer? Choose it at checkout.

Guaranteed Safe & Secure Checkout
VisaMastercardAmerican ExpressBank TransferWise
✓ German Grade DIN Steel
✓ 100% Autoclave Tested
✓ ISO 13485 & CE Mark
✓ 30-Day Hospital Return

The 6″ Thompson Carotid Clamp Curved Shanks is a specialized cardiovascular and vascular surgical instrument designed to assist with controlled manipulation, positioning, isolation, and temporary occlusion of appropriately sized carotid and vascular structures. Measuring 6 inches overall, this clamp features curved shanks that provide an offset working trajectory for selected vascular procedures. The Thompson Carotid Clamp is intended for applications where controlled access to carotid vessels is required. Its specialized configuration can assist with vessel positioning, isolation, manipulation, and temporary occlusion during selected vascular and cardiovascular procedures. The exact clinical indication and method of use should always be determined by a qualified vascular or cardiovascular surgeon. The curved shanks create an offset between the handles and working end, allowing the instrument to approach selected vascular structures from a suitable direction. This configuration can be useful when surrounding anatomy or surgical exposure makes a straight approach less convenient. The curved profile may also provide additional hand clearance around the operative field. At 6 inches overall length , the clamp provides useful working reach while retaining practical maneuverability. This moderate length can support controlled handling during carotid and other peripheral vascular procedures where precise positioning is important. The Thompson Carotid Clamp may be incorporated into professional vascular, cardiovascular, carotid, and thoracic surgical instrument sets . Depending on the exact working-end configuration, potential applications include temporary vascular occlusion, vessel isolation, positioning, manipulation, and selected vascular repair procedures. Proper instrument selection is essential when working with carotid and other vascular structures. Vessel dimensions, anatomical location, tissue characteristics, surgical exposure, and procedural requirements should be considered before selecting the clamp. The exact jaw dimensions and working-end specifications should be verified against the manufacturer’s technical documentation. Controlled application is particularly important when handling vascular tissue. The working end should be positioned accurately before application, and only the force necessary for the intended clinical purpose should be used. Excessive compression, twisting, bending, or inappropriate leverage should be avoided to help minimize potential tissue trauma. The curved-shank design can provide improved access around selected vascular anatomy while allowing the surgeon to maintain a practical hand position. This may be advantageous in operative fields where direct access is restricted or where additional clearance around the surgical site is desirable. The instrument is typically manufactured from surgical-grade stainless steel , providing mechanical strength, durability, and corrosion resistance suitable for professional reusable surgical instrumentation. Precision manufacturing supports reliable alignment and consistent mechanical performance. A smooth finish also facilitates routine cleaning, inspection, and maintenance. After use, reusable instruments should be promptly cleaned and decontaminated according to established healthcare-facility procedures. Particular attention should be given to the working end, curved shanks, hinge, and adjoining surfaces , where blood and biological residue may accumulate. The clamp should be inspected for corrosion, wear, deformation, surface damage, and proper alignment before sterilization. Sterilization should be performed using a validated process compatible with the manufacturer’s instructions and institutional infection-control requirements. Proper handling and storage help preserve the curved-shank configuration and mechanical performance. The 6″ Thompson Carotid Clamp Curved Shanks combines a 6-inch overall length with curved shanks for controlled access and manipulation of appropriately selected carotid and vascular structures. Its specialized geometry, practical reach, and durable construction make it a useful addition to professional vascular surgical instrument sets. Key Features Thompson Carotid Clamp design 6-inch overall length Curved shank configuration Offset working trajectory Designed for selected carotid vascular procedures Supports controlled temporary vessel occlusion Facilitates vessel positioning and isolation Useful for controlled vascular manipulation Provides practical hand clearance Suitable for cardiovascular and vascular surgery Surgical-grade stainless steel construction Durable design for professional reusable instrumentation Product Specifications Specification Details Product Name Thompson Carotid Clamp Overall Length 6″ Shank Configuration Curved Instrument Type Carotid / Vascular Clamp Primary Function Vessel manipulation, positioning, isolation, and temporary occlusion Intended Application Appropriately sized carotid and vascular structures Surgical Specialty Vascular / Cardiovascular Surgery Typical Application Carotid vessel control, positioning, isolation, and manipulation Working Profile Curved shanks Material Surgical-grade stainless steel Reusable Yes, for reusable models Sterilization Follow validated manufacturer and facility protocols FAQs 1. What is the Thompson Carotid Clamp used for? It is designed to assist with controlled manipulation, positioning, isolation, and temporary occlusion of appropriately sized carotid and vascular structures. 2. What is the overall length of this clamp? The overall length is 6 inches . 3. What is the benefit of curved shanks? Curved shanks provide an offset approach that can facilitate access around selected vascular structures and provide additional hand clearance. 4. Is this clamp designed for carotid procedures? Yes. Its specialized pattern is intended for selected procedures involving appropriately sized carotid vascular structures. 5. Can it be used for temporary vascular occlusion? Yes. It can support temporary vessel occlusion when appropriately selected for the target anatomy and surgical technique. 6. Which specialties may use this instrument? It may be incorporated into selected vascular, cardiovascular, carotid, and thoracic surgical instrument sets. 7. What material is the Thompson Carotid Clamp made from? It is typically manufactured from surgical-grade stainless steel for strength, durability, and corrosion resistance. 8. How should this carotid clamp be sterilized? Reusable models should be cleaned, inspected, and sterilized using a validated process according to the manufacturer’s instructions and healthcare-facility sterilization protocols.

Instrument name6″ Thompson Carotid Clamp Curved Shanks
Catalogue referenceUS-57522
CategorySurgical Instruments

Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.

Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.

Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.

Read the shipping and return policy

Instrument Specifications

Chat with Export Sales
Full Product Image