Catalogue reference: US-26074
The Bhargava Modular Offset Cup Liner Impactor is a specialized orthopedic surgical instrument designed for accurate seating and alignment of acetabular cup liners during total hip arthroplasty (THA). It ensures stable and controlled impaction. Manufactured from premium surgical-grade stainless steel, it delivers durability, precision, and consistent performance in hip replacement procedures.
Prefer Wise or bank transfer? Choose it at checkout.
The Bhargava Modular Offset Cup Liner Impactor is a precision-engineered orthopedic surgical instrument designed for the accurate placement and secure impaction of acetabular cup liners during total hip arthroplasty (THA). It plays a critical role in ensuring proper alignment, seating, and stability of the liner within the acetabular shell. In hip replacement surgery, correct positioning of the cup liner is essential for joint stability, implant longevity, and optimal patient outcomes. The Bhargava Modular Offset Cup Liner Impactor is specifically designed to provide controlled force transmission, allowing surgeons to seat the liner precisely without damaging the implant surface or surrounding bone. The offset modular design of this impactor enhances surgical access in deep or constrained operative fields. It allows surgeons to achieve optimal angulation while maintaining a clear view of the acetabular component. This feature is particularly beneficial in minimally invasive and revision hip surgeries where space is limited. This instrument ensures uniform force distribution during impaction, reducing the risk of misalignment or improper seating of the liner. By improving accuracy, it helps prevent complications such as liner dislodgement, uneven wear, or implant instability. Manufactured from high-quality surgical-grade stainless steel, the Bhargava Cup Liner Impactor offers excellent strength, corrosion resistance, and long-term durability. It is designed to withstand repeated use in demanding orthopedic environments and multiple sterilization cycles without performance degradation. The polished surface finish ensures easy cleaning and full compliance with operating room sterilization standards. The instrument is fully autoclavable and reusable, making it a cost-effective and sustainable solution for orthopedic surgical centers. Its ergonomic handle design provides surgeons with a secure grip and enhanced control during impaction. The balanced structure reduces hand fatigue and allows precise application of force, improving surgical accuracy and efficiency. The Bhargava Modular Offset Cup Liner Impactor is widely used in primary total hip arthroplasty, revision hip replacement surgery, and complex acetabular reconstruction procedures. It is particularly valuable in cases requiring precise implant positioning in anatomically challenging situations. By ensuring accurate liner placement, this instrument contributes to improved joint stability, reduced wear, and better long-term outcomes for patients. It supports modern orthopedic techniques focused on precision implant alignment and minimally invasive surgery. Orthopedic surgeons rely on this impactor for its reliability, precision engineering, and ease of use in complex hip procedures. It is an essential component of advanced hip arthroplasty instrument sets. Overall, the Bhargava Modular Offset Cup Liner Impactor combines ergonomic design, durable stainless steel construction, and precise mechanical performance to deliver consistent results in acetabular liner implantation. Key Features Designed for acetabular cup liner impaction in THA Ensures accurate and stable liner seating Modular offset design for improved surgical access Provides controlled and uniform force transmission Reduces risk of implant misalignment Ideal for primary and revision hip arthroplasty Manufactured from surgical-grade stainless steel Corrosion-resistant and highly durable construction Ergonomic handle for secure grip and control Fully autoclavable and reusable instrument Suitable for minimally invasive hip surgery Enhances implant stability and surgical precision Product Specifications Specification Details Product Type Cup Liner Impactor Application Total Hip Arthroplasty (THA) Material Surgical Grade Stainless Steel Finish Polished / Satin Finish Sterilization Autoclavable Reusability Reusable Specialty Orthopedic Hip Surgery Instrument Type Implant Impaction Instrument Usage Acetabular Liner Placement Product Contents 1 × Bhargava Modular Offset Cup Liner Impactor Product Contents 1 × Bhargava Modular Offset Cup Liner Impactor Applications The Bhargava Cup Liner Impactor is commonly used in: Total hip arthroplasty (THA) Revision hip replacement surgery Acetabular reconstruction procedures Minimally invasive hip surgery Implant liner seating and alignment Orthopedic reconstructive hip procedures Complex acetabular component placement Surgical training and orthopedic education FAQs What is the Bhargava Cup Liner Impactor used for? It is used to accurately seat and align acetabular cup liners during hip replacement surgery. Why is the offset design important? The offset design improves access and visibility in deep or constrained surgical fields. Is it used in revision hip surgery? Yes, it is commonly used in both primary and revision THA procedures. What material is it made from? It is made from high-quality surgical-grade stainless steel. Can it be sterilized? Yes, it is fully autoclavable and reusable. Does it improve implant stability? Yes, it ensures precise liner placement, improving long-term implant stability. Is it suitable for minimally invasive surgery? Yes, its modular design supports minimally invasive hip approaches.
| Instrument name | Bhargava Modular Offset Cup Liner Impactor |
|---|---|
| Catalogue reference | US-26074 |
| Category | Hip Instruments |
Worldwide Hospital Handling: Orders are hand-calibrated, ultrasonically passivated to ASTM A967 standards, and dispatched within 24–48 hours directly from our own manufacturing facility. Priority air express delivery via DHL and FedEx includes complete Certificate of Conformity and material mill test documentation.
Autoclave Guarantee: 100% steam autoclave validated (134°C / 273°F). If any instrument exhibits pitting, jaw misalignment, or micro-structural defect, it is replaced unconditionally under our 30-Day Hospital Return & Exchange Guarantee.
Worldwide shipping is $50 USD per order below $500 USD, and free on orders of $500 USD or more. The final shipping charge is shown at checkout. Returns are accepted within 30 days of delivery for unused instruments in their original packaging.
Direct wholesale export quotes delivered to your email within 24 hours.