Catalogue reference: US-24286
Trocar Cannula System is a precision ophthalmic access device designed to create and maintain self-sealing entry ports during vitreoretinal surgery. Consisting of a sharp trocar obturator and a matching cannula sleeve, this reusable or single-use system provides secure transconjunctival access, stable instrument entry, and efficient fluid management during posterior segment procedures.
Prefer Wise or bank transfer? Choose it at checkout.
Trocar Cannula System is a specialized ophthalmic surgical access system used during pars plana vitrectomy (PPV) and other vitreoretinal procedures to establish minimally invasive entry ports into the eye. The system typically consists of a sharp trocar blade or obturator housed within a precision-engineered cannula sleeve . During insertion, the trocar creates a controlled scleral entry pathway, and once positioned, the trocar is removed, leaving the cannula in place as a stable access port for surgical instruments. Designed for modern microincision vitreoretinal surgery (MIVS), the Trocar Cannula System facilitates repeated instrument exchanges while helping maintain intraocular pressure and minimizing trauma to surrounding tissues. The cannula serves as a protected pathway for vitreoretinal instruments such as vitrectomy probes, illumination probes, infusion cannulas, membrane peeling forceps, laser probes, scissors, and aspiration instruments. This allows efficient surgical workflow while preserving the integrity of the scleral incision. The low-profile design supports self-sealing wound architecture and contributes to reduced tissue disruption compared with traditional larger-gauge surgical approaches. The system helps maintain a stable surgical environment throughout the procedure. Trocar Cannula Systems are routinely used during retinal detachment repair, pars plana vitrectomy, diabetic vitreoretinal surgery, macular surgery, membrane peeling procedures, vitreous hemorrhage management, endolaser treatment, and posterior segment reconstruction. Manufactured from high-quality surgical-grade materials, the system provides dependable performance, precise fit, and secure instrument passage. Depending on the configuration, systems may be supplied as sterile single-use devices or reusable components. Available in multiple gauge sizes, including microincision vitreoretinal surgery platforms, Trocar Cannula Systems can be selected according to surgical technique and surgeon preference. Widely used in hospitals, ophthalmic surgery centers, retinal specialty clinics, and ambulatory surgical facilities, the Trocar Cannula System is a fundamental component of modern vitreoretinal surgery. Common Clinical Applications Pars Plana Vitrectomy (PPV) Retinal Detachment Repair Diabetic Vitreoretinal Surgery Macular Surgery Membrane Peeling Procedures Vitreous Hemorrhage Management Endolaser Treatment Fluid-Air Exchange Posterior Segment Reconstruction Microincision Vitreoretinal Surgery (MIVS) Specifications Feature Details Product Name Trocar Cannula System Instrument Type Ophthalmic Surgical Access System Function Creation and Maintenance of Vitreoretinal Access Ports Components Trocar Obturator and Cannula Sleeve Access Technique Transconjunctival Microincision Entry Application Area Posterior Segment Surgery Cannula Design Stable Instrument Access Port Available Gauges Multiple Gauge Sizes Available Material Surgical-Grade Stainless Steel and Medical-Grade Components Available Configurations Valved and Non-Valved Systems Available Sterilization Reusable or Single-Use Options Available Application Vitreoretinal Surgery Frequently Asked Questions What is a Trocar Cannula System used for? It is used to create and maintain surgical access ports during vitreoretinal procedures, allowing instruments to enter and exit the eye safely. What are the main components of the system? The system consists of a trocar used to create the entry pathway and a cannula that remains in place as the instrument access port. Which procedures commonly use a Trocar Cannula System? It is commonly used in pars plana vitrectomy, retinal detachment repair, diabetic vitreoretinal surgery, membrane peeling procedures, and macular surgery. Which medical specialties commonly use this instrument? It is primarily used in ophthalmology, particularly in vitreoretinal and retinal microsurgery. What is the advantage of a trocar cannula system? It facilitates minimally invasive access, supports repeated instrument exchanges, and helps maintain intraocular stability during surgery. Are different gauge sizes available? Yes. Trocar Cannula Systems are available in multiple gauge sizes and configurations to accommodate various vitreoretinal surgical techniques. Is the Trocar Cannula System reusable? Depending on the manufacturer and model, systems may be available in reusable or sterile single-use configurations.
| Instrument name | Trocar Cannula System |
|---|---|
| Catalogue reference | US-24286 |
| Category | Surgical Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.